Effect of surface coating on the screw loosening of dental abutment screws

被引:0
|
作者
Chan-Ik Park
Han-Cheol Choe
Chae-Heon Chung
机构
[1] Chosun University,Department of Prosthodontics, College of Dentistry
[2] Chosun University,Department of Dental Materials & Research Center of Nano
来源
关键词
screw loosening; screw surface treatment; coated screw; scratch test;
D O I
暂无
中图分类号
学科分类号
摘要
Regardless of the type of performed restoration, in most cases, a screw connection is employed between the abutment and implant. For this reason, implant screw loosening has remained a problem in restorative practices. The purpose of this study was to compare the surface of coated/plated screws with titanium and gold alloy screws and to evaluate the physical properties of coated/plated material after scratch tests via FE-SEM (field emission scanning electron microscopy) investigation. GoldTite, titanium screws provided by 3i (Implant Innovation, USA) and TorqTite, titanium screws by Steri-Oss (Nobel Biocare, USA) and gold screws and titanium screws by AVANA (Osstem Implant, Korea) were selected for this study. The surface, crest, and root of the abutment screws were observed by FE-SEM. A micro-diamond needle was also prepared for the scratch test. Each abutment screw was fixed, and a scratch on the surface of the head region was made at constant load and thereafter the fine trace was observed with FE-SEM. The surface of GoldTite was smoother than that of other screws and it also had abundant ductility and malleability compared with titanium and gold screws. The scratch tests also revealed that teflon particles were exfoliated easily in the screw coated with teflon. The titanium screw had rough surface and low ductility. The clinical use of gold-plated screws is recommended as a means of preventing screw loosening.
引用
收藏
页码:549 / 553
页数:4
相关论文
共 50 条
  • [1] Effects of surface coating on the screw loosening of dental abutment screws
    Park, CI
    Choe, HC
    Chung, CH
    METALS AND MATERIALS INTERNATIONAL, 2004, 10 (06) : 549 - 553
  • [2] The Effect of Abutment Screw Length on Screw Loosening in Dental Implants with External Abutment Connections After Thermocycling
    Yeo, In-Sung
    Lee, Joo-Hee
    Kang, Tae-Joo
    Kim, Seong-Kyun
    Heo, Seong-Joo
    Koak, Jai-Young
    Park, Ji-Man
    Lee, Su-Young
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 59 - 62
  • [3] Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating
    Bacchi, Atais
    Regalin, Alexandre
    Brilhante Bhering, Claudia Lopes
    Alessandretti, Rodrigo
    Spazzin, Aloisio Oro
    JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (05): : 375 - 379
  • [4] Deformation of dental abutment screw after tightening and loosening
    Kim, Hee Jung
    Choe, Han Cheol
    Chung, Chae Heon
    Brantley, William
    MECHANICAL BEHAVIOR OF MATERIALS X, PTS 1AND 2, 2007, 345-346 : 13 - +
  • [5] A study on the abutment screw loosening phenomenon of dental implant
    Kang, YM
    Cho, IH
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1261 - 1261
  • [6] Antimicrobial profile of a dental implant abutment coating to prevent adhesion and migration of bacteria and screw loosening
    Rodrigues, M. A.
    Cortez, A. R.
    Cortez, J.
    Gobbo, P.
    Lepicka, M.
    Barros-Silva, S.
    Freitas, P. P.
    Lopes, M. A.
    Mendes, J.
    DENTAL MATERIALS, 2021, 37 (10) : E493 - E501
  • [7] Different Methods to Salvage the Fractured Abutment Screws and Potential Reasons of Abutment Screw Loosening: A Narrative Review
    Gir, Prajakta
    Joshi, Snehal
    Vishnupriya, V.
    Marathe, Ashlesha
    Bagul, Abhishek
    Nazirkar, Girish
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 5) : S4198 - S4200
  • [8] Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system
    Kitagawa, T
    Tanimoto, Y
    Odaki, M
    Nemoto, K
    Aida, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (02) : 457 - 463
  • [9] Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis
    Kim, Seok-Gyu
    Chung, Chae-Heon
    Son, Mee-Kyoung
    JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (03): : 207 - 213
  • [10] Effect of Screw Channel Angulation on Reverse Torque Values of Dental Implant Abutment Screws
    Hu, Eric
    Petrich, Anton
    Imamura, Glen
    Hamlin, Christopher
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (09): : 969 - 972