Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS

被引:0
|
作者
LI Xiaoying GU Xingfa MIN Xiangjun YU Tao FU Qiaoyan ZHANG Yong LI Xiaowen State Key Laboratory of Remote Sensing Science Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University Beijing China Graduate University of Chinese Academy of Sciences Beijing China The Center for National Spaceborne Demonstration Beijing China Institut National de la Recherche Agronomique Climat Sol Environnement Avignon France China Center for Resource Satellite Data and Application Beijing China [1 ,2 ,3 ,1 ,3 ,4 ,5 ,1 ,3 ,5 ,1 ,2 ,3 ,1 ,3 ,1 ,100101 ,2 ,100039 ,3 ,100101 ,4 ,84914 ,5 ,100830 ]
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
For the application of the CCD camera, the most important payload on CBERS-02, the key is to provide long-term stable radiometric calibration coefficients. Although the vicarious calibration had been proved successful, it had its limitations such as test site requirement and unsuitable for historical data. Cross-calibration is one of the alternative methods, but it needs synchro surface spectrum to achieve spectral band matching factors. Our effort is to probe the influences on these factors. Simulations with a lot of surface spectrum showed that the factors changed with the viewing geometry, atmospheric condition and surface targets. However, simulating with the same viewing geometry and atmospheric condition, the spectral band matching factors of the same or similar surface targets’ spectrum acquired from different dates and different places would like to be consistent to each other within 1%―5%. Thus, the synchro measurement data can be substituted by the same or similar target from other source. Based on this method, using the MODIS as the reference, the cross-calibration was performed for CCD camera. The research demonstrated that the traditional method with single calibration site was inappropriate for CCD camera, since the offsets for its four spectral bands were not zeros. With four calibration sites, these offsets were obtained. And the camera was detected to degrade with dates based on four times of cross-calibrations.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Xiaoying Li
    Xingfa Gu
    Xiangjun Min
    Tao Yu
    Qiaoyan Fu
    Yong Zhang
    Xiaowen Li
    [J]. Science in China Series E Engineering & Materials Science, 2005, 48 (Suppl 2): : 44 - 60
  • [2] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    LI Xiaoying1
    2. Graduate University of Chinese Academy of Sciences
    3. The Center for National Spaceborne Demonstration
    4. Institut National de la Recherche Agronomique
    5. China Center for Resource Satellite Data and Application
    [J]. Science China Technological Sciences, 2005, (S2) : 44 - 60
  • [3] Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS
    Li, XY
    Gu, XF
    Min, XJ
    Yu, TA
    Fu, QY
    Zhang, Y
    Li, XW
    [J]. SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 : 44 - 60
  • [4] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    Junwu Tang
    Xingfa Gu
    Shengli Niu
    Chaofei Ma
    Xiangjun Min
    [J]. Science in China Series E Engineering & Materials Science, 2005, 48 (Suppl 2): : 61 - 71
  • [5] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    TANG Junwu GU Xingfa NIU Shengli MA Chaofei MIN Xiangjun National Satellite Ocean Application Service NSOAS Beijing China State Key Laboratory of Remote Sensing Science Beijing China China Center for Resource Satellite Data and Applications CRESDA Beijing China
    [J]. Science in China(Series E:Technological Sciences), 2005, (Series E:Technological Sciences) - 71
  • [6] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    TANG Junwu1
    2. State Key Laboratory of Remote Sensing Science
    3. China Center for Resource Satellite Data and Applications (CRESDA)
    [J]. Science China Technological Sciences, 2005, (S2) : 61 - 71
  • [7] Water target based cross-calibration of CBERS-02 CCD camera with MODIS data
    Tang, JW
    Gu, XF
    Niu, SL
    Ma, CF
    Min, XJ
    [J]. SCIENCE IN CHINA SERIES E-ENGINEERING & MATERIALS SCIENCE, 2005, 48 : 61 - 71
  • [8] Radiometric cross-calibration of CBERS-02 IRMSS thermal channel
    Zhang Yong
    Gu Xing-Fa
    Yu Tao
    Zhang Yu-Xiang
    Qi Rui-Li
    Li Xiao-Wen
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2006, 25 (04) : 261 - 266
  • [9] Radiometric cross-calibration of Terra ASTER and MODIS
    Yuan, Karen
    Thome, Kurt
    McCorkel, Joel
    [J]. EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [10] The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels
    Gao, Caixia
    Jiang, Xiaoguang
    Li, Xianbin
    Li, Xiaohui
    [J]. INTERNATIONAL JOURNAL OF REMOTE SENSING, 2013, 34 (9-10) : 3688 - 3698