Clinical evaluation of a novel subcutaneous lactate monitor

被引:0
|
作者
Nitsan Dror
John Weidling
Sean White
Francesca Ortenzio
Samir Shreim
Mark T. Keating
Hoang Pham
Shlomit Radom-Aizik
Elliot Botvinick
机构
[1] University of California Irvine,Pediatric Exercise and Genomics Research Center, Department of Pediatrics, School of Medicine
[2] Child Health and Sports Center,Pediatric Department, Meir Medical Center
[3] Sackler School of Medicine,Department of Dermatology
[4] Tel Aviv University,Edwards Lifesciences Center for Advanced Cardiovascular Technology
[5] Beckman Laser Institute and Medical Clinic,undefined
[6] University of California Irvine,undefined
[7] University of California Irvine Health,undefined
[8] University of California Irvine,undefined
关键词
Continuous lactate monitor; Lactate; Lactic acid; Real-time monitoring; Exercise physiology; Optode;
D O I
暂无
中图分类号
学科分类号
摘要
Lactate levels are commonly used as an indirect measure to assess metabolic stress in clinical conditions like sepsis. Dynamic lactate measurements are recommended to assess and guide treatment in patients with shock and other critical care conditions. A minimally invasive, continuous lactate monitor has potential to improve clinical decisions and patient care. The purpose of the study was to evaluate continuous lactate measurements of a novel enzymatic Continuous Lactate Monitor (CLM) developed in our laboratory. Lactate levels were monitored during incremental cycling exercise challenges as a tool for hyperlactatemia. Six healthy individuals 18–45 y/o (4 males, 2 females) participated in the study. CLM devices were inserted subcutaneously in the postero-lateral trunk below the renal angle, one hour before the exercise challenge. Each exercise challenge consisted of a 3 to 12-min warm up period, followed by up to 7, 4-min incremental workload bouts separated by rest intervals. Continuous lactate measurements obtained from CLM were compared with commercial lactate analyzer (Abbott iSTAT) measurements of venous blood (plasma) drawn from the antecubital vein. Blood was drawn at up to 25 time points spanning the duration of before exercise, during exercise, and up to 120 min post exercise. Area under the curve (AUC), and delay time were calculated to compare the CLM readings with plasma lactate concentration. Average plasma lactate concentration increased from 1.02 to 16.21 mM. Ratio of AUC derived from CLM to plasma lactate was 1.025 (0.990–1.058). Average dynamic delay time of CLM to venous plasma lactate was 5.22 min (2.87–10.35). Insertion sites examined 48 h after CLM removal did not show signs of side effects and none required medical attention upon examination. The newly developed CLM has shown to be a promising tool to continuously measure lactate concentration in a minimally invasive fashion. Results indicate the CLM can provide needed trends in lactate over time. Such a device may be used in the future to improve treatment in clinical conditions such as sepsis.
引用
收藏
页码:537 / 543
页数:6
相关论文
共 50 条
  • [1] Clinical evaluation of a novel subcutaneous lactate monitor
    Dror, Nitsan
    Weidling, John
    White, Sean
    Ortenzio, Francesca
    Shreim, Samir
    Keating, Mark T.
    Pham, Hoang
    Radom-Aizik, Shlomit
    Botvinick, Elliot
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (02) : 537 - 543
  • [2] Exercise As A Tool For Evaluation Of A Novel Subcutaneous Lactate Monitor
    Dror, Nitsan
    Weidling, John
    Radom-Aizik, Shlomit
    White, Sean
    Ortenzio, Francesca
    Botvinick, Elliot
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 36 - 36
  • [3] Clinical evaluation of a novel respiratory rate monitor
    Lee, Peter J.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (02) : 175 - 183
  • [4] Clinical evaluation of a novel respiratory rate monitor
    Peter J. Lee
    [J]. Journal of Clinical Monitoring and Computing, 2016, 30 : 175 - 183
  • [5] Clinical Evaluation of Subcutaneous Lactate Measurement in Patients after Major Cardiac Surgery
    Ellmerer, Martin
    Haluzik, Martin
    Blaha, Jan
    Kremen, Jaromir
    Svacina, Stepan
    Plasnik, Andreas
    Ikeoka, Dimas
    Bodenlenz, Manfred
    Schaupp, Lukas
    Plank, Johannes
    Pieber, Thomas R.
    [J]. INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2009, 2009
  • [6] A novel continuous subcutaneous lactate monitoring system
    Poscia, A
    Messeri, D
    Moscone, D
    Ricci, F
    Valgimigli, F
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (11): : 2244 - 2250
  • [7] Evaluation of the Lactate Plus monitor for plasma lactate concentration measurement in dogs
    Nye, Carolyn J.
    Musulin, Sarah E.
    Hanel, Rita M.
    Mariani, Christopher L.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2017, 27 (01) : 66 - 70
  • [8] Clinical evaluation of a novel ultrasound-based bladder volume monitor
    Kristiansen, NK
    Nygaard, H
    Djurhuus, JC
    [J]. SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2005, 39 (04): : 321 - 328
  • [9] Monitor for lactate in perspiration
    Ting-Ting Luo
    Zhong-Hai Sun
    Chu-Xin Li
    Jin-Lian Feng
    Zhao-Xiu Xiao
    Wei-Dong Li
    [J]. The Journal of Physiological Sciences, 2021, 71
  • [10] Monitor for lactate in perspiration
    Luo, Ting-Ting
    Sun, Zhong-Hai
    Li, Chu-Xin
    Feng, Jin-Lian
    Xiao, Zhao-Xiu
    Li, Wei-Dong
    [J]. JOURNAL OF PHYSIOLOGICAL SCIENCES, 2021, 71 (01):