Ameliorated phase sensitivity through intensity measurements in a Mach–Zehnder interferometer

被引:0
|
作者
Jayanth Ramakrishnan
J. Solomon Ivan
机构
[1] Indian Institute of Space Science and Technology,Applied and Adaptive Optics laboratory Department of Physics
来源
关键词
Quantum metrology; Phase estimation; Intensity measurements; Quantum metrology; Mach-Zehnder interferometer;
D O I
暂无
中图分类号
学科分类号
摘要
The ultimate achievable phase sensitivity in a Mach–Zehnder interferometer is given by the Heisenberg limit of 1/⟨N⟩\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$1/\langle N\rangle $$\end{document}, with ⟨N⟩\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\langle N \rangle $$\end{document} being the number of photons in the interferometer. However, the best-known phase sensitivity as obtained through intensity measurements is ≈2/⟨N⟩\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\approx 2/\langle N \rangle $$\end{document}. In this work, we provide examples of states that achieve improved phase sensitivity lesser than 2/⟨N⟩\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$2/\langle N \rangle $$\end{document}, albeit greater than 1/⟨N⟩\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$1/\langle N \rangle $$\end{document}. A modified scheme of the Mach–Zehnder interferometer that uses the first excited Fock state, single-mode squeezers, and an additional beam splitter is presented. It is shown that the modified scheme attains a phase sensitivity lesser than 2/⟨N⟩\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$2/\langle N \rangle $$\end{document}, through intensity measurements. The effect of attenuation and noise on phase sensitivity is considered. Phase sensitivity superior to the standard quantum limit is seen to persist for a finite range of attenuation and noise.
引用
收藏
相关论文
共 50 条
  • [41] Phase Diffusion Mitigation in the Truncated Mach-Zehnder Interferometer
    Liao, Quan
    Ma, Hongmei
    Chen, Liqing
    Zhang, Weiping
    Yuan, Chun-Hua
    SYMMETRY-BASEL, 2024, 16 (02):
  • [42] Arbitrary phase-locking in Mach-Zehnder interferometer
    Wu, Shuhe
    Huang, Wenfeng
    Yang, Peiyu
    Liu, Shuqi
    Chen, Liqing
    OPTICS COMMUNICATIONS, 2019, 442 : 148 - 151
  • [43] RANDOM ERROR OF INTERFERENCE FRINGE MEASUREMENTS USING A MACH - ZEHNDER INTERFEROMETER
    HOWES, WL
    BUCHELE, DR
    APPLIED OPTICS, 1966, 5 (05): : 870 - &
  • [44] MACH-ZEHNDER INTERFEROMETER FOR DIFFUSION MEASUREMENTS IN VOLATILE LIQUID SYSTEMS
    CALDWELL, CS
    HALL, JR
    BABB, AL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1957, 28 (10): : 816 - 821
  • [45] Mach-Zehnder-Fano interferometer
    Miroshnichenko, Andrey E.
    Kivshar, Yuri S.
    APPLIED PHYSICS LETTERS, 2009, 95 (12)
  • [46] Mach-Zehnder interferometer and the teleporter
    Ralph, TC
    PHYSICAL REVIEW A, 2000, 61 (04): : 4 - 443014
  • [47] MACH-ZEHNDER HETERODYNE INTERFEROMETER
    LAVAN, MJ
    VANDAMME, GE
    CADWALLENDER, WK
    OPTICAL ENGINEERING, 1976, 15 (05) : 464 - 466
  • [48] ASTIGMATISM IN MACH-ZEHNDER INTERFEROMETER
    PROWSE, DB
    APPLIED OPTICS, 1967, 6 (04): : 773 - &
  • [49] ASTIGMATISM IN MACH-ZEHNDER INTERFEROMETER
    TANNER, LH
    HOWES, WL
    BUCHELE, DR
    PROWSE, DB
    APPLIED OPTICS, 1967, 6 (09): : 1583 - &
  • [50] A double image Mach–Zehnder interferometer
    W. A. Ramadan
    A. S. El-Tawargy
    Applied Physics B, 2015, 118 : 203 - 208