Uranium concentration measurements in human blood for some governorates in Iraq using CR-39 track detector

被引:0
|
作者
Nada F. Tawfiq
Lamya T. Ali
Hussain A. Al-Jobouri
机构
[1] AL-Nahrain University,Department of Physics, College of Science
关键词
CR-39; SSNTD; Human blood; Uranium concentration;
D O I
暂无
中图分类号
学科分类号
摘要
The sensitive and simple technique of fission track etch has been applied to determine trace concentration of uranium in blood samples for occupational and non-occupational workers, male and female, using CR-39 track detector that is employed for registration of induced fission tracks. The results show that the highest recorded uranium concentration in human blood of workers in the ministry of Science and Technology were 1.90 ppb (male, 36 years old, 12 years' work experience, and living in Basrah governorate) and minimum concentration 0.26 ppb (female, 40 years old, 10 years' work experience, and living in Baghdad), while for non-occupational worker, the maximum uranium concentration was 1.76 ppb (female, 63 years old, and living in Al-Muthana) and minimum concentration was 0.28 ppb (female, 20 years old, and living in Baghdad). It has also been found that the uranium concentration in human blood samples of workers in the ministry of Science and Technology are higher than those of non-occupational workers, and the uranium concentrations for female workers and for non-occupational workers were higher than those for male workers and non-occupational workers.
引用
收藏
页码:671 / 674
页数:3
相关论文
共 50 条
  • [21] Measuring Radon Concentration Levels in Fertilizers using CR-39 Detector
    Aswood, Murtadha Sh
    Jaafar, Mohamad S.
    Bauk, Sabar
    MICRO/NANO SCIENCE AND ENGINEERING, 2014, 925 : 610 - +
  • [22] Using UV Irradiation to Shorten Track Formation Time on CR-39 Detector
    El-Farrash, A. H.
    Abdelghany, A. M.
    Yousef, Hesham A.
    Mekhimar, M.
    Najim, S. M.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2015, 6 (06):
  • [23] FAST-NEUTRON DOSIMETRY USING A CR-39 PLASTIC TRACK DETECTOR
    KHAN, HA
    KHAN, NA
    NUCLEAR INSTRUMENTS & METHODS, 1980, 178 (2-3): : 491 - 497
  • [24] Mass resolution for iron isotopes in CR-39 track detector
    Kodaira, S
    Hasebe, N
    Doke, T
    Kitagawa, A
    Kitamura, H
    Sato, S
    Uchihori, Y
    Yasuda, N
    Ogura, K
    Tawara, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2004, 43 (9A): : 6358 - 6363
  • [25] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [26] Calibration study on the triton response of CR-39 track detector
    Yamauchi, T
    Oda, K
    Tanabe, S
    Matsumoto, H
    Miyake, H
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 191 - 196
  • [27] APPLICATIONS OF CR-39 NUCLEAR TRACK DETECTOR IN MEDICINE AND TECHNOLOGY
    HENSHAW, DL
    PHYSICS IN TECHNOLOGY, 1982, 13 (06): : 266 - &
  • [29] A METHOD TO PROTECT CR-39 TRACK DETECTOR FROM SUNLIGHT
    AHMAD, N
    MIRZA, NM
    MIRZA, SM
    TUFAIL, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (07): : 1521 - 1522
  • [30] Calibration of solid state nuclear track detector CR-39
    Ren, GX
    Jing, GR
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (06): : 596 - 598