Experimental study on dynamic performance of coriolis mass flow meter and compensation technology

被引:0
|
作者
Dezhi Zheng
Qiong Nan
Jiying Shi
Shangchun Fan
机构
[1] School of Instrument Science and Opto-electronics Engineering Beihang University,
关键词
Dynamic Performance; Step Response; Solenoid Valve; Ball Valve; LabView Program;
D O I
暂无
中图分类号
学科分类号
摘要
The Coriolis mass flow meter, for its features of directly measuring mass flow and high precision, is widely utilized in the flow measuring fields like batch filling and commercial trade. However, the unsatisfactory dynamic performance is one major constraint to Coriolis mass flow meter from being even more widely used in batch filling industry. To solve the problem, an experimental system which generates refined flow step stimulus signals for Coriolis mass flow meter was designed and based on which experimental and theoretical study on dynamic performances of typical Coriolis mass flow meter was carried out. On top of this, a time-domain recursive digital filter was designed to provide dynamic compensation and the experiments showed this filter can reduce the step response time of Coriolis mass flow meter by about 50%.
引用
收藏
页码:503 / 507
页数:4
相关论文
共 50 条
  • [41] Experimental study of the effects of upstream flow condition upon Venturi flow meter performance
    Aichouni, M
    Laws, EM
    Ouazzane, AK
    FLOW MODELING AND TURBULENCE MEASURMENTS VI, 1996, : 209 - 216
  • [42] Mass flow measurement of oil-water two-phase flow based on coriolis flow meter and SVM
    Ma, Long-Bo
    Zhang, Hong-Jian
    Zhou, Hong-Liang
    He, Qing
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2007, 21 (02): : 200 - 205
  • [43] An experimental study of zero-shift in a straight-tube Coriolis meter
    Ford, C. L.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2020, 76
  • [44] Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter
    van de Ridder, L.
    Hakvoort, Wouter B. J.
    van Dijk, Johannes
    Lotters, Joost C.
    de Boer, Andre
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2016, 138 (03):
  • [45] Coriolis mass-flow meter with integrated multi-DOF active vibration isolation
    van de Ridder, L.
    Hakvoort, W. B. J.
    Brouwer, D. M.
    van Dijk, J.
    Lotters, J. C.
    de Boer, A.
    MECHATRONICS, 2016, 36 : 167 - 179
  • [46] Matrix Pencil Method for Coriolis Mass Flow Meter Signal Processing in Two-Phase Flow Conditions
    Ibryaeva, O.
    Salov, D.
    2017 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2017,
  • [47] Parameter optimization of coriolis mass flow meter in laminar flow regime using Doe-Taguchi method
    Kolhe, Vikram
    Pawar, Suyash
    Chaudhari, Vishal
    Edlabadkar, Ravindra
    Sonawane, Sandipkumar
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (04): : 1026 - 1040
  • [48] Mass Flow Prediction of the Coriolis Meter using C0 Continuous Beam Elements
    Binulal B R
    Akash Rajan
    Abhilash Suryan R
    Jayaraj Kochupillai
    Heuy Dong Kim
    Journal of Thermal Science, 2015, 24 (04) : 398 - 402
  • [49] Mass flow prediction of the coriolis meter using C0 continuous beam elements
    B. R. Binulal
    Akash Rajan
    Suryan R. Abhilash
    Jayaraj Kochupillai
    Heuy Dong Kim
    Journal of Thermal Science, 2015, 24 : 398 - 402
  • [50] Mass Flow Prediction of the Coriolis Meter using C0 Continuous Beam Elements
    Binulal, B. R.
    Rajan, Akash
    Suryan, Abhilash R.
    Kochupillai, Jayaraj
    Kim, Heuy Dong
    JOURNAL OF THERMAL SCIENCE, 2015, 24 (04) : 398 - 402