NEMA NU 2–2007 performance characteristics of GE Signa integrated PET/MR for different PET isotopes

被引:0
|
作者
Paulo R. R. V. Caribé
M. Koole
Yves D’Asseler
Timothy W. Deller
K. Van Laere
S. Vandenberghe
机构
[1] Ghent University,Medical Imaging and Signal Processing – MEDISIP
[2] UZ/KU Leuven,Division of Nuclear Medicine and Molecular Imaging
[3] GE Healthcare,undefined
来源
关键词
PET/MR; NEMA NU 2–2007; F; Ga; Y;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Performance evaluation of quantitative SPECT/CT using NEMA NU 2 PET methodology
    Ryu, HyunJu
    Meikle, Steven R.
    Willowson, Kathy P.
    Eslick, Enid M.
    Bailey, Dale L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14):
  • [22] Performance Characteristics of a New GE Research PET/CT Scanner Using the NEMA Standard
    Mawlawi, O.
    Pan, T.
    Bradley, M. W.
    Macapinlac, H. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S51 - S51
  • [23] Performance Evaluation of a PET of 7T Bruker Micro-PET/MR Based on NEMA NU 4-2008 Standards
    Doss, Kishore Krishnagiri Manoj
    Mion, Pei En
    Kao, Yu-Chieh Jill
    Kuo, Tsung-Ter
    Chen, Jyh-Cheng
    ELECTRONICS, 2022, 11 (14)
  • [24] Performance characteristics of a new development dedicated breast PET scanner evaluated with the NEMA NU 2-2008 standard
    Inoue, Mika
    Nakamoto, Yuji
    Matsumoto, Keiichi
    Kawase, Shigeto
    Yamakawa, Yoshiyuki
    Ohi, Junichi
    Kitamura, Keishi
    Togashi, Kaori
    Higashimura, Kyoji
    Onoguchi, Masahisa
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [25] Performance Characteristics of the MAMMI PEMT Scanner Based on NEMA NU 2-2007
    Moliner, L.
    Benlloch, J. M.
    Carles, M.
    Correcher, C.
    Gonzalez, A. J.
    Orero, A.
    Sanchez, F.
    Soriano, A.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2591 - 2594
  • [26] NEMA Performance Characteristics of the UHR Brain PET Scanner
    Lecomte, Roger
    Auger, Etienne
    Loignon-Houle, Francis
    Toussaint, Maxime
    Doyon, Vincent
    Thibaudeau, Christian
    Beaudoin, Jean-Francois
    Croteau, Etienne
    Leroux, Jean-Daniel
    Gaudreault, Maxime
    Samson, Arnaud
    Arpin, Louis
    Bouchard, Jonathan
    Espagnet, Romain
    Collin, Louis-Michel
    Hachey, Marc-Andre
    Dufour-Forget, Danae
    Koua, Konin
    Lemay, Joel
    Viscogliosi, Nicolas
    Pepin, Catherine
    Labrecque, Vincent
    Paulin, Caroline
    Marin, Thibault
    Normandin, Marc
    Tetrault, Marc-Andre
    Michaud, Jean-Baptiste
    El Fakhri, Georges
    Fontaine, Rejean
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [27] NEMA NU2-2012 performance evaluation of the Philips Vereos PET/CT System
    Rausch, I.
    Ruiz, A.
    Valverde-Pascual, I.
    Cal-Gonzalez, J.
    Beyer, T.
    Carrio, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S715 - S715
  • [28] Performance characteristics of the GE Discovery ST PET/CT scanner using the NEMA standard.
    Mawlawi, O
    Kohlmyer, S
    Williams, JJ
    Stearns, CW
    Culp, RF
    Podoloff, DA
    Macapinlac, H
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 111P - 111P
  • [29] Validation of ZTE head attenuation correction in the GE SIGNA PET/MR initial results
    Schramm, Georg
    Rezaei, Ahmadreza
    Willekens, Stefanie
    Van Weehaeghe, Donatienne
    Mertens, Nathalie
    Koole, Michel
    Nuyts, Johan
    Van Laere, Koen
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [30] Design Features and Mutual Compatibility Studies of the Time-of-Flight PET Capable GE SIGNA PET/MR System
    Levin, Craig S.
    Maramraju, Harsha
    Khalighi, Mohammad Mehdi
    Deller, Timothy W.
    Delso, Gaspar
    Jansen, Floris
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (08) : 1907 - 1914