Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS

被引:4
|
作者
Xiaoying Li
Xingfa Gu
Xiangjun Min
Tao Yu
Qiaoyan Fu
Yong Zhang
Xiaowen Li
机构
[1] Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University,State Key Laboratory of Remote Sensing Science
[2] Graduate University of Chinese Academy of Sciences,Institut National de la Recherche Agronomique
[3] The Center for National Spaceborne Demonstration,undefined
[4] Climat Sol Environnement,undefined
[5] China Center for Resource Satellite Data and Application,undefined
来源
关键词
CBERS-02; CCD camera; cross-calibration; the spectral band matching factors;
D O I
10.1007/BF03039424
中图分类号
学科分类号
摘要
For the application of the CCD camera, the most important payload on CBERS-02, the key is to provide long-term stable radiometric calibration coefficients. Although the vicarious calibration had been proved successful, it had its limitations such as test site requirement and unsuitable for historical data. Cross-calibration is one of the alternative methods, but it needs synchro surface spectrum to achieve spectral band matching factors. Our effort is to probe the influences on these factors. Simulations with a lot of surface spectrum showed that the factors changed with the viewing geometry, atmospheric condition and surface targets. However, simulating with the same viewing geometry and atmospheric condition, the spectral band matching factors of the same or similar surface targets, spectrum acquired from different dates and different places would like to be consistent to each other within 1%–5%. Thus, the synchro measurement data can be substituted by the same or similar target from other source. Based on this method, using the MODIS as the reference, the cross-calibration was performed for CCD camera. The research demonstrated that the traditional method with single calibration site was inappropriate for CCD camera, since the offsets for its four spectral bands were not zeros. With four calibration sites, these offsets were obtained. And the camera was detected to degrade with dates based on four times of cross-calibrations.
引用
收藏
页码:44 / 60
页数:16
相关论文
共 50 条
  • [1] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    LI Xiaoying1
    2. Graduate University of Chinese Academy of Sciences
    3. The Center for National Spaceborne Demonstration
    4. Institut National de la Recherche Agronomique
    5. China Center for Resource Satellite Data and Application
    [J]. Science China Technological Sciences, 2005, (S2) : 44 - 60
  • [2] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Li, XY
    Gu, XF
    Min, XJ
    Yu, TA
    Fu, QY
    Zhang, Y
    Li, XW
    [J]. SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 : 44 - 60
  • [3] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    Junwu Tang
    Xingfa Gu
    Shengli Niu
    Chaofei Ma
    Xiangjun Min
    [J]. Science in China Series E Engineering & Materials Science, 2005, 48 (Suppl 2): : 61 - 71
  • [4] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    TANG Junwu1
    2. State Key Laboratory of Remote Sensing Science
    3. China Center for Resource Satellite Data and Applications (CRESDA)
    [J]. Science China Technological Sciences, 2005, (S2) : 61 - 71
  • [5] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    Tang, JW
    Gu, XF
    Niu, SL
    Ma, CF
    Min, XJ
    [J]. SCIENCE IN CHINA SERIES E-ENGINEERING & MATERIALS SCIENCE, 2005, 48 : 61 - 71
  • [6] Radiometric cross-calibration of CBERS-02 IRMSS thermal channel
    Zhang Yong
    Gu Xing-Fa
    Yu Tao
    Zhang Yu-Xiang
    Qi Rui-Li
    Li Xiao-Wen
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2006, 25 (04) : 261 - 266
  • [7] Radiometric cross-calibration of Terra ASTER and MODIS
    Yuan, Karen
    Thome, Kurt
    McCorkel, Joel
    [J]. EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [8] The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels
    Gao, Caixia
    Jiang, Xiaoguang
    Li, Xianbin
    Li, Xiaohui
    [J]. INTERNATIONAL JOURNAL OF REMOTE SENSING, 2013, 34 (9-10) : 3688 - 3698
  • [9] Absolute radiometric calibration of CBERS-02 IRMSS thermal band
    ZHANG Yong1
    2. Graduate University of Chinese Academy of Sciences
    3. The Center for National Spaceborne Demonstration
    4. Institut National de la Recherche Agronomique
    5. National Satellite Meteorological Center
    6. State Environmental Protection Administration
    [J]. Science China Technological Sciences, 2005, (S2) : 72 - 90
  • [10] Absolute radiometric calibration of CBERS-02 IRMSS thermal band
    Zhang, Y
    Gu, XF
    Tao, Y
    Zhang, YX
    Chen, LF
    Li, XY
    Li, XW
    He, LM
    [J]. SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 : 72 - 90