A novel amperometric enzyme inhibition biosensor based on xanthine oxidase immobilised onto glassy carbon electrodes for bisphenol A determination

被引:23
|
作者
Ben Messaoud, Najib [1 ,2 ]
Ghica, Mariana Emilia [4 ]
Dridi, Cherif [1 ]
Ben Ali, Mounir [1 ,3 ]
Brett, Christopher M. A. [4 ]
机构
[1] Ctr Res Microelect & Nanotechnol CRMN Sousse, NANOMISENE Lab, LR16CRMN01, Technopk Sousse BP 334, Sahloul 4034, Sousse, Tunisia
[2] Univ Sousse, High Sch Sci & Technol Hammam Sousse, Hammam Sousse 4011, Tunisia
[3] Univ Sousse, ISSAT Sousse, Ibn Khaldoun Sousse 4003, Tunisia
[4] Univ Coimbra, Fac Sci & Technol, Dept Chem, P-3004535 Coimbra, Portugal
基金
欧盟第七框架计划;
关键词
Bisphenol A; Enzyme inhibition biosensor; Xanthine oxidase; Fixed potential amperometry; REDUCED GRAPHENE OXIDE; LABEL-FREE DETECTION; ELECTROCHEMICAL BIOSENSOR; ULTRASENSITIVE DETECTION; FILM ELECTRODES; RAPID DETECTION; BABY BOTTLES; TYROSINASE; NANOPARTICLES; SENSOR;
D O I
10.1016/j.talanta.2018.03.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and simple biosensor for the determination of bisphenol A (BPA) based on xanthine oxidase (XOD) enzymatic inhibition has been developed. The biosensor was prepared from xanthine oxidase immobilised by crosslinking with glutaraldehyde, with hypoxanthine as enzyme substrate, and was successfully applied to the determination of BPA using fixed potential amperometry. Biosensor performance was optimised with respect to the applied potential, influence of pH of the electrolyte solution, XOD loading and the substrate concentration. The enzyme inhibition mechanism was evaluated from Cornish-Bowden plus Dixon plots and was found to be reversible and competitive with an apparent inhibition constant of 8.15 nM. Under optimised conditions, the determination of BPA can be achieved in the linear range up to 41 nM with a detection limit of 1.0 nM, which is equal to the lowest reported in the literature, with very good repeatability and reproducibility. The selectivity of the biosensor was evaluated by performing an interference study and found to be excellent; and stability was investigated. It was successfully applied to the detection of BPA in mineral water and in river water.
引用
收藏
页码:388 / 393
页数:6
相关论文
共 50 条
  • [1] A novel amperometric inhibition biosensor based on HRP and gold sononanoparticles immobilised onto Sonogel-Carbon electrode for the determination of sulphides
    Attar, Aisha
    Amine, Aziz
    Achi, Fethi
    Bacha, Saliha Bourouina
    Bourouina, Mustapha
    Cubillana-Aguilera, Laura
    Maria Palacios-Santander, Jose
    Baraket, Abdoullatif
    Errachid, Abdelhamid
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (06) : 515 - 529
  • [2] Amperometric glucose biosensor based on the deposition of copper and glucose oxidase onto glassy carbon transducer
    Rodriguez, MC
    Rivas, GA
    [J]. ANALYTICAL LETTERS, 2000, 33 (12) : 2373 - 2389
  • [3] Amperometric biosensor for hypoxanthine based on immobilized xanthine oxidase on nanocrystal gold-carbon paste electrodes
    Agüi, L
    Manso, J
    Yáñez-Sedeño, P
    Pingarrón, JM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01): : 272 - 280
  • [4] Highly Sensitive Choline Oxidase Enzyme Inhibition Biosensor for Lead Ions Based on Multiwalled Carbon Nanotube Modified Glassy Carbon Electrodes
    Magar, Hend Samy
    Ghica, Mariana Emilia
    Abbas, Mohammed Nooredeen
    Brett, Christopher M. A.
    [J]. ELECTROANALYSIS, 2017, 29 (07) : 1741 - 1748
  • [5] Amperometric xanthine biosensors using glassy carbon electrodes modified with electrografted porous silica nanomaterials loaded with xanthine oxidase
    Maroua Saadaoui
    Alfredo Sánchez
    Paula Díez
    Noureddine Raouafi
    José M. Pingarrón
    Reynaldo Villalonga
    [J]. Microchimica Acta, 2016, 183 : 2023 - 2030
  • [6] Amperometric xanthine biosensors using glassy carbon electrodes modified with electrografted porous silica nanomaterials loaded with xanthine oxidase
    Saadaoui, Maroua
    Sanchez, Alfredo
    Diez, Paula
    Raouafi, Noureddine
    Pingarron, Jose M.
    Villalonga, Reynaldo
    [J]. MICROCHIMICA ACTA, 2016, 183 (06) : 2023 - 2030
  • [7] Amperometric biosensor for hypoxanthine based on immobilized xanthine oxidase on iron (III) meso-tetraphenylporphyrin nanoparticles modified glassy carbon electrode
    Li, Xiao-Hua
    Xie, Zong-Hong
    Min, Hong
    Xian, Yue-Zhong
    Jin, Li-Tong
    [J]. ANALYTICAL LETTERS, 2008, 41 (03) : 456 - 468
  • [8] A novel combined thermometric and amperometric biosensor for lactose determination based on immobilised cellobiose dehydrogenase
    Yakovleva, Maria
    Buzas, Orsolya
    Matsumura, Hirotoshi
    Samejima, Masahiro
    Igarashi, Kiyohiko
    Larsson, Per-Olof
    Gorton, Lo
    Danielsson, Bengt
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 251 - 256
  • [9] An inhibition type amperometric biosensor based on tyrosinase enzyme for fluoride determination
    Asav, Engin
    Yorganci, Emine
    Akyilmaz, Erol
    [J]. TALANTA, 2009, 78 (02) : 553 - 556
  • [10] CYANIDE DETERMINATION USING AN AMPEROMETRIC BIOSENSOR BASED ON CYTOCHROME-OXIDASE INHIBITION
    AMINE, A
    ALAFANDY, M
    KAUFFMANN, JM
    PEKLI, MN
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (17) : 2822 - 2827