Evaluation of the new LCx HIV RNA quantitative assay: comparison with the Cobas Amplicor HIV Monitor assay

被引:0
|
作者
Annemarie Berger
Holger F. Rabenau
Aribert Stief
Hugo Troonen
Hans W. Doerr
机构
[1] Institute for Medical Virology,
[2] Johann Wolfgang Goethe University Hospital,undefined
[3] Paul Ehrlich-Str. 40,undefined
[4] 60596 Frankfurt am Main,undefined
[5] Germany,undefined
[6] Abbott Diagnostika,undefined
[7] Wiesbaden Delkenheim,undefined
[8] Germany,undefined
来源
关键词
Quantitative Viral load HIV subtype LCx;
D O I
暂无
中图分类号
学科分类号
摘要
In the present study we evaluated the performance of the new LCx HIV RNA quantitative kit (Abbott Laboratories, Delkenheim, Germany) for the quantitative detection of HIV-1 RNA in human plasma in comparison to the Cobas Amplicor HIV-1 Monitor assay (Roche Diagnostics, Branchburg, N.J.), including samples containing a variety of HIV-1 subtypes. LCx and Cobas were compared using archived EDTA plasma samples collected from HIV-infected patients. Considering the lower limit of the linear range of 50 copies/ml, the detection rate of the LCx was 139 out of 174 (79.9%) versus 131 out of 174 (75.3%) of the Cobas. Overall agreement was 95.4% (166/174) at a cut-off of 50 copies. LCx and Cobas results on clinical samples were found linearly associated (r2=0.900) and strongly correlated (r=0.949). The mean viral load in the 174 frozen patient samples was 3.25 log10 copies/ml by LCx compared to 2.71 log10 copies/ml by Cobas. Considering only samples with a viral load ≥50 copies/ml, the average difference was –0.132 log copy/ml. Using a panel consisting of 9 plasma samples spiked with 9 different HIV-1 cultured isolates (A-H, and O) LCx detected the 9 subtypes with a high degree of precision, i.e., 9–33% coefficient of variation. As expected, the Cobas failed to detect the group O isolates. The results of the remaining samples showed a higher degree of variation (when testing four replicates of the subtype panel) than the LCx of 14.2–40.3%. Nevertheless, the results were comparable with the LCx data.
引用
收藏
页码:129 / 134
页数:5
相关论文
共 50 条
  • [41] Differences between the quantitative antigenemia assay and the COBAS Amplicor Monitor quantitative PCR assay for detecting CMV viraemia in bone marrow and solid organ transplant patients
    Flexman, J
    Kay, I
    Fonte, R
    Herrmann, R
    Gabbay, E
    Palladino, S
    JOURNAL OF MEDICAL VIROLOGY, 2001, 64 (03) : 275 - 282
  • [42] Performance of the new Bayer VERSANT™ HCV 3.0 RNA assay (bDNA) for quantitation of HCV RNA in plasma and serum:: Conversion to international units and comparison with the Roche COBAS AMPLICOR HCV Monitor 2.0 assay.
    Beld, M
    Sentjens, R
    Rebers, S
    Weegink, CJ
    Weel, J
    Sol, C
    Boom, R
    HEPATOLOGY, 2001, 34 (04) : 223A - 223A
  • [43] Single sample prep for two assays -: Abbott LCx® HIV-1 RNA quantitative (LCx) assay and celera diagnostics ViroSeq™ HIV-1 genotyping system.
    Marlowe, N
    Swanson, P
    Drews, B
    Hackett, J
    CLINICAL CHEMISTRY, 2002, 48 (11) : 2090 - 2090
  • [44] Dynamic range of hepatitis C virus RNA quantification with the cobas ampliprep-cobas amplicor HCV monitor v2.0 assay
    Gourlain, K
    Soulier, A
    Pellegrin, B
    Bouvier-Alias, M
    Hézode, C
    Darthuy, F
    Rémiré, J
    Pawlotsky, JM
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (04) : 1669 - 1673
  • [45] Development of a quantitative assay for HIV-1 RNA
    MacLean, PM
    Levasseur, PJ
    Weinbaum, B
    McCarty, JM
    Burg, JL
    AIDS, 2000, 14 : S108 - S108
  • [46] Performance of the new Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: Conversion to international units and comparison with the Roche COBAS amplicor HCV monitor, version 2.0, assay
    Beld, M
    Sentjens, R
    Rebers, S
    Weegink, C
    Weel, J
    Sol, C
    Boom, R
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (03) : 788 - 793
  • [47] Rapid quantification of HIV using the Cepheid HIV-1 Viral Load Assay: A comparison with COBAS AmpliPrep/COBAS TaqMan HIV Test®
    Rahamat-Langendoen, J.
    Kuijpers, J.
    Melchers, W. J. G.
    JOURNAL OF CLINICAL VIROLOGY, 2015, 70 : S99 - S99
  • [48] Effect of errors in the sequence of optical densities from the Roche AMPLICOR HIV-1 MONITOR assay on the validity of assay results
    Brambilla, DJ
    Granger, S
    Jennings, C
    Bremer, JW
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (03) : 1118 - 1120
  • [49] Evaluation of the Abbott LCx quantitative assay for measurement of human immunodeficiency virus RNA in plasma
    de Mendoza, C
    Alcamí, J
    Sainz, M
    Folgueira, D
    Soriano, V
    JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (04) : 1518 - 1521
  • [50] Dynamic range of HCV RNA quantification of the Cobas AmpliPrep-Cobas Amplicor HCV Monitor V2.0 assay, a widely used PCR-based HCV RNA quantification assay.
    Gourlain, K
    Soulier, A
    Bouvier-Alias, M
    Hezode, C
    Darthuy, F
    Remire, J
    Pawlotsky, JM
    HEPATOLOGY, 2004, 40 (04) : 682A - 682A