Uncertainty analysis of cross-calibration for HJ-1 CCD camera

被引:19
|
作者
Wang Zuo [1 ,2 ]
Xiao PengFeng [1 ,2 ]
Gu XingFa [3 ,4 ]
Feng XueZhi [1 ,2 ]
Li XiaoYing [3 ,4 ]
Gao HaiLiang [3 ,4 ]
Li Hui [2 ,5 ]
Lin JinTang [2 ,6 ]
Zhang XueLiang [1 ,2 ]
机构
[1] Nanjing Univ, Jiangsu Prov Key Lab Geog Informat Sci & Technol, Nanjing 210093, Jiangsu, Peoples R China
[2] Nanjing Univ, Dept Geog Informat Sci, Nanjing 210093, Jiangsu, Peoples R China
[3] Chinese Acad Sci, Inst Remote Sensing Applicat, State Key Lab Remote Sensing Sci, Beijing 100101, Peoples R China
[4] Beijing Normal Univ, Beijing 100101, Peoples R China
[5] Xiamen Univ Technol, Dept Spatial Informat Sci & Engn, Xiamen 361024, Peoples R China
[6] Minjiang Univ, Dept Geog Sci, Fuzhou 350108, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
cross-calibration; uncertainty analysis; CCD camera; HJ-1; VICARIOUS CALIBRATION; SENSORS; MODIS;
D O I
10.1007/s11431-012-5109-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Radiometric calibration of sensor is the basis of quantitative remote sensing, and uncertainty analysis is critical to ensure the accuracy of cross-calibration. Therefore, firstly, cross-calibration formulas were improved by redefining calibration coefficient and spectral band matching factor. In these formulas, c (ci) was redefined as the calibration coefficient of normalized apparent reflectance, and spectral band matching factor as the ratio of normalized apparent reflectance. Secondly, based on the contrast of ideal and actual conditions in cross-calibration, 8 sources of cross-calibration uncertainty were proposed: calibration uncertainty of standard sensor; pixel matching uncertainty; spectral band matching factor uncertainty caused by site altitude setting error, atmospheric parameters setting error, surface spectrum source, surface bidirectional reflectance characteristic, and error of atmospheric radiative transfer model; and uncertainty caused by other factors which were not considered. Finally, the contribution of each uncertainty was further analyzed and discussed for the HJ-1 CCD camera. The results provide many valuable references for evaluating the feasibility of alternative cross-calibration measurements.
引用
收藏
页码:713 / 723
页数:11
相关论文
共 50 条
  • [1] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    Zuo Wang
    PengFeng Xiao
    XingFa Gu
    XueZhi Feng
    XiaoYing Li
    HaiLiang Gao
    Hui Li
    JinTang Lin
    XueLiang Zhang
    Science China Technological Sciences, 2013, 56 : 713 - 723
  • [2] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    WANG Zuo
    XIAO PengFeng
    GU XingFa
    FENG XueZhi
    LI XiaoYing
    GAO HaiLiang
    LI Hui
    LIN JinTang
    ZHANG XueLiang
    Science China Technological Sciences, 2013, (03) : 713 - 723
  • [3] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    WANG Zuo
    XIAO PengFeng
    GU XingFa
    FENG XueZhi
    LI XiaoYing
    GAO HaiLiang
    LI Hui
    LIN JinTang
    ZHANG XueLiang
    Science China(Technological Sciences), 2013, 56 (03) : 713 - 723
  • [4] Cross-Calibration of HJ-1/CCD Over a Desert Site Using Landsat ETM plus Imagery and ASTER GDEM Product
    Zhong, Bo
    Zhang, Yuhuan
    Du, Tengteng
    Yang, Aixia
    Lv, Wenbo
    Liu, Qinhuo
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2014, 52 (11): : 7247 - 7263
  • [5] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Xiaoying Li
    Xingfa Gu
    Xiangjun Min
    Tao Yu
    Qiaoyan Fu
    Yong Zhang
    Xiaowen Li
    Science in China Series E Engineering & Materials Science, 2005, 48 (Suppl 2): : 44 - 60
  • [6] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    LI Xiaoying1
    2. Graduate University of Chinese Academy of Sciences
    3. The Center for National Spaceborne Demonstration
    4. Institut National de la Recherche Agronomique
    5. China Center for Resource Satellite Data and Application
    Science China Technological Sciences, 2005, (S2) : 44 - 60
  • [7] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Li, XY
    Gu, XF
    Min, XJ
    Yu, TA
    Fu, QY
    Zhang, Y
    Li, XW
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 : 44 - 60
  • [8] Uncertainty analysis in cross-calibration and optimization calculation of calibration coefficients
    Gao Shuai
    Li Yuan
    Bai Ting-zhu
    Zhang Yu-xiang
    Zheng Xiao-bing
    CHINESE OPTICS, 2020, 13 (03): : 568 - 576
  • [9] Online Cross-Calibration of Camera and LIDAR
    Blaga, Bianca-Cerasela-Zelia
    Nedevschi, Sergiu
    2017 13TH IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTER COMMUNICATION AND PROCESSING (ICCP), 2017, : 295 - 301
  • [10] TRUTHS CROSS-CALIBRATION UNCERTAINTY TOOL
    Gorrono, Javier
    Fox, Nigel
    Bialek, Agnieszka
    Green, Paul
    Scanlon, Tracy
    2015 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2015, : 2135 - 2138