To prospectively compare the left ventricular end-diastolic volume (LVEDV), end-systolic volume (LVESV), and ejection fraction (LVEF) obtained from gated perfusion single photon emission computed tomography (GSPECT) with those obtained from cardiac magnetic resonance imaging (MRI) in patients with idiopathic dilated cardiomyopathy (IDC). Twenty-one patients with IDC (6 females) with a median age of 45 years (range 17–65) were scheduled for 99mTc-tetrofosmin-GSPECT and MRI within a 3 h interval. In both methods LV volumes were analyzed with the Simpson method. Both GSPECT and MRI were successfully completed in 90% of patients. Close linear correlations were observed between the two methods in LVEDV (R = 0.918; P < 0.001) and LVESV (R = 0.946; P < 0.001), but correlations were significantly weaker in LVEF (R = 0.323; P = 0.082). LVEDV and LVESV were smaller in GSPECT than in MRI (161 ± 73 vs. 214 ± 87 ml, P < 0.001, and 116 ± 64 vs. 138 ± 72 ml, P < 0.001, respectively). In 4 patients (21%) the LVEDV index was considered normal by GSPECT and increased by MRI, if MRI-derived normal values were used. No difference was found between GSPECT and MRI when LVEFMRI was ≤40%, but GSPECT showed smaller LVEF when LVEFMRI was over 40% (33 ± 11 vs. 50 ± 5%; P < 0.05). The finding of increased LVEDV in GSPECT is reliable compared with MRI. However, LV volumes were underestimated by GSPECT and no direct comparisons can be made between methods in follow up studies. Abnormal results should be confirmed by another imaging modality, such as MRI, if these findings have therapeutic consequences.
引用
收藏
页码:629 / 634
页数:5
相关论文
共 50 条
  • [31] Reliability of left ventricular ejection fraction calculated with gated myocardial perfusion single photon emission computed tomography in patients with extensive perfusion defect
    Harisankar, Chidambaram Natrajan Balasubramanian
    Mittal, Bhagwant Rai
    Kamaleshwaran, Koramadai Karuppuswamy
    Parmar, Madan
    Bhattacharya, Anish
    Singh, Baljinder
    Mahajan, Rajiv
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (06) : 503 - 507
  • [32] Comparison of multislice computed tomography to gated single-photon emission computed tomography for imaging of healed myocardial infarcts
    Henneman, Maureen M.
    Schuijf, Joanne D.
    Dibbets-Schneider, Petra
    Stokkel, Marcel P.
    van der Geest, Rob J.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (02): : 144 - 148
  • [33] Multislice gated cardiac computed tomography accurately estimates left ventricular volumes and ejection fraction
    Belge, B
    Vlassenbroeck, A
    Coche, E
    Vembar, M
    Ciancibello, L
    Johnson, PC
    Vanbeers, B
    Vanoverschelde, JLJ
    Gerber, BL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 330A - 330A
  • [34] Comparison of cardiac computed tomography to magnetic resonance imaging: left ventricular volumes and function
    Groothuis, J. G. J.
    Fransen, M.
    Beek, A. M.
    Brinckman, S. L.
    Meijerink, M. R.
    Hofman, M. B. M.
    Van Kuijk, C.
    Van Rossum, A. C.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A77 - A77
  • [35] Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods
    Tracy L. Faber
    Johnathan P. Vansant
    Roderic I. Pettigrew
    James R. Galt
    Michel Blais
    George Chatzimavroudis
    C. David Cooke
    Russell D. Folks
    Sandra M. Waldrop
    Elzbieta Gurtler-Krawczynska
    Mark D. Wittry
    Ernest V. Garcia
    Journal of Nuclear Cardiology, 2001, 8 : 645 - 651
  • [36] Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: Comparison of two methods
    Faber, TL
    Vansant, JP
    Pettigrew, RI
    Galt, JR
    Blais, M
    Chatzimavroudis, G
    Cooke, CD
    Folks, RD
    Waldrop, SM
    Gurtler-Krawczynska, E
    Wittry, MD
    Garcia, EV
    JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (06) : 645 - 651
  • [37] Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging and the Risk of Sudden Cardiac Death in Patients With Coronary Disease and Left Ventricular Ejection Fraction &gt;35%
    Piccini, Jonathan P.
    Starr, Aijing Z.
    Horton, John R.
    Shaw, Linda K.
    Lee, Kerry L.
    Al-Khatib, Sana M.
    Iskandrian, Ami E.
    O'Connor, Christopher M.
    Borges-Neto, Salvador
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (03) : 206 - 214
  • [38] Comparison of the prognostic value of baseline and nitrate single-photon emission computed tomography Imaging in patients with ischemic left ventricular dysfunction
    Evangelista, L.
    Acampa, W.
    Sorrentino, A. R.
    Luongo, L.
    Petretta, M.
    Salvatore, M.
    Cuocolo, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S181 - S182
  • [39] Correlation of myocardial perfusion, as assessed by positron emission tomography, and left ventricular ejection fraction and exercise tolerance in patients with idiopathic dilated cardiomyopathy
    vandenHeuvel, A
    vanVeldhuisen, DJ
    Blanksma, PK
    Anthonio, RL
    Siebelink, HMJ
    Staudt, JM
    Vaalburg, W
    CIRCULATION, 1997, 96 (08) : 375 - 375
  • [40] Left Ventricular Functional Analysis With 16-and 64-Row Multidetector Computed Tomography: Comparison With Gated Single-Photon Emission Computed Tomography
    Agarwal, Prachi P.
    Patel, Smita
    Corbett, James
    Jung, Jung Im
    Barber, Karen
    Schipper, Matthew
    Kazerooni, Ella A.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (01) : 8 - 14