Water target based cross-calibration of CBERS-02 CCD camera with MODIS data

被引:2
|
作者
Junwu Tang
Xingfa Gu
Shengli Niu
Chaofei Ma
Xiangjun Min
机构
[1] National Satellite Ocean Application Service (NSOAS),
[2] State Key Laboratory of Remote Sensing Science,undefined
[3] China Center for Resource Satellite Data and Applications (CRESDA),undefined
来源
关键词
CBERS-02 CCD; MODIS; radiometric calibration; cross-calibration;
D O I
10.1007/BF03039425
中图分类号
学科分类号
摘要
In order to make quantitative watercolor sensing with China-Brazil Earth Resources Satellite (CBERS-02) CCD camera, the MODIS data with higher accuracy is used to cross-calibrate the CCD camera over water targets. In homogeneous clear water area, two pairs of images obtained over the same area on the same day by the two sensors are selected. The top-of-atmosphere (TOA) radiances of the multispectral bands of CCD are calculated with the water and aerosol parameters from MODIS based on a water-atmosphere radiative transfer algorithm. The stripes in CCD image that caused by unequal response of the CCD array detectors are firstly removed before making the cross-calibration. The same part of CCD detectors is selected for the calibrations in the two images to eliminate the residual error of destriping and uniformity correction for the focus plane irradiance. It is shown that the calibration results from two different images are consistent. The error of this method is about 5%.
引用
收藏
页码:61 / 71
页数:10
相关论文
共 44 条
  • [41] Radiometric cross-calibration of the Landsat-7 ETM+ and Landsat-5 TM sensors based on tandem data sets
    Teillet, PM
    Barker, JL
    Markham, BL
    Irish, RR
    Fedosejevs, G
    Storey, JC
    REMOTE SENSING OF ENVIRONMENT, 2001, 78 (1-2) : 39 - 54
  • [42] On-Orbit Geometric Calibration of the Panchromatic/Multispectral Camera of the ZY-1 02C Satellite based on Public Geographic Data
    Tao, Pengjie
    Lu, Luping
    Zhang, Yong
    Xu, Biao
    Zou, Songbai
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2014, 80 (06): : 505 - 517
  • [43] Probability-Based LIDAR-Camera Calibration Considering Target Positions and Parameter Evaluation Using a Data Fusion Map
    Yamada, Ryuhei
    Yaguchi, Yuichi
    SENSORS, 2024, 24 (12)
  • [44] Cross-camera comparison of ROI-based semi-quantitative 123I-IBZM SPECT data in healthy volunteers using an anthropomorphic phantom for calibration
    Mo, Susanna Jakobson
    Larsson, Anne
    Johansson, Lennart
    Stenlund, Hans
    Forsgren, Lars
    Riklund, Katrine
    ACTA RADIOLOGICA, 2013, 54 (05) : 549 - 556