Highly Sensitive Choline Oxidase Enzyme Inhibition Biosensor for Lead Ions Based on Multiwalled Carbon Nanotube Modified Glassy Carbon Electrodes

被引:26
|
作者
Magar, Hend Samy [1 ,2 ]
Ghica, Mariana Emilia [2 ]
Abbas, Mohammed Nooredeen [1 ]
Brett, Christopher M. A. [2 ]
机构
[1] Natl Res Ctr, Appl Organ Chem Dept, Giza, Egypt
[2] Univ Coimbra, Fac Sci & Technol, Dept Chem, P-3004535 Coimbra, Portugal
基金
欧盟第七框架计划;
关键词
amperometric choline biosensor; choline oxidase; electrochemical impedance spectroscopy; inhibition by lead ions; multiwalled carbon nanotubes; HEAVY-METAL IONS; AMPEROMETRIC BIOSENSORS; SELECTIVE ELECTRODE; MERCURY; SENSOR;
D O I
10.1002/elan.201700111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of lead ions by inhibition of choline oxidase enzyme has been evaluated for the first time using an amperometric choline biosensor. Choline oxidase (ChOx) was immobilized on a glassy carbon electrode (GCE) modified with multiwalled carbon nano-tubes (MWCNT) through cross-linking with glutaraldehyde. In the presence of ChOx, choline was enzymatically oxidized into betaine at -0.3V versus Ag/AgCl reference electrode, lead ion inhibition of enzyme activity causing a decrease in the choline oxidation current. The experimental conditions were optimised regarding applied potential, buffer pH, enzyme and substrate concentration and incubation time. Under the best conditions for measurement of the lowest concentrations of lead ions, the ChOx/MWCNT/GCE gave a linear response from 0.1 to 1.0 nM Pb2+ and a detection limit of 0.04 nM. The inhibition of ChOx by lead ions was also studied by electrochemical impedance spectroscopy, but had a narrower linear response range and low sensitivity. The inhibition biosensor exhibited high selectivity towards lead ions and was successfully applied to their determination in tap water samples.
引用
收藏
页码:1741 / 1748
页数:8
相关论文
共 50 条
  • [1] A Mexacarbate Electrochemical Biosensor on Carbon Materials Based on a Functionalized Multiwalled Carbon Nanotube Modified Glassy Carbon Electrode
    Tharini, J.
    Chen, Tse-Wei
    Chen, Shen-Ming
    Saraswathi, R.
    Elshikh, Mohamed S.
    Darwish, Noura M.
    Rwei, Syang-Peng
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 8311 - 8325
  • [2] Pyranose oxidase biosensor based on carbon nanotube (CNT)-modified carbon paste electrodes
    Odaci, Dilek
    Telefoncu, Azmi
    Timur, Suna
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01) : 159 - 165
  • [3] Electrochemical reduction of oxygen on multiwalled carbon nanotube modified glassy carbon electrodes in acid media
    Alexeyeva, Nadezda
    Tammeveski, Kaido
    [J]. ELECTROCHEMICAL AND SOLID STATE LETTERS, 2007, 10 (05) : F18 - F21
  • [4] Amperometric biosensor based on glassy carbon electrode modified with long-length carbon nanotube and enzyme
    Furutaka, Hajime
    Nemoto, Kentaro
    Inoue, Yuki
    Hidaka, Hiroki
    Muguruma, Hitoshi
    Inoue, Hitoshi
    Ohsawa, Tatsuya
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (05)
  • [5] Biosensor for arsenite using arsenite oxidase and multiwalled carbon hanotube modified electrodes
    Male, Keith B.
    Hrapovic, Sabahudin
    Santini, Joanne M.
    Luong, John H. T.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (20) : 7831 - 7837
  • [6] A novel amperometric enzyme inhibition biosensor based on xanthine oxidase immobilised onto glassy carbon electrodes for bisphenol A determination
    Ben Messaoud, Najib
    Ghica, Mariana Emilia
    Dridi, Cherif
    Ben Ali, Mounir
    Brett, Christopher M. A.
    [J]. TALANTA, 2018, 184 : 388 - 393
  • [7] Biosensor based on a glassy carbon electrode modified with tyrosinase immmobilized on multiwalled carbon nanotubes
    Ren, Jing
    Kang, Tian-Fang
    Xue, Rui
    Ge, Chao-Nan
    Cheng, Shui-Yuan
    [J]. MICROCHIMICA ACTA, 2011, 174 (3-4) : 303 - 309
  • [8] Biosensor based on a glassy carbon electrode modified with tyrosinase immmobilized on multiwalled carbon nanotubes
    Jing Ren
    Tian-Fang Kang
    Rui Xue
    Chao-Nan Ge
    Shui-Yuan Cheng
    [J]. Microchimica Acta, 2011, 174 : 303 - 309
  • [9] Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Polythionine and Multiwalled Carbon Nanotubes
    Tang, Wenwei
    Li, Lei
    Wu, Lujun
    Gong, Jiemin
    Zeng, Xinping
    [J]. PLOS ONE, 2014, 9 (05):
  • [10] Direct electrochemical conversion of bilirubin oxidase at carbon nanotube-modified glassy carbon electrodes
    Weigel, M. Ch.
    Tritscher, E.
    Lisdat, F.
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (04) : 689 - 693