Water target based cross-calibration of CBERS-02 CCD camera with MODIS data

被引:2
|
作者
Junwu Tang
Xingfa Gu
Shengli Niu
Chaofei Ma
Xiangjun Min
机构
[1] National Satellite Ocean Application Service (NSOAS),
[2] State Key Laboratory of Remote Sensing Science,undefined
[3] China Center for Resource Satellite Data and Applications (CRESDA),undefined
来源
关键词
CBERS-02 CCD; MODIS; radiometric calibration; cross-calibration;
D O I
10.1007/BF03039425
中图分类号
学科分类号
摘要
In order to make quantitative watercolor sensing with China-Brazil Earth Resources Satellite (CBERS-02) CCD camera, the MODIS data with higher accuracy is used to cross-calibrate the CCD camera over water targets. In homogeneous clear water area, two pairs of images obtained over the same area on the same day by the two sensors are selected. The top-of-atmosphere (TOA) radiances of the multispectral bands of CCD are calculated with the water and aerosol parameters from MODIS based on a water-atmosphere radiative transfer algorithm. The stripes in CCD image that caused by unequal response of the CCD array detectors are firstly removed before making the cross-calibration. The same part of CCD detectors is selected for the calibrations in the two images to eliminate the residual error of destriping and uniformity correction for the focus plane irradiance. It is shown that the calibration results from two different images are consistent. The error of this method is about 5%.
引用
收藏
页码:61 / 71
页数:10
相关论文
共 44 条
  • [21] Estimating surface evapotranspiration using combined MODIS and CBERS-02 data
    XIN Xiaozhou1
    2. Research Center for Remote Sensing and GIS
    3. Graduate University of Chinese Academy of Sciences
    4. Department of Atmospheric Physics
    Science China Technological Sciences, 2005, (S2) : 145 - 160
  • [22] Comparison of the influence factors on NDVI for CCD camera and WFI imager on CBERS-02
    Yu, T
    Li, XY
    Zhang, Y
    Zhao, F
    Gu, XF
    Zhu, L
    Wang, PX
    Min, XJ
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 : 100 - 115
  • [23] Estimating surface evapotranspiration using combined MODIS and CBERS-02 data
    Xin, XZ
    Liu, XH
    Tang, Y
    Tian, GL
    Gu, XF
    Li, XW
    Zheng, HS
    Chen, JY
    SCIENCE IN CHINA SERIES E-ENGINEERING & MATERIALS SCIENCE, 2005, 48 : 145 - 160
  • [24] Estimating surface evapotranspiration using combined MODIS and CBERS-02 data
    Xiaozhou Xin
    Qinhuo Liu
    Yong Tang
    Guoliang Tian
    Xingfa Gu
    Xiaowen Li
    Hongsheng Zheng
    Jiayi Chen
    Science in China Series E Engineering & Materials Science, 2005, 48 (Suppl 2): : 145 - 160
  • [25] 利用MODIS对CBERS-02卫星CCD相机进行辐射交叉定标
    李小英
    顾行发
    闵祥军
    余涛
    傅俏燕
    张勇
    李小文
    中国科学:技术科学, 2005, (S1) : 41 - 58
  • [26] 基于水体目标的CBERS-02卫星CCD相机与MODIS的交叉辐射定标
    唐军武
    顾行发
    牛生丽
    马超飞
    闵祥军
    中国科学:技术科学, 2005, (S1) : 59 - 69
  • [27] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    Zuo Wang
    PengFeng Xiao
    XingFa Gu
    XueZhi Feng
    XiaoYing Li
    HaiLiang Gao
    Hui Li
    JinTang Lin
    XueLiang Zhang
    Science China Technological Sciences, 2013, 56 : 713 - 723
  • [28] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    WANG Zuo
    XIAO PengFeng
    GU XingFa
    FENG XueZhi
    LI XiaoYing
    GAO HaiLiang
    LI Hui
    LIN JinTang
    ZHANG XueLiang
    Science China Technological Sciences, 2013, (03) : 713 - 723
  • [29] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    WANG Zuo
    XIAO PengFeng
    GU XingFa
    FENG XueZhi
    LI XiaoYing
    GAO HaiLiang
    LI Hui
    LIN JinTang
    ZHANG XueLiang
    Science China(Technological Sciences), 2013, 56 (03) : 713 - 723
  • [30] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    Wang Zuo
    Xiao PengFeng
    Gu XingFa
    Feng XueZhi
    Li XiaoYing
    Gao HaiLiang
    Li Hui
    Lin JinTang
    Zhang XueLiang
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2013, 56 (03) : 713 - 723