Uranium concentration measurements in human blood for some governorates in Iraq using CR-39 track detector

被引:0
|
作者
Nada F. Tawfiq
Lamya T. Ali
Hussain A. Al-Jobouri
机构
[1] AL-Nahrain University,Department of Physics, College of Science
关键词
CR-39; SSNTD; Human blood; Uranium concentration;
D O I
暂无
中图分类号
学科分类号
摘要
The sensitive and simple technique of fission track etch has been applied to determine trace concentration of uranium in blood samples for occupational and non-occupational workers, male and female, using CR-39 track detector that is employed for registration of induced fission tracks. The results show that the highest recorded uranium concentration in human blood of workers in the ministry of Science and Technology were 1.90 ppb (male, 36 years old, 12 years' work experience, and living in Basrah governorate) and minimum concentration 0.26 ppb (female, 40 years old, 10 years' work experience, and living in Baghdad), while for non-occupational worker, the maximum uranium concentration was 1.76 ppb (female, 63 years old, and living in Al-Muthana) and minimum concentration was 0.28 ppb (female, 20 years old, and living in Baghdad). It has also been found that the uranium concentration in human blood samples of workers in the ministry of Science and Technology are higher than those of non-occupational workers, and the uranium concentrations for female workers and for non-occupational workers were higher than those for male workers and non-occupational workers.
引用
收藏
页码:671 / 674
页数:3
相关论文
共 50 条
  • [31] Calibration of CR-39 solid state nuclear track detector
    Wanabongse, P.
    Sola, B.
    Jamsangtong, J.
    Rattanabussayaporn, S.
    INDIAN JOURNAL OF PHYSICS, 2009, 83 (06) : 833 - 837
  • [32] TRACK-REGISTRATION-AND-DEVELOPMENT CHARACTERISTICS OF CR-39 PLASTIC TRACK DETECTOR
    KHAN, HA
    BRANDT, R
    KHAN, NA
    JAMIL, K
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1983, 7 (03): : 129 - &
  • [33] B-10 CONCENTRATION MEASUREMENTS USING THE SOLID-STATE NUCLEAR TRACK DETECTOR CR-39 AND AUTOMATIC IMAGE-ANALYSIS
    BLUE, TE
    ROBERTS, TC
    BARTH, RF
    TALNAGI, JW
    ALAM, F
    NUCLEAR TECHNOLOGY, 1987, 77 (02) : 220 - 226
  • [34] SENSITIVITY OF RADON MEASUREMENTS WITH CR-39 TRACK ETCH DETECTOR - A MONTE-CARLO STUDY
    NIKEZIC, D
    KOSTIC, D
    KRSTIC, D
    SAVOVIC, S
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 647 - 648
  • [35] RADON ESTIMATION IN SOME INDIAN TOBACCO, TEA AND TOOTH POWDER USING CR-39 NUCLEAR TRACK DETECTOR
    KHAN, AJ
    SHARMA, KC
    VARSHNEY, AK
    PRASAD, R
    TYAGI, RK
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1988, 27 (03) : 233 - 237
  • [36] Some more new etchants for CR-39 detector
    Matiullah
    Rehman, S
    Rehman, S
    Mati, N
    Ahmad, S
    RADIATION MEASUREMENTS, 2005, 39 (05) : 551 - 555
  • [37] THE MEASUREMENT OF AIRBORNE ALPHA-PARTICLES USING A CR-39 NUCLEAR TRACK DETECTOR
    WONG, CF
    ESPIE, N
    MEARA, LA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03): : 569 - 573
  • [38] A Study of the Optical Characteristics of CR-39 Nuclear Track Detector Using Ultraviolet Irradiation
    Al-Nagaar, Tayseer, I
    Shabaan, Doaa H.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2021, 54 (04): : 85 - 88
  • [39] A new approach for high-dose measurement using CR-39 track detector
    Sahoo, G. S.
    Tripathy, S. P.
    Roy, Rahul
    Joshi, D. S.
    Kulkarni, M. S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 325 (03) : 765 - 771
  • [40] SOME ENVIRONMENTAL-EFFECT STUDIES ON THE RESPONSE OF CR-39 (DOP) PLASTIC TRACK DETECTOR
    KUMAR, S
    CHANDER, S
    YADAV, JS
    SHARMA, AP
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 129 - 132