A Method for Assessing the Effect of Metal Artifact Reduction Algorithms on Quantitative Characteristics of CT Images

被引:0
|
作者
Yu. A. Vasilev
D. S. Semenov
E. S. Akhmad
O. Yu. Panina
K. A. Sergunova
A. V. Petraikin
机构
[1] Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Healthcare Department,
来源
Biomedical Engineering | 2020年 / 54卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The effect of metal artifact reduction algorithms on CT image quality was considered. The mean signal intensities and noise levels were compared for objects with different X-ray densities and spatial positions using phantom modeling. It was shown that, despite an improvement in the visual characteristics of the images, their quantitative characteristics may deteriorate: the change in the mean density reached in some cases 15%; the increase in noise, 30%.
引用
收藏
页码:285 / 288
页数:3
相关论文
共 50 条
  • [31] Deep Sinogram Completion With Image Prior for Metal Artifact Reduction in CT Images
    Yu, Lequan
    Zhang, Zhicheng
    Li, Xiaomeng
    Xing, Lei
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (01) : 228 - 238
  • [32] Metal artifact reduction in dental CT images using polar mathematical morphology
    Naranjo, Valery
    Llorens, Roberto
    Alcaniz, Mariano
    Lopez-Mir, Fernando
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2011, 102 (01) : 64 - 74
  • [33] Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images
    Huang, V.
    Kohli, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3244 - 3244
  • [34] Evaluation of the quality of CT images acquired with smart metal artifact reduction software
    Zhou, Peng
    Zhang, Chunling
    Gao, Zhen
    Cai, Wangshu
    Yan, Deyue
    Wei, Zhaolong
    OPEN LIFE SCIENCES, 2018, 13 (01): : 155 - 162
  • [35] The λ-MLEM algorithm:: An iterative reconstruction technique for metal artifact reduction in CT images
    Oehler, May
    Buzug, Thorsten M.
    ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 42 - +
  • [36] Quantitative Evaluation of the Smart Metal Artifact Reduction (SMAR) for CT Simulation in Radiotherapy
    Fan, J.
    Xu, Q.
    Chen, X.
    Eldib, A.
    Jin, L.
    Wang, L.
    Liu, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E226 - E227
  • [37] Validation of a Metal Artifact Reduction Method Based on 3D Conditional GANs for CT Images of the Ear
    Wang, Jianing
    Chakravorti, Srijata
    Zhao, Yiyuan
    Noble, Jack H.
    Dawant, Benoit M.
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [38] A metal artifact reduction method for small field of view CT imaging
    Choi, Seungwon
    Moon, Seunghyuk
    Baek, Jongduk
    PLOS ONE, 2021, 16 (01):
  • [39] A comparative study of 2D metal artifact reduction algorithms in medical CT
    Watzke, O
    Kachelriess, M
    Kalender, WA
    RADIOLOGY, 2000, 217 : 313 - 313
  • [40] Metal Artifact Reduction Algorithms for CT in the Trauma Setting: Do They Take Too Long?
    Rose, S.
    Lipford, M.
    Stabo, N.
    Bartels, C.
    Lubner, M.
    Szczykutowicz, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E543 - E543