OPTIMUM EVENT RATE FOR A CCD DETECTOR

被引:3
|
作者
HALL, BD [1 ]
REINHARD, D [1 ]
MONOT, R [1 ]
机构
[1] ECOLE POLYTECH FED LAUSANNE,INST PHYS EXPTL,CH-1015 LAUSANNE,SWITZERLAND
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1995年 / 66卷 / 03期
关键词
D O I
10.1063/1.1145607
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A simple event-counting technique is considered that can be implemented on detector systems with adjustable exposure times. A single measurement cycle has two steps: exposure and readout. During readout a threshold is used to discriminate against background noise, making it impossible to differentiate between single or multiple events. The actual event rate can be estimated by accumulating the results of repeated measurement cycles, and applying a correction based on the probability for multiple events to occur. By considering the uncertainty in the estimation of the event rate, and assuming a Poisson process, it is shown that optimum exposure requires an average event count per exposure of roughly 1.7. The technique is applied to a high-energy electron-counting system based on a linear CCD photodetector. © 1995 American Institute of Physics.
引用
收藏
页码:2668 / 2671
页数:4
相关论文
共 50 条
  • [1] THE CFHT CCD DETECTOR
    WALKER, GAH
    JOHNSON, R
    CHRISTIAN, CA
    WADDELL, P
    KORMENDY, J
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 501 : 353 - 358
  • [2] CALIBRATION OF THE CCD DETECTOR
    Otwinowski, Zbyszek
    Minor, Wiadek
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 217 - 217
  • [3] AN OPTIMUM GENERALIZED CROSS-SPECTRUM SYMBOL-RATE DETECTOR
    KIM, SH
    SCHOLTZ, RA
    IEEE TRANSACTIONS ON COMMUNICATIONS, 1993, 41 (09) : 1399 - 1411
  • [4] ARGONNE MODULAR CCD DETECTOR.
    Duke, N. E. C.
    Naday, I.
    Westbrook, E. M.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C579 - C579
  • [5] Choosing a scientific CCD detector for Spectroscopy
    Gilchrist, JR
    PHOTONICS SPECTRA, 2002, 36 (03) : 83 - +
  • [6] CCD imaging detector for Smit telescope
    Lu, Wei
    Hongwai/Infrared, 1992, (06): : 18 - 23
  • [7] A CCD-based detector for SPECT
    Nagarkar, VV
    Shestakova, I
    Gaysinskiy, V
    Tipnis, SV
    Singh, B
    Barber, W
    Hasegawa, B
    Entine, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 54 - 58
  • [8] DATA QUALITY AND THE MODERN CCD DETECTOR
    Flippen-Anderson, J.
    Deschamps, J. R.
    George, C.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C260 - C260
  • [9] Which CCD detector is right for you?
    De Goy, S
    Lanzisera, D
    Lopez, K
    Noonan, J
    Rebello, J
    SPECTROSCOPY, 1998, 13 (10) : 36 - 42
  • [10] Calibration of CCD detector after damage
    Dudka, A. P.
    CRYSTALLOGRAPHY REPORTS, 2015, 60 (06) : 984 - 985