The cross-calibration of CBERS-02B/CCD visible-near infrared channels with Terra/MODIS channels

被引:22
|
作者
Gao, Caixia [1 ,2 ]
Jiang, Xiaoguang [1 ,2 ]
Li, Xianbin [3 ]
Li, Xiaohui [1 ]
机构
[1] Chinese Acad Sci, Acad Optoelect, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst Opt & Elect, Chengdu 610209, Peoples R China
基金
中国国家自然科学基金;
关键词
ABSOLUTE CALIBRATION; REFLECTANCE;
D O I
10.1080/01431161.2012.716531
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remote-sensing data. This article attempts to cross-calibrate the visible and near-infrared channels 1 (450-520 nm), 2 (520-590 nm), 3 (630-690 nm), and 4 (770-890 nm) of the China-Brazil Earth Resources Satellite (CBERS)-02B/charge-coupled device (CCD) camera with channels 3 (459-479 nm), 4 (545-565 nm), 1 (620-670 nm), and 2 (841-876 nm) of the Terra/Moderate Resolution Imaging Spectroradiometer (MODIS), respectively. The radiative transfer modelling (RTM) method is implemented using the CBERS-02B/CCD and Terra/MODIS measurements at the Dunhuang radiometric calibration site in October 2008. The differences between the cross-calibration and vicarious calibration techniques for channels 1, 2, 3, and 4 are 11.15%, -0.89%, 2.88%, and 11.28%, respectively. Furthermore, the accuracies of the cross-calibration coefficients of CBERS-02B/CCD are analysed, wherein the results indicate that the calibration uncertainty is within 5%.
引用
下载
收藏
页码:3688 / 3698
页数:11
相关论文
共 41 条