Experimental study on dynamic performance of coriolis mass flow meter and compensation technology

被引:0
|
作者
Dezhi Zheng
Qiong Nan
Jiying Shi
Shangchun Fan
机构
[1] School of Instrument Science and Opto-electronics Engineering Beihang University,
关键词
Dynamic Performance; Step Response; Solenoid Valve; Ball Valve; LabView Program;
D O I
暂无
中图分类号
学科分类号
摘要
The Coriolis mass flow meter, for its features of directly measuring mass flow and high precision, is widely utilized in the flow measuring fields like batch filling and commercial trade. However, the unsatisfactory dynamic performance is one major constraint to Coriolis mass flow meter from being even more widely used in batch filling industry. To solve the problem, an experimental system which generates refined flow step stimulus signals for Coriolis mass flow meter was designed and based on which experimental and theoretical study on dynamic performances of typical Coriolis mass flow meter was carried out. On top of this, a time-domain recursive digital filter was designed to provide dynamic compensation and the experiments showed this filter can reduce the step response time of Coriolis mass flow meter by about 50%.
引用
收藏
页码:503 / 507
页数:4
相关论文
共 50 条
  • [21] Theoretical analysis and experimental study of Coriolis mass flow sensor sensitivity
    Zheng, Dezhi
    Wang, Shuai
    Liu, Bei
    Fan, Shangchun
    JOURNAL OF FLUIDS AND STRUCTURES, 2016, 65 : 295 - 312
  • [22] Dynamic analysis of Coriolis flow meter using Timoshenko beam element
    Binulal, B. R.
    Rajan, Akash
    Kochupillai, Jayaraj
    FLOW MEASUREMENT AND INSTRUMENTATION, 2016, 47 : 100 - 109
  • [23] Two-phase flow metering of heavy oil using a Coriolis mass flow meter: A case study
    Henry, Manus
    Tombs, Michael
    Duta, Mihaela
    Zhou, Feibiao
    Mercado, Ronaldo
    Kenyery, Frank
    Shen, Joseph
    Morles, Martin
    Garcia, Carlos
    Langansan, Robbie
    FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (06) : 399 - 413
  • [24] Failure analysis of a titanium Coriolis mass flow meter: A case of hydrogen embrittlement
    Santos, I. G. R.
    Vacchi, G. S.
    Silva, R.
    Kugelmeier, C. L.
    Magalhaes, D. C. C.
    Campesan, G. R.
    Rovere, C. A. D.
    ENGINEERING FAILURE ANALYSIS, 2020, 115
  • [25] Bunkering of marine fuel using the coriolis mass flow meter (Mfm) system
    Bunkering of marine fuel using the coriolis mass flow meter (Mfm) system, 2021, : 1 - 49
  • [26] A self-validating digital Coriolis mass-flow meter: an overview
    Henry, MP
    Clarke, DW
    Archer, N
    Bowles, J
    Leahy, MJ
    Liu, RP
    Vignos, J
    Zhou, FB
    CONTROL ENGINEERING PRACTICE, 2000, 8 (05) : 487 - 506
  • [27] Compact Micro-Coriolis Mass-Flow Meter with Optical Readout
    Yariesbouei, Mahdieh
    Sanders, Remco G. P.
    Wiegerink, Remco J.
    Lotters, Joost C.
    MICROMACHINES, 2024, 15 (01)
  • [28] Modeling of Coriolis mass flow meter of a general plane-shape pipe
    Guirguis, Samer
    Fan ShangChun
    FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (01) : 40 - 47
  • [30] Coriolis flow meters - the potential for outstanding dynamic performance
    Clark, C
    Cheesewright, R
    MEASUREMENT & CONTROL, 2003, 36 (09): : 275 - +