Comparison of a duplex quantitative real-time PCR assay and the COBAS amplicor CMV monitor test for detection of cytomegalovirus

被引:33
|
作者
Herrmann, B
Larsson, VC
Rubin, CJ
Sund, F
Eriksson, BM
Arvidson, J
Yun, ZB
Bondeson, K
Blomberg, J
机构
[1] Uppsala Univ, Dept Med Sci, Sect Virol, Uppsala, Sweden
[2] Uppsala Univ, Dept Med Sci, Infect Dis Sect, Uppsala, Sweden
[3] Uppsala Univ, Dept Womens & Childrens Hlth, Sect Pediat, Uppsala, Sweden
[4] Huddinge Univ Hosp, Dept Clin Virol, Stockholm, Sweden
关键词
D O I
10.1128/JCM.42.5.1909-1914.2004
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A duplex quantitative real-time PCR (qPCR) assay was designed to detect both the polymerase gene (pol) and the glycoprotein gene (gB) of cytomegalovirus (CMV). The detection limit of the qPCR was determined to be 1 to 3 copies/reaction and the linear measure interval was 10(3) to 10(8) copies/ml. The qPCR system was compared to the COBAS Amplicor CMV Monitor test (COBAS) by an analysis of 138 plasma samples. Both systems detected CMV in 71 cases and had negative results for 33 samples. In addition, 34 samples were positive by qPCR and negative by the COBAS assay, but in no case was the COBAS result positive and the qPCR result negative. Thus, qPCR detected 48% more positive cases than the COBAS method. For samples with greater than or equal to10(5) copies/ml by qPCR, a saturation effect was seen in the COBAS assay and quantification required dilution. Copy numbers for pol and gB by qPCR generally agreed. However, the reproducibility of qPCR assays and the need for an international standard are discussed. Discrepant copy numbers for pol and gB by qPCR were found for samples from two patients, and sequence analysis revealed that the corresponding CMV strains were mismatched at four nucleotide positions compared with the gB fragment primer sequences. In conclusion, a duplex qPCR assay in a real-time format facilitates quantitative measurements and minimizes the risk of false-negative results.
引用
收藏
页码:1909 / 1914
页数:6
相关论文
共 50 条
  • [1] Evaluation of the AMPLICOR CMV, COBAS AMPLICOR CMV monitor and antigenemia assay for cytomegalovirus disease
    Masaoka, T
    Hiraoka, A
    Ohta, K
    Tatsumi, N
    Watanabe, S
    Hotta, T
    Yabe, H
    Kato, S
    Aikawa, A
    Ohara, T
    Hasegawa, A
    Tanabe, K
    Toma, H
    Yasuoka, A
    Oka, S
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2001, 54 (01) : 12 - 16
  • [2] Comparison of quantitative cytomegalovirus (CMV) PCR in plasma and CMV antigenemia assay: Clinical utility of the prototype AMPLICOR CMV MONITOR test in transplant recipients
    Caliendo, AM
    St George, K
    Kao, SY
    Allega, J
    Tan, BH
    LaFontaine, R
    Bui, L
    Rinaldo, CR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (06) : 2122 - 2127
  • [3] Evaluation of the ReSSQ assay in relation to the COBAS AMPLICOR CMV MONITOR test and an in-house nested PCR method for detection of cytomegalovirus DNA
    Wirgart, BZ
    Andersson, P
    Grillner, L
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (08) : 4057 - 4063
  • [4] Comparison of two different real-time PCR assays and the COBAS Amplicor CMV monitor for the detection of cytomegalovirus DNA in patients following allogeneic stem cell transplantation.
    Hebart, H
    Loeffler, J
    Szentgyoergyi, E
    Einsele, H
    BLOOD, 2001, 98 (11) : 357B - 357B
  • [5] Quantitative analysis of cytomegalovirus (CMV) viremia using the pp65 antigenemia assay and the COBAS AMPLICOR CMV MONITOR PCR test after blood and marrow allogeneic transplantation
    Boivin, G
    Bélanger, R
    Delage, R
    Béliveau, C
    Demers, C
    Goyette, N
    Roy, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (12) : 4356 - 4360
  • [6] Verification of the Roche Real-Time PCR COBAS AmpliPrep/COBAS TaqMan 48 HCV Test With the Roche COBAS AMPLICOR HCV Monitor, Version 2.0 Assay
    Varma, Tanya
    McRae, Kenneth L.
    Fogle, Edward
    Rinaudo, Stephanie
    Matthews-Greer, Janice
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2010, 134 (04) : 689 - 689
  • [7] Comparison of Droplet Digital PCR to Real-Time PCR for Quantitative Detection of Cytomegalovirus
    Hayden, R. T.
    Gu, Z.
    Ingersoll, J.
    Abdul-Ali, D.
    Shi, L.
    Pounds, S.
    Caliendo, A. M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (02) : 540 - 546
  • [8] Differences between the quantitative antigenemia assay and the COBAS Amplicor Monitor quantitative PCR assay for detecting CMV viraemia in bone marrow and solid organ transplant patients
    Flexman, J
    Kay, I
    Fonte, R
    Herrmann, R
    Gabbay, E
    Palladino, S
    JOURNAL OF MEDICAL VIROLOGY, 2001, 64 (03) : 275 - 282
  • [9] A duplex real-time PCR assay for the quantitative detection of Naegleria fowleri in water samples
    Behets, Jonas
    Declerck, Priscilla
    Delaedt, Yasmine
    Verelst, Lieve
    Ollevier, Frans
    WATER RESEARCH, 2007, 41 (01) : 118 - 126
  • [10] A duplex quantitative real-time PCR assay for the detection of Haplosporidium and Perkinsus species in shellfish
    Zhixun Xie
    Liji Xie
    Qing Fan
    Yaoshan Pang
    Xianwen Deng
    Zhi Qin Xie
    Jiabo Liu
    Mazhar I. Khan
    Parasitology Research, 2013, 112 : 1597 - 1606