Experimental study on dynamic performance of coriolis mass flow meter and compensation technology

被引:0
|
作者
Dezhi Zheng
Qiong Nan
Jiying Shi
Shangchun Fan
机构
[1] School of Instrument Science and Opto-electronics Engineering Beihang University,
关键词
Dynamic Performance; Step Response; Solenoid Valve; Ball Valve; LabView Program;
D O I
暂无
中图分类号
学科分类号
摘要
The Coriolis mass flow meter, for its features of directly measuring mass flow and high precision, is widely utilized in the flow measuring fields like batch filling and commercial trade. However, the unsatisfactory dynamic performance is one major constraint to Coriolis mass flow meter from being even more widely used in batch filling industry. To solve the problem, an experimental system which generates refined flow step stimulus signals for Coriolis mass flow meter was designed and based on which experimental and theoretical study on dynamic performances of typical Coriolis mass flow meter was carried out. On top of this, a time-domain recursive digital filter was designed to provide dynamic compensation and the experiments showed this filter can reduce the step response time of Coriolis mass flow meter by about 50%.
引用
收藏
页码:503 / 507
页数:4
相关论文
共 50 条
  • [31] The performance characteristics of a micro-machined Coriolis flow meter: An evaluation by simulation
    Clark, C.
    Wang, S.
    Cheesewright, R.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (06) : 325 - 333
  • [32] A study on an online measurement method to determine the oil discharge ratio by utilizing Coriolis mass flow meter in a calorimeter
    Yan, Gang
    Peng, Leqin
    Wu, Shikai
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 52 : 42 - 50
  • [33] Quantification of the influence of external vibrations on the measurement error of a Coriolis mass-flow meter
    van de Ridder, L.
    Hakvoort, W. B. J.
    van Dijk, J.
    Lotters, J. C.
    de Boer, A.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2014, 40 : 39 - 49
  • [34] A research of dynamic compensation of coriolis mass flowmeter based on BP neural networks
    Zheng, Dezhi
    Peng, Peng
    Fan, Shangchun
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2013, 56 (03) : 365 - 370
  • [35] VIBRATION ISOLATION BY COMPLIANT SENSOR MOUNTING APPLIED TO A CORIOLIS MASS-FLOW METER
    van de Ridder, L.
    Hakvoort, Wouter B. J.
    van Dijk, Johannes
    PROCEEDINGS OF THE ASME 12TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS - 2014, VOL 2, 2014,
  • [36] Non-linear Control of the Oscillation Amplitude of a Coriolis Mass-Flow Meter
    Clarke, D. W.
    EUROPEAN JOURNAL OF CONTROL, 1998, 4 (03) : 196 - 207
  • [37] A research of dynamic compensation of coriolis mass flowmeter based on BP neural networks
    Dezhi Zheng
    Peng Peng
    Shangchun Fan
    Instruments and Experimental Techniques, 2013, 56 : 365 - 370
  • [38] Performance study of Coriolis mass flowmeter for hydrogen two-phase flow measurement
    Pei, Xiangxiang
    Zhang, Xiaobin
    JOURNAL OF FLUIDS AND STRUCTURES, 2025, 133
  • [39] Experimental and simulation studies of the effect of restrictor and distributor on the performance of thermal mass flow meter
    Chaboki, Hossein Hosseinzadeh
    Shahrouzi, Javad Rahbar
    Hassanpour, Ali
    MEASUREMENT, 2018, 119 : 259 - 264
  • [40] Temperature drift characteristics and compensation study of double-winding thermal mass flow meter
    Wang, Qinhui
    Li, Detian
    Hu, Xiangyu
    Cui, Wuyu
    Yang, Lekai
    Wang, Yi
    FLOW MEASUREMENT AND INSTRUMENTATION, 2025, 102