The λ-MLEM algorithm:: An iterative reconstruction technique for metal artifact reduction in CT images

被引:0
|
作者
Oehler, May [1 ]
Buzug, Thorsten M. [2 ]
机构
[1] RheinAhrCampus Remagen, Dept Math & Technol, Suedallee 2, D-53424 Remagen, Germany
[2] Univ Lubeck, Inst Med Engn, D-23538 Lubeck, Germany
来源
ADVANCES IN MEDICAL ENGINEERING | 2007年 / 114卷
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Filtered backprojection (FBP) is an inadequate method to cope with inconsistencies in Radon space and, consequently, leads to artifacts in reconstructed CT images. A solution to this problem is given by statistical reconstruction methods like the Maximum-Likelihood Expectation-Maximization (MLEM) algorithm. The advantage of MLEM is that it allows to weight raw projection data during reconstruction. The method presented here consists of two steps. In a first step, inconsistent data in the Radon space were bridged using a directional interpolation scheme. Since these surrogate data are contaminated with residual inconsistencies, in a second step, the image is reconstructed using a weighted MLEM algorithm. In this work, the modified MLEM algorithm for metal artifact reduction in CT is presented for clinical hip prosthesis data. On the basis of image entropy the reconstruction success is evaluated.
引用
收藏
页码:42 / +
页数:2
相关论文
共 50 条
  • [21] Evaluation of the Impact of Using TOF Technique on Metal Artifact Reduction in PET/CT Images
    Sharifpour, R.
    Ghafarian, P.
    Ay, M. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S363 - S364
  • [22] Superiorized polyenergetic reconstruction algorithm for reduction of metal artifacts in CT images
    Humphries, T.
    Gibali, A.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [23] CT image reconstruction algorithm to reduce metal artifact
    Koseki, Michihiko
    Hashimoto, Shuhei
    Sato, Shinpei
    Kimura, Hitoshi
    Inou, Norio
    Nihon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 2006, 72 (12): : 1888 - 1894
  • [24] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Watzke, O
    Kalender, WA
    EUROPEAN RADIOLOGY, 2004, 14 (05) : 849 - 856
  • [25] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Oliver Watzke
    Willi A. Kalender
    European Radiology, 2004, 14 : 849 - 856
  • [26] Advances in metal artifact reduction in CT images: A review of traditional and novel metal artifact reduction techniques
    Selles, Mark
    van Osch, Jochen A. C.
    Maas, Mario
    Boomsma, Martijn F.
    Wellenberg, Ruud H. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170
  • [27] Experimental Evaluation of a Reconstruction Algorithm for Metal Artifact Reduction
    Magnelli, A.
    Xia, P.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [28] A Novel Iterative MLEM Image Reconstruction Algorithm Based on Beltrami Filter: Application to ECT Images
    Boudjelal, Abdelwahhab
    Elmoataz, Abderrahim
    Attallah, Bilal
    Messali, Zoubeida
    TOMOGRAPHY, 2021, 7 (03) : 286 - 300
  • [29] A Bone Artifact Reduction Algorithm for Differential Phase-Contrast CT Based On Statistical Iterative Reconstruction
    Hahn, D.
    Thibault, P.
    Noel, P.
    Bech, M.
    Pfeiffer, F.
    MEDICAL PHYSICS, 2012, 39 (06) : 3987 - 3987
  • [30] Metal artifact reduction for small metal implants on CT: Which image reconstruction algorithm performs better?
    Grandmougin, Aurelie
    Bakour, Omar
    Villani, Nicolas
    Baumann, Cedric
    Rousseau, Helene
    Teixeira, Pedro Augusto Gondim
    Blum, Alain
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 127