Performance of an amperometric biosensor for the determination of hemoglobin

被引:13
|
作者
Jiang, LY
Liu, CX
Li, HQ
Luo, XB
Wu, YR
Cai, XX
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100080, Peoples R China
[2] Chinese Acad Sci, Inst Elect, Natl Key Lab Microwave Imaging Technol, Beijing 100080, Peoples R China
[3] Chinese Acad Sci, Grad Sch, Beijing 100080, Peoples R China
关键词
hemoglobin; amperometric biosensor; thin-film electrode;
D O I
10.1166/jnn.2005.213
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Hemoglobin is a very important physiological index in human blood, especially for the evaluation of the physical performance of athletes. This paper reports an amperometric biosensor for the determination of blood hemoglobin, using potassium ferricyanide as a mediator, based on thin-film technology in a two-electrode system. The biosensor can be used for the determination of hemoglobin at concentrations in a linear range of 10-3000 mu M, and the correlation coefficient is 0.996, the relative standard deviation is 2.3% for six determinations for 2000 mu M hemoglobin concentration. And the linear range of hemoglobin is studied using methylene blue as a mediator.
引用
收藏
页码:1301 / 1304
页数:4
相关论文
共 50 条
  • [1] Amperometric biosensor for the determination of creatine
    A. Ramanavicius
    [J]. Analytical and Bioanalytical Chemistry, 2007, 387 : 1899 - 1906
  • [2] Amperometric Biosensor for Phenol Determination
    da Costa Silva, Livia Maria
    Salgado, Andrea Medeiros
    Zarur Coelho, Maria Alice
    [J]. ICHEAP-10: 10TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-3, 2011, 24 : 1249 - +
  • [3] Amperometric biosensor for the determination of creatine
    Ramanavicius, A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (05) : 1899 - 1906
  • [4] Rutin determination at an amperometric biosensor
    Mousty, Christine
    Cosnier, Serge
    Lopez, Marta Sanchez-Paniagua
    Lopez-Cabarcos, Enrique
    Lopez-Ruiz, Beatriz
    [J]. ELECTROANALYSIS, 2007, 19 (2-3) : 253 - 258
  • [5] Hemoglobin-Titanate Composite Based Biosensor for the Amperometric Determination of Hydrogen Peroxide in Acidic Medium
    Wu, Yihua
    Gao, Qiuming
    Shi, Linpu
    Gao, Lu
    [J]. ELECTROANALYSIS, 2009, 21 (08) : 904 - 908
  • [6] AMPEROMETRIC DETERMINATION OF PHOSPHATE IONS BY BIOSENSOR
    KULYS, J
    HIGGINS, IJ
    BANNISTER, JV
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (03): : 187 - 191
  • [7] AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF ETHANOL VAPOR
    PARK, JK
    YEE, HJ
    KIM, ST
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7): : 587 - 594
  • [8] Amperometric biosensor for rapid determination of alanine
    Kwan, RCH
    Hon, PYT
    Renneberg, R
    [J]. ANALYTICA CHIMICA ACTA, 2004, 523 (01) : 81 - 88
  • [9] AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF LACTATE IN SWEAT
    FARIDNIA, MH
    PALLESCHI, G
    LUBRANO, GJ
    GUILBAULT, GG
    [J]. ANALYTICA CHIMICA ACTA, 1993, 278 (01) : 35 - 40
  • [10] A reagentless biosensor for the amperometric determination of NADH
    Cosnier, S
    Decout, JL
    Fontecave, M
    Frier, C
    Innocent, C
    [J]. ELECTROANALYSIS, 1998, 10 (08) : 521 - 525