Calibration of CCD detector after damage

被引:0
|
作者
A. P. Dudka
机构
[1] Russian Academy of Sciences,Shubnikov Institute of Crystallography
来源
Crystallography Reports | 2015年 / 60卷
关键词
Sapphire; Crystallography Report; Reliability Factor; Identical Reflection; Langasite Family;
D O I
暂无
中图分类号
学科分类号
摘要
An Xcalibur X-ray diffractometer with a Sapphire 3 CCD detector (Rigaku Oxford Diffraction) has been calibrated to remove damage effects. Visual proof of the validity of the detector calibration map is obtained for the first time. The calibration has significantly improved the reliability of the structural data on Ba3TaFe3Si2O14 single crystal.
引用
收藏
页码:984 / 985
页数:1
相关论文
共 50 条
  • [41] The MINOS calibration detector
    Cabrera, A
    Hartnell, J
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2005, 143 : 533 - 533
  • [42] Geometric calibration of CCD array camera
    Kao Neng Wu Li Yu Ho Wu Li, 11 (308-313, 317):
  • [43] GAIN CALIBRATION OF CCD SYSTEMS AT VBO
    PRABHU, TP
    MAYYA, YD
    ANUPAMA, GC
    JOURNAL OF ASTROPHYSICS AND ASTRONOMY, 1992, 13 (01) : 129 - 144
  • [44] CALIBRATION OF THE LICK RED CCD BANDPASSES
    DJORGOVSKI, S
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 1985, 97 (597) : 1119 - 1126
  • [45] Statistical calibration of CCD imaging process
    Tsin, Y
    Ramesh, V
    Kanade, T
    EIGHTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOL I, PROCEEDINGS, 2001, : 480 - 487
  • [46] On DLT method for CCD camera calibration
    Wei, QC
    Zhou, GQ
    Zhu, Q
    Zhang, QH
    ICSP '96 - 1996 3RD INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, PROCEEDINGS, VOLS I AND II, 1996, : 883 - 885
  • [47] A calibration method for navigation cameras' parameters of planetary detector after landing
    Yan Y.
    Peng S.
    Ma Y.
    Zhang S.
    Qi C.
    Wen B.
    Li H.
    Jia Y.
    Liu S.
    Cehui Xuebao/Acta Geodaetica et Cartographica Sinica, 2022, 51 (03): : 437 - 445
  • [48] X-ray CCD calibration for the AXAF CCD imaging spectrometer
    Bautz, M
    Pivovaroff, M
    Baganoff, F
    Isobe, T
    Jones, S
    Kissel, S
    LaMarr, B
    Manning, H
    Prigozhin, G
    Ricker, G
    Nousek, J
    Grant, C
    Nishikida, K
    Scholze, F
    Thornagel, R
    Ulm, G
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 210 - 224
  • [49] How to Calibrate Your CCD in the Dark? a Precise CCD Calibration Method
    Golebiewska, Urszula P.
    Yanagisawa, Chiaki
    BIOPHYSICAL JOURNAL, 2017, 112 (03) : 296A - 296A
  • [50] X-ray CCD calibration for the AXAF CCD imaging spectrometer
    Bautz, M
    Kissel, S
    Prigozhin, G
    Jones, S
    Isobe, T
    Manning, H
    Pivovaroff, M
    Ricker, G
    Woo, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 : 170 - 181