Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS

被引:4
|
作者
Xiaoying Li
Xingfa Gu
Xiangjun Min
Tao Yu
Qiaoyan Fu
Yong Zhang
Xiaowen Li
机构
[1] Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University,State Key Laboratory of Remote Sensing Science
[2] Graduate University of Chinese Academy of Sciences,Institut National de la Recherche Agronomique
[3] The Center for National Spaceborne Demonstration,undefined
[4] Climat Sol Environnement,undefined
[5] China Center for Resource Satellite Data and Application,undefined
来源
关键词
CBERS-02; CCD camera; cross-calibration; the spectral band matching factors;
D O I
10.1007/BF03039424
中图分类号
学科分类号
摘要
For the application of the CCD camera, the most important payload on CBERS-02, the key is to provide long-term stable radiometric calibration coefficients. Although the vicarious calibration had been proved successful, it had its limitations such as test site requirement and unsuitable for historical data. Cross-calibration is one of the alternative methods, but it needs synchro surface spectrum to achieve spectral band matching factors. Our effort is to probe the influences on these factors. Simulations with a lot of surface spectrum showed that the factors changed with the viewing geometry, atmospheric condition and surface targets. However, simulating with the same viewing geometry and atmospheric condition, the spectral band matching factors of the same or similar surface targets, spectrum acquired from different dates and different places would like to be consistent to each other within 1%–5%. Thus, the synchro measurement data can be substituted by the same or similar target from other source. Based on this method, using the MODIS as the reference, the cross-calibration was performed for CCD camera. The research demonstrated that the traditional method with single calibration site was inappropriate for CCD camera, since the offsets for its four spectral bands were not zeros. With four calibration sites, these offsets were obtained. And the camera was detected to degrade with dates based on four times of cross-calibrations.
引用
收藏
页码:44 / 60
页数:16
相关论文
共 50 条
  • [41] Uncertainty analysis of cross-calibration for HJ-1 CCD camera
    Wang Zuo
    Xiao PengFeng
    Gu XingFa
    Feng XueZhi
    Li XiaoYing
    Gao HaiLiang
    Li Hui
    Lin JinTang
    Zhang XueLiang
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2013, 56 (03) : 713 - 723
  • [42] RADIOMETRIC CCD CAMERA CALIBRATION AND NOISE ESTIMATION
    HEALEY, GE
    KONDEPUDY, R
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1994, 16 (03) : 267 - 276
  • [43] Cross-Calibration of GF-1 PMS Sensor With Landsat 8 OLI and Terra MODIS
    Gao, Hailiang
    Gu, Xingfa
    Yu, Tao
    Sun, Yuan
    Liu, Qiyue
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2016, 54 (08): : 4847 - 4854
  • [44] Cross-calibration of MSG1-SEVIRI infrared channels with Terra-MODIS channels
    Jiang, G. -M.
    Li, Z. -L.
    [J]. INTERNATIONAL JOURNAL OF REMOTE SENSING, 2009, 30 (03) : 753 - 769
  • [45] Multitemporal cross-calibration of GF-1 WFV and Terra MODIS reflective solar bands
    Liu, Li
    Shi, Tingting
    Han, Qijin
    Zhang, Xuewen
    [J]. INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGING SPECTROSCOPY; AND TELESCOPES AND LARGE OPTICS, 2014, 9298
  • [46] Cross-Calibration between ASTER and MODIS Visible to Near-Infrared Bands for Improvement of ASTER Radiometric Calibration
    Obata, Kenta
    Tsuchida, Satoshi
    Yamamoto, Hirokazu
    Thome, Kurtis
    [J]. SENSORS, 2017, 17 (08)
  • [47] Multitemporal Cross-Calibration of the Terra MODIS and Landsat 7 ETM+ Reflective Solar Bands
    Angal, Amit
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chander, Gyanesh
    Choi, Taeyoung
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (04): : 1870 - 1882
  • [48] 用CBERS-02卫星和MODIS数据联合反演地表蒸散通量
    辛晓洲
    柳钦火
    唐勇
    田国良
    顾行发
    李小文
    张宏升
    陈家宜
    [J]. 中国科学:技术科学, 2005, (S1) : 125 - 140
  • [49] Cross-calibration of the Oceansat-2 Ocean Colour Monitor (OCM) with Terra and Aqua MODIS
    Angal, Amit
    Brinkmann, Jake
    Kumar, A. Senthil
    Xiong, Xiaoxiong
    [J]. EARTH OBSERVING MISSIONS AND SENSORS: DEVELOPMENT, IMPLEMENTATION, AND CHARACTERIZATION IV, 2016, 9881
  • [50] 一种CBERS-02星CCD原始条带噪声处理方法
    宋燕
    刘团结
    丁赤飚
    [J]. 遥感技术与应用, 2008, (04) : 457 - 461