NEMA NU 2–2007 performance characteristics of GE Signa integrated PET/MR for different PET isotopes

被引:0
|
作者
Paulo R. R. V. Caribé
M. Koole
Yves D’Asseler
Timothy W. Deller
K. Van Laere
S. Vandenberghe
机构
[1] Ghent University,Medical Imaging and Signal Processing – MEDISIP
[2] UZ/KU Leuven,Division of Nuclear Medicine and Molecular Imaging
[3] GE Healthcare,undefined
来源
关键词
PET/MR; NEMA NU 2–2007; F; Ga; Y;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [11] Implementation of Image Reconstruction for GE SIGNA PET/MR PET Data in the STIR Library
    Wadhwa, Palak
    Thielemans, Kris
    Efthimiou, Nikos
    Bertolli, Ottavia
    Emond, Elise
    Thomas, Benjamin A.
    Tohme, Michel
    Wangerin, Kristen A.
    Delso, Gaspar
    Hallett, William
    Gunn, Roger N.
    Buckley, David
    Tsoumpas, Charalampos
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [12] Optimization of the spatial resolution for the GE discovery PET/CT 710 by using NEMA NU 2-2007 standards
    Hyun Jin Yoon
    Young Jin Jeong
    Hye Joo Son
    Do-Young Kang
    Kyung-Yae Hyun
    Min-Kyung Lee
    Journal of the Korean Physical Society, 2015, 66 : 287 - 294
  • [13] Optimization of the Spatial Resolution for the GE Discovery PET/CT 710 by Using NEMA NU 2-2007 Standards
    Yoon, Hyun Jin
    Jeong, Young Jin
    Son, Hye Joo
    Kang, Do-Young
    Hyun, Kyung-Yae
    Lee, Min-Kyung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (02) : 287 - 294
  • [14] NEMA 2007 performance characteristics of the Siemens mCT PET/CT camera
    de Jong, J. R.
    Schoenahl, F.
    Wierts, R.
    Lazarenko, S.
    Segbers, M.
    Dierckx, R. A. J. O.
    Paans, A. M. J.
    Willemsen, A. T. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S333 - S333
  • [15] Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests
    Demir, Mustafa
    Toklu, Turkay
    Abuqbeitah, Mohammad
    Cetin, Huseyin
    Sezgin, H. Sezer
    Yeyin, Nami
    Sonmezoglu, Kerim
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2018, 27 (01) : 10 - 18
  • [16] NEMA NU 2-2007 performance measurements of the Siemens Inveon™ preclinical small animal PET system
    Kemp, Brad J.
    Hruska, Carrie B.
    McFarland, Aaron R.
    Lenox, Mark W.
    Lowe, Val J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08): : 2359 - 2376
  • [17] Performance measurements for the PET/CT Discovery-600 using NEMA NU 2-2007 standards
    De Ponti, E.
    Morzenti, S.
    Guerra, L.
    Pasquali, C.
    Arosio, M.
    Bettinardi, V.
    Crespi, A.
    Gilardi, M. C.
    Messa, C.
    MEDICAL PHYSICS, 2011, 38 (02) : 968 - 974
  • [18] Performance tests for ray-scan 64 PET/CT based on NEMA NU-2 2007
    Li, Suying
    Zhou, Kun
    Zhang, Qiushi
    Zhang, Jinming
    Yang, Kun
    Xu, Baixuan
    Ren, Qiushi
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [19] PET performance measurements using the NEMA NU 2-2001 standard
    Daube-Witherspoon, ME
    Karp, JS
    Casey, ME
    DiFilippo, FP
    Hines, H
    Muehllehner, G
    Simcic, V
    Stearns, CW
    Adam, LE
    Kohlmyer, S
    Sossi, V
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (10) : 1398 - 1409
  • [20] Technical Note: Adapting a GE SIGNA PET/MR scanner for radiotherapy
    Brynolfsson, Patrik
    Axelsson, Jan
    Holmberg, August
    Jonsson, Joakim H.
    Goldhaber, David
    Jian, Yiqiang
    Illerstam, Fredrik
    Engstrom, Mathias
    Zackrisson, Bjorn
    Nyholm, Tufve
    MEDICAL PHYSICS, 2018, 45 (08) : 3546 - 3550