The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels

被引:22
|
作者
Gao, Caixia [1 ,2 ]
Jiang, Xiaoguang [1 ,2 ]
Li, Xianbin [3 ]
Li, Xiaohui [1 ]
机构
[1] Chinese Acad Sci, Acad Optoelect, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst Opt & Elect, Chengdu 610209, Peoples R China
基金
中国国家自然科学基金;
关键词
ABSOLUTE CALIBRATION; REFLECTANCE;
D O I
10.1080/01431161.2012.716531
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remote-sensing data. This article attempts to cross-calibrate the visible and near-infrared channels 1 (450-520 nm), 2 (520-590 nm), 3 (630-690 nm), and 4 (770-890 nm) of the China-Brazil Earth Resources Satellite (CBERS)-02B/charge-coupled device (CCD) camera with channels 3 (459-479 nm), 4 (545-565 nm), 1 (620-670 nm), and 2 (841-876 nm) of the Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), respectively. The radiative transfer modelling (RTM) method is implemented using the CBERS-02B/CCD and Terra/MODIS measurements at the Dunhuang radiometric calibration site in October 2008. The differences between the cross-calibration and vicarious calibration techniques for channels 1, 2, 3, and 4 are 11.15%, -0.89%, 2.88%, and 11.28%, respectively. Furthermore, the accuracies of the cross-calibration coefficients of CBERS-02B/CCD are analysed, wherein the results indicate that the calibration uncertainty is within 5%.
引用
收藏
页码:3688 / 3698
页数:11
相关论文
共 44 条
  • [1] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Xiaoying Li
    Xingfa Gu
    Xiangjun Min
    Tao Yu
    Qiaoyan Fu
    Yong Zhang
    Xiaowen Li
    [J]. Science in China Series E Engineering & Materials Science, 2005, 48 (Suppl 2): : 44 - 60
  • [2] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    LI Xiaoying GU Xingfa MIN Xiangjun YU Tao FU Qiaoyan ZHANG Yong LI Xiaowen State Key Laboratory of Remote Sensing Science Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University Beijing China Graduate University of Chinese Academy of Sciences Beijing China The Center for National Spaceborne Demonstration Beijing China Institut National de la Recherche Agronomique Climat Sol Environnement Avignon France China Center for Resource Satellite Data and Application Beijing China
    [J]. Science in China(Series E:Technological Sciences), 2005, (Series E:Technological Sciences) : 44 - 60
  • [3] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    LI Xiaoying1
    2. Graduate University of Chinese Academy of Sciences
    3. The Center for National Spaceborne Demonstration
    4. Institut National de la Recherche Agronomique
    5. China Center for Resource Satellite Data and Application
    [J]. Science China Technological Sciences, 2005, (S2) : 44 - 60
  • [4] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Li, XY
    Gu, XF
    Min, XJ
    Yu, TA
    Fu, QY
    Zhang, Y
    Li, XW
    [J]. SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 : 44 - 60
  • [5] Cross-calibration of MSG1-SEVIRI infrared channels with Terra-MODIS channels
    Jiang, G. -M.
    Li, Z. -L.
    [J]. INTERNATIONAL JOURNAL OF REMOTE SENSING, 2009, 30 (03) : 753 - 769
  • [6] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    Junwu Tang
    Xingfa Gu
    Shengli Niu
    Chaofei Ma
    Xiangjun Min
    [J]. Science in China Series E Engineering & Materials Science, 2005, 48 (Suppl 2): : 61 - 71
  • [7] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    TANG Junwu1
    2. State Key Laboratory of Remote Sensing Science
    3. China Center for Resource Satellite Data and Applications (CRESDA)
    [J]. Science China Technological Sciences, 2005, (S2) : 61 - 71
  • [8] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    Tang, JW
    Gu, XF
    Niu, SL
    Ma, CF
    Min, XJ
    [J]. SCIENCE IN CHINA SERIES E-ENGINEERING & MATERIALS SCIENCE, 2005, 48 : 61 - 71
  • [9] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    TANG Junwu GU Xingfa NIU Shengli MA Chaofei MIN Xiangjun National Satellite Ocean Application Service NSOAS Beijing China State Key Laboratory of Remote Sensing Science Beijing China China Center for Resource Satellite Data and Applications CRESDA Beijing China
    [J]. Science in China(Series E:Technological Sciences), 2005, (Series E:Technological Sciences) : 61 - 71
  • [10] Cross-calibration of FY-2E/VISSR infrared window and water vapor channels with TERRA/MODIS
    Xu Na
    Hu Xiu-Qing
    Chen Lin
    Zhang Yu-Xiang
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (04) : 319 - +