Uranium concentration measurements in human blood for some governorates in Iraq using CR-39 track detector

被引:0
|
作者
Nada F. Tawfiq
Lamya T. Ali
Hussain A. Al-Jobouri
机构
[1] AL-Nahrain University,Department of Physics, College of Science
关键词
CR-39; SSNTD; Human blood; Uranium concentration;
D O I
暂无
中图分类号
学科分类号
摘要
The sensitive and simple technique of fission track etch has been applied to determine trace concentration of uranium in blood samples for occupational and non-occupational workers, male and female, using CR-39 track detector that is employed for registration of induced fission tracks. The results show that the highest recorded uranium concentration in human blood of workers in the ministry of Science and Technology were 1.90 ppb (male, 36 years old, 12 years' work experience, and living in Basrah governorate) and minimum concentration 0.26 ppb (female, 40 years old, 10 years' work experience, and living in Baghdad), while for non-occupational worker, the maximum uranium concentration was 1.76 ppb (female, 63 years old, and living in Al-Muthana) and minimum concentration was 0.28 ppb (female, 20 years old, and living in Baghdad). It has also been found that the uranium concentration in human blood samples of workers in the ministry of Science and Technology are higher than those of non-occupational workers, and the uranium concentrations for female workers and for non-occupational workers were higher than those for male workers and non-occupational workers.
引用
收藏
页码:671 / 674
页数:3
相关论文
共 50 条
  • [41] Measurement of alpha particle range in CR-39 detector using nuclear track profiles
    EL-Araby, Entesar H.
    Shabaan, Doaa H.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (01) : 139 - 144
  • [42] ESTIMATION OF URANIUM CONTAMINATION IN ALUMINUM FOILS BY CR-39 TRACK DETECTORS
    PITT, E
    SCHARMANN, A
    WERNER, B
    SELDERS, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 805 - 808
  • [43] Single-ion detection using nuclear track detector CR-39 plastic
    Hara, K
    Koh, M
    Matsukawa, T
    Tanii, T
    Ohdomari, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (12): : 4536 - 4538
  • [44] A new approach for high-dose measurement using CR-39 track detector
    G. S. Sahoo
    S. P. Tripathy
    Rahul Roy
    D. S. Joshi
    M. S. Kulkarni
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 325 : 765 - 771
  • [45] MEASUREMENTS OF RADON IN DWELLINGS WITH CR-39 TRACK DETECTORS.
    Majborn, B.
    Nuclear tracks, 1985, 12 (1-6): : 763 - 766
  • [46] MEASUREMENTS OF TRANSVERSAL ETCHING RATES OF URANIUM TRACKS IN CR-39
    HEYNA, U
    ENGE, W
    SERMUND, G
    BEAUJEAN, R
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 33 - 36
  • [47] Proton beam dosimetry by CR-39 track-etched detector
    Ghergherehchi, M.
    Afarideh, H.
    Maraghe, M. Ghanadi
    Mohammadzadeh, A.
    Esmaeilnezhad, M.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2008, 6 (03): : 121 - 127
  • [48] Empirical model of alpha particle track length in CR-39 detector
    Al-Jubbori, Mushtaq Abed
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 871 : 54 - 58
  • [49] Optical density of the etched α-tracks in CR-39 nuclear track detector
    El Hofy, M
    Elsamman, H
    RADIATION MEASUREMENTS, 1998, 29 (05) : 461 - 464
  • [50] THE EFFECT OF ENVIRONMENTAL TREATMENT ON THE TRACK RESPONSE OF THE CR-39 PLASTIC DETECTOR
    ABOUELKHIER, AAA
    GABER, M
    MAHMOUD, SA
    ELSHAFEY, E
    MATERIALS LETTERS, 1995, 24 (1-3) : 41 - 45