A double image Mach–Zehnder interferometer

被引:0
|
作者
W. A. Ramadan
A. S. El-Tawargy
机构
[1] Damietta University,Department of Physics, Faculty of Science
来源
Applied Physics B | 2015年 / 118卷
关键词
Beam Splitter; Polarize Beam Splitter; Polypropylene Fibre; Refractive Index Profile; Zehnder Interferometer;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, we present a modified version of the Mach–Zehnder interferometer. An arrangement of two linear polarizers and a wave rotator has been inserted in the light’s path. Using this new arrangement, we are able to obtain a double image of a birefringent fibre. This double image records the shifts of the Mach–Zehnder’s fringes for the light vibrating parallel and perpendicular to the fibre’s axis in the same image. Moreover, by controlling the beam splitters, we are able to get an overlap between two images of the fibre and to directly observe an image describing the birefringence of the investigated fibre. This new arrangement has been applied to three polypropylene fibres and a graded-index FOS optical fibre in order to demonstrate its validity and powerful ability for monitoring the direct birefringence. A set of images of the investigated samples is presented and compared with images obtained using the classical Mach–Zehnder interferometer.
引用
收藏
页码:203 / 208
页数:5
相关论文
共 50 条
  • [1] A double image Mach-Zehnder interferometer
    Ramadan, W. A.
    El-Tawargy, A. S.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2015, 118 (02): : 203 - 208
  • [2] DOUBLE MACH-ZEHNDER HETERODYNE INTENSITY INTERFEROMETER
    SOEMARJONO, A
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1975, 14 (06) : 841 - 848
  • [3] Optical image hiding with a modified Mach-Zehnder interferometer
    Li, Jun
    Li, Jiaosheng
    Pan, Yangyang
    Li, Rong
    OPTICS AND LASERS IN ENGINEERING, 2014, 55 : 258 - 261
  • [4] An electronic Mach–Zehnder interferometer
    Yang Ji
    Yunchul Chung
    D. Sprinzak
    M. Heiblum
    D. Mahalu
    Hadas Shtrikman
    Nature, 2003, 422 (6930) : 415 - 418
  • [5] AN INEXPENSIVE MACH ZEHNDER INTERFEROMETER
    WEIMER, D
    BLEAKNEY, W
    WHITE, DR
    PHYSICAL REVIEW, 1953, 91 (04): : 1032 - 1032
  • [6] Mach-Zehnder-Fano interferometer
    Miroshnichenko, Andrey E.
    Kivshar, Yuri S.
    APPLIED PHYSICS LETTERS, 2009, 95 (12)
  • [7] Mach-Zehnder interferometer and the teleporter
    Ralph, TC
    PHYSICAL REVIEW A, 2000, 61 (04): : 4 - 443014
  • [8] MACH-ZEHNDER HETERODYNE INTERFEROMETER
    LAVAN, MJ
    VANDAMME, GE
    CADWALLENDER, WK
    OPTICAL ENGINEERING, 1976, 15 (05) : 464 - 466
  • [9] ASTIGMATISM IN MACH-ZEHNDER INTERFEROMETER
    PROWSE, DB
    APPLIED OPTICS, 1967, 6 (04): : 773 - &
  • [10] ASTIGMATISM IN MACH-ZEHNDER INTERFEROMETER
    TANNER, LH
    HOWES, WL
    BUCHELE, DR
    PROWSE, DB
    APPLIED OPTICS, 1967, 6 (09): : 1583 - &