The λ-MLEM algorithm:: An iterative reconstruction technique for metal artifact reduction in CT images

被引:0
|
作者
Oehler, May [1 ]
Buzug, Thorsten M. [2 ]
机构
[1] RheinAhrCampus Remagen, Dept Math & Technol, Suedallee 2, D-53424 Remagen, Germany
[2] Univ Lubeck, Inst Med Engn, D-23538 Lubeck, Germany
来源
ADVANCES IN MEDICAL ENGINEERING | 2007年 / 114卷
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Filtered backprojection (FBP) is an inadequate method to cope with inconsistencies in Radon space and, consequently, leads to artifacts in reconstructed CT images. A solution to this problem is given by statistical reconstruction methods like the Maximum-Likelihood Expectation-Maximization (MLEM) algorithm. The advantage of MLEM is that it allows to weight raw projection data during reconstruction. The method presented here consists of two steps. In a first step, inconsistent data in the Radon space were bridged using a directional interpolation scheme. Since these surrogate data are contaminated with residual inconsistencies, in a second step, the image is reconstructed using a weighted MLEM algorithm. In this work, the modified MLEM algorithm for metal artifact reduction in CT is presented for clinical hip prosthesis data. On the basis of image entropy the reconstruction success is evaluated.
引用
收藏
页码:42 / +
页数:2
相关论文
共 50 条
  • [1] Two step MLEM algorithm for artifact reduction in CT images
    Oehler, M.
    Buzug, T. M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S38 - S41
  • [2] CT Metal Artifact Reduction in the Spine: Can an Iterative Reconstruction Technique Improve Visualization?
    Kotsenas, A. L.
    Michalak, G. J.
    DeLone, D. R.
    Diehn, F. E.
    Grant, K.
    Halaweish, A. F.
    Krauss, A.
    Raupach, R.
    Schmidt, B.
    McCollough, C. H.
    Fletcher, J. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (11) : 2184 - 2190
  • [3] Iterative CT reconstruction of real data with metal artifact reduction
    Hamelin, Benoit
    Goussard, Yves
    Gendron, David
    Dussault, Jean-Pierre
    Cloutier, Guy
    Beaudoin, Gilles
    Soulez, Gilles
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1453 - +
  • [4] Metal pin artifact reduction with masked iterative nano-CT reconstruction
    Li, Mengzhou
    Cooley, Victoria
    Nikitin, Viktor
    Stock, Stuart R.
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [5] Modified MLEM Algorithm for Artifact Suppression in CT
    Oehler, May
    Buzug, Thorsten M.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3511 - 3518
  • [6] Iterative deblurring for CT metal artifact reduction
    Wang, G
    Snyder, DL
    OSullivan, JA
    Vannier, MW
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) : 657 - 664
  • [7] Fast iterative algorithm for metal artifact reduction in X-ray CT
    Wang, G
    Frei, T
    Vannier, MW
    ACADEMIC RADIOLOGY, 2000, 7 (08) : 607 - 614
  • [8] Clinical Evaluation of the Iterative Metal Artifact Reduction Algorithm for CT Simulation in Radiotherapy
    Axente, M.
    Lee, K.
    Paidi, A.
    Bani-Hashemi, A.
    Hristov, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy
    Axente, Marian
    Paidi, Ajay
    Von Eyben, Rie
    Zeng, Chuan
    Bani-Hashemi, Ali
    Krauss, Andreas
    Hristov, Dimitre
    MEDICAL PHYSICS, 2015, 42 (03) : 1170 - 1183
  • [10] REDUCTION OF BLADDER ARTIFACT IN SPECT BY AN ITERATIVE RECONSTRUCTION ALGORITHM
    REULAND, P
    KAISER, W
    MULLERSCHAUENBURG, W
    FEINE, U
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1991, 22 (01): : 23 - 24