Evaluation of the new LCx HIV RNA quantitative assay: comparison with the Cobas Amplicor HIV Monitor assay

被引:0
|
作者
Annemarie Berger
Holger F. Rabenau
Aribert Stief
Hugo Troonen
Hans W. Doerr
机构
[1] Institute for Medical Virology,
[2] Johann Wolfgang Goethe University Hospital,undefined
[3] Paul Ehrlich-Str. 40,undefined
[4] 60596 Frankfurt am Main,undefined
[5] Germany,undefined
[6] Abbott Diagnostika,undefined
[7] Wiesbaden Delkenheim,undefined
[8] Germany,undefined
来源
关键词
Quantitative Viral load HIV subtype LCx;
D O I
暂无
中图分类号
学科分类号
摘要
In the present study we evaluated the performance of the new LCx HIV RNA quantitative kit (Abbott Laboratories, Delkenheim, Germany) for the quantitative detection of HIV-1 RNA in human plasma in comparison to the Cobas Amplicor HIV-1 Monitor assay (Roche Diagnostics, Branchburg, N.J.), including samples containing a variety of HIV-1 subtypes. LCx and Cobas were compared using archived EDTA plasma samples collected from HIV-infected patients. Considering the lower limit of the linear range of 50 copies/ml, the detection rate of the LCx was 139 out of 174 (79.9%) versus 131 out of 174 (75.3%) of the Cobas. Overall agreement was 95.4% (166/174) at a cut-off of 50 copies. LCx and Cobas results on clinical samples were found linearly associated (r2=0.900) and strongly correlated (r=0.949). The mean viral load in the 174 frozen patient samples was 3.25 log10 copies/ml by LCx compared to 2.71 log10 copies/ml by Cobas. Considering only samples with a viral load ≥50 copies/ml, the average difference was –0.132 log copy/ml. Using a panel consisting of 9 plasma samples spiked with 9 different HIV-1 cultured isolates (A-H, and O) LCx detected the 9 subtypes with a high degree of precision, i.e., 9–33% coefficient of variation. As expected, the Cobas failed to detect the group O isolates. The results of the remaining samples showed a higher degree of variation (when testing four replicates of the subtype panel) than the LCx of 14.2–40.3%. Nevertheless, the results were comparable with the LCx data.
引用
收藏
页码:129 / 134
页数:5
相关论文
共 50 条
  • [21] Comparison of a duplex quantitative real-time PCR assay and the COBAS amplicor CMV monitor test for detection of cytomegalovirus
    Herrmann, B
    Larsson, VC
    Rubin, CJ
    Sund, F
    Eriksson, BM
    Arvidson, J
    Yun, ZB
    Bondeson, K
    Blomberg, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (05) : 1909 - 1914
  • [22] Evaluation of the Abbott RealTime CT/NG Assay in Comparison to the Roche Cobas Amplicor CT/NG Assay
    Cheng, Annie
    Qian, Qinfang
    Kirby, James E.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (04) : 1294 - 1300
  • [23] Evaluation of the COBAS Amplicor HBV Monitor assay and comparison with the Ultrasensitive HBV Hybrid Capture 2 assay for quantification of hepatitis B virus DNA
    Konnick, EQ
    Erali, M
    Ashwood, ER
    Hillyard, DR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (02) : 596 - 603
  • [24] Evaluation of clinical usefulness of second-generation HCV core antigen assay: comparison with COBAS AMPLICOR HCV MONITOR assay version 2.0
    Yokosuka, O
    Kawai, S
    Suzuki, Y
    Fukai, K
    Imazeki, F
    Kanda, T
    Tada, M
    Mikata, R
    Hata, A
    Saisho, H
    LIVER INTERNATIONAL, 2005, 25 (06) : 1136 - 1141
  • [25] Evaluation of the ultrasensitive Roche Amplicor HIV-1 monitor assay for quantitation of human immunodeficiency virus type I RNA
    Erali, M
    Hillyard, DR
    JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (03) : 792 - 795
  • [26] Improved Performance of COBAS AmpliPrep/COBAS TaqMan Version 2.0 Assay Over Amplicor Monitor Version 1.5 in the Quantification of HIV-1 RNA Viral Load in Abuja, Nigeria
    Abubakar, Ado
    Ndembi, Nicaise
    Ogbanufe, Obinna
    Inalegwu, Auchi
    Wilson, Simi
    Ebagua, Irene
    Peters, Sam
    Chime, Chris
    Dakum, Patrick
    Abimiku, Alash'le G.
    CURRENT HIV RESEARCH, 2015, 13 (04) : 262 - 267
  • [27] Quantification of HIV-1 group M (subtypes A-G) and group O by the LCx HIV RNA quantitative assay
    Swanson, P
    Harris, BJ
    Holzmayer, V
    Devare, SG
    Schochetman, G
    Hackett, J
    JOURNAL OF VIROLOGICAL METHODS, 2000, 89 (1-2) : 97 - 108
  • [28] Comparison of the Roche COBAS Amplicor™ monitor, Roche COBAS Ampliprep™/COBAS Taqman™ and Abbott RealTime™ test assays for quantification of hepatitis c virus and HIV RNA
    Wolff, Dietmar
    Gerritzen, Andreas
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (07) : 917 - 922
  • [29] EVALUATION OF ROCHE AMPLICOR HCV MONITOR ASSAY
    FARUKI, H
    KOPKO, S
    HEPATOLOGY, 1995, 22 (04) : 1235 - 1235
  • [30] Multi-center evaluation of the LCX HCV RNA quantitative assay
    Pawlotsky, JM
    Jilg, W
    Zanetti, AR
    Bouvier-Alias, M
    Hottenträger, B
    Romanò, L
    Lennartz, L
    Ofsaiof, R
    Campbell, D
    Leckie, G
    JOURNAL OF HEPATOLOGY, 2001, 34 : 128 - 128