Calibration of CCD detector after damage

被引:0
|
作者
A. P. Dudka
机构
[1] Russian Academy of Sciences,Shubnikov Institute of Crystallography
来源
Crystallography Reports | 2015年 / 60卷
关键词
Sapphire; Crystallography Report; Reliability Factor; Identical Reflection; Langasite Family;
D O I
暂无
中图分类号
学科分类号
摘要
An Xcalibur X-ray diffractometer with a Sapphire 3 CCD detector (Rigaku Oxford Diffraction) has been calibrated to remove damage effects. Visual proof of the validity of the detector calibration map is obtained for the first time. The calibration has significantly improved the reliability of the structural data on Ba3TaFe3Si2O14 single crystal.
引用
收藏
页码:984 / 985
页数:1
相关论文
共 50 条
  • [21] Calibration of the energy response matrix for X-ray detector CCD236
    Zhu, Y. X.
    Lu, J. B.
    Li, X. B.
    Liu, X. Y.
    Cui, W. W.
    Han, D. W.
    Wang, J.
    Wang, Y. S.
    Zhao, X. F.
    Zhang, S.
    Wang, G. F.
    Chen, Y. P.
    Yu, N.
    Chen, Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (05)
  • [22] THE CFHT CCD DETECTOR
    WALKER, GAH
    JOHNSON, R
    CHRISTIAN, CA
    WADDELL, P
    KORMENDY, J
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 501 : 353 - 358
  • [23] A Relative Radiometric Calibration Method Based on Solar Diffuser Research for a Linear Array CCD Detector
    Xu Heyu
    Zhang Liming
    Li Xin
    Huang Wenxin
    Si Xiaolong
    Xu Weiwei
    Ge Shule
    Zhao Yanhua
    Wang Hao
    ACTA OPTICA SINICA, 2020, 40 (06)
  • [24] The EPIC pn-CCD detector aboard XMM-Newton: status of the background calibration
    Freyberg, MJ
    Briel, UG
    Dennerl, K
    Haberl, F
    Hartner, G
    Pfeffermann, E
    Kendziorra, E
    Kirsch, M
    Lumb, D
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XIII, 2004, 5165 : 112 - 122
  • [25] Influence of heavy ion irradiation damage on silicon charged particle detector calibration
    Zhang, YW
    Whitlow, HJ
    Winzell, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 161 (161): : 297 - 301
  • [26] A Simple Method of Calibration for Multichannel Spectrograph Using Charge-Coupled Device (CCD) as a Detector for Raman Spectroscopy
    Shukla R.P.
    Kumar S.
    Sinha A.K.
    Mallick M.
    Thakur S.
    Sahoo N.K.
    Das N.C.
    Journal of Optics, 2004, 33 (2) : 87 - 107
  • [27] ARGONNE MODULAR CCD DETECTOR.
    Duke, N. E. C.
    Naday, I.
    Westbrook, E. M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C579 - C579
  • [28] Choosing a scientific CCD detector for Spectroscopy
    Gilchrist, JR
    PHOTONICS SPECTRA, 2002, 36 (03) : 83 - +
  • [29] OPTIMUM EVENT RATE FOR A CCD DETECTOR
    HALL, BD
    REINHARD, D
    MONOT, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (03): : 2668 - 2671
  • [30] CCD imaging detector for Smit telescope
    Lu, Wei
    Hongwai/Infrared, 1992, (06): : 18 - 23