Cyanide determination in fruit brandies by an amperometric biosensor with immobilised Saccharomyces cerevisiae

被引:0
|
作者
Željka Filipović-Kovačević
Miroslav Mikšaj
Dean Šalamon
机构
[1] Faculty of Food Technology and Biotechnology,
[2] University of Zagreb,undefined
[3] Croatia ,undefined
[4] Podravka d.d.,undefined
[5] Koprivnica,undefined
[6] Croatia,undefined
来源
关键词
Biosensor Cyanide Saccharomyces cerevisiae;
D O I
暂无
中图分类号
学科分类号
摘要
A microbial sensor consisting of immobilised Saccharomyces cerevisiae and an oxygen electrode was applied to determine cyanide content in samples of fruit brandies. The results obtained by biosensor measurements were compared by ISE-potentiometry. The average recovery was 97.8% with standard deviation of 6.8%. This microbial sensor was reused for hours daily (strongly depending on the determined total cyanide concentration).
引用
收藏
页码:347 / 352
页数:5
相关论文
共 50 条
  • [21] Amperometric biosensor for rapid determination of alanine
    Kwan, RCH
    Hon, PYT
    Renneberg, R
    ANALYTICA CHIMICA ACTA, 2004, 523 (01) : 81 - 88
  • [22] AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF ETHANOL VAPOR
    PARK, JK
    YEE, HJ
    KIM, ST
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7): : 587 - 594
  • [23] AMPEROMETRIC DETERMINATION OF PHOSPHATE IONS BY BIOSENSOR
    KULYS, J
    HIGGINS, IJ
    BANNISTER, JV
    BIOSENSORS & BIOELECTRONICS, 1992, 7 (03): : 187 - 191
  • [24] Performance of an amperometric biosensor for the determination of hemoglobin
    Jiang, LY
    Liu, CX
    Li, HQ
    Luo, XB
    Wu, YR
    Cai, XX
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2005, 5 (08) : 1301 - 1304
  • [25] An amperometric biosensor for the determination of organophosphorus pesticides
    Telefoncu, A
    TURKISH JOURNAL OF CHEMISTRY, 1996, 20 (03): : 253 - 257
  • [26] A reagentless biosensor for the amperometric determination of NADH
    Cosnier, S
    Decout, JL
    Fontecave, M
    Frier, C
    Innocent, C
    ELECTROANALYSIS, 1998, 10 (08) : 521 - 525
  • [27] AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF LACTATE IN SWEAT
    FARIDNIA, MH
    PALLESCHI, G
    LUBRANO, GJ
    GUILBAULT, GG
    ANALYTICA CHIMICA ACTA, 1993, 278 (01) : 35 - 40
  • [28] A novel amperometric enzyme inhibition biosensor based on xanthine oxidase immobilised onto glassy carbon electrodes for bisphenol A determination
    Ben Messaoud, Najib
    Ghica, Mariana Emilia
    Dridi, Cherif
    Ben Ali, Mounir
    Brett, Christopher M. A.
    TALANTA, 2018, 184 : 388 - 393
  • [29] Mediated Amperometric Biosensor for the Determination of Ammonium
    Abd Rahman, Samsulida
    Abdullah, Jaafar
    Sidek, Hamidah
    Azmi, Nur Ellina
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (03): : 262 - 276
  • [30] Amperometric Acetylcholinesterase Biosensor for Physostigmine Determination
    Davletshina, R. R.
    Ivanov, A. N.
    Evtugyn, G. A.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2018, 160 (01): : 5 - 16