Evaluation of the Lactate Plus monitor for plasma lactate concentration measurement in dogs

被引:11
|
作者
Nye, Carolyn J. [1 ]
Musulin, Sarah E. [2 ]
Hanel, Rita M. [2 ]
Mariani, Christopher L. [1 ,2 ]
机构
[1] North Carolina State Univ, Coll Vet Med, Comparat Neuroimmunol & Neurooncol Lab, Raleigh, NC 27607 USA
[2] North Carolina State Univ, Coll Vet Med, Dept Clin Sci, 1060 William Moore Dr, Raleigh, NC 27607 USA
关键词
canine; metabolic acidosis; perfusion; point of care; shock; validation; BLOOD LACTATE; SEVERE SEPSIS; GLUCOSE; ASSOCIATION; ANALYZER; GAS;
D O I
10.1111/vec.12557
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo compare the Lactate Plus handheld monitor to a reference blood gas analyzer for determining plasma lactate concentrations in canine whole blood. DesignProspective observational study. SettingUniversity teaching hospital. AnimalsNinety-four dogs hospitalized or admitted through the emergency service provided 125 blood samples. Only dogs that required a venous or arterial blood gas evaluation as a part of their diagnostic assessment or ongoing management were included. InterventionsNone. Measurements and Main ResultsCanine whole blood samples were assayed for plasma lactate concentration with a reference blood gas analyzer and the Lactate Plus monitor. Correlation and Bland-Altman analyses were used to compare results between the 2 methods. A subset of blood samples was repeatedly analyzed with the Lactate Plus to assess monitor precision. Plasma lactate measurements from the Lactate Plus monitor showed excellent correlation with those from the reference analyzer ( = 0.98, P < 0.0001). Bland-Altman analysis revealed a small bias (0.1296). Agreement between the 2 methods was less consistent for lactate concentrations >5 mmol/L. The coefficient of variation ranged from 0-26.2% (median, 3.7%) and was <15% for 50/53 samples. ConclusionsThe Lactate Plus provides a fast and affordable method to measure plasma lactate concentration in dogs. Results showed excellent agreement with the reference analyzer and precision of the instrument was acceptable.
引用
收藏
页码:66 / 70
页数:5
相关论文
共 50 条
  • [1] Measurement of plasma lactate concentration with accusport
    Lindner, A
    [J]. EQUINE VETERINARY JOURNAL, 1996, 28 (05) : 403 - 405
  • [2] Evaluation of the Accutrend for lactate measurement in dogs
    Stevenson, Connie K.
    Kidney, Beverly A.
    Duke, Tanya
    Snead, Elisabeth C. R.
    Jackson, Marion L.
    [J]. VETERINARY CLINICAL PATHOLOGY, 2007, 36 (03) : 261 - 266
  • [3] Evaluation of a portable lactate analyzer (Lactate Scout) in dogs
    Ferasin, Luca
    Dodkin, Stephen J.
    Amodio, Annarita
    Murray, Jane K.
    Papasouliotis, Kostas
    [J]. VETERINARY CLINICAL PATHOLOGY, 2007, 36 (01) : 36 - 39
  • [4] Influence of lactate infusion solutions on the plasma lactate concentration
    Raum, M
    Rixen, D
    Linker, R
    Gregor, S
    Holzgraefe, B
    Neugebauer, E
    [J]. ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2002, 37 (06): : 356 - 358
  • [5] Evaluation of cerebrospinal fluid lactate and plasma lactate concentrations in anesthetized dogs with and without intracranial disease
    Caines, Deanne
    Sinclair, Melissa
    Wood, Darren
    Valverde, Alexander
    Dyson, Doris
    Gaitero, Luis
    Nykamp, Stephanie
    [J]. CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2013, 77 (04): : 297 - 302
  • [6] Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus
    Tanner, Rebecca K.
    Fuller, Kate L.
    Ross, Megan L. R.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 109 (03) : 551 - 559
  • [7] Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus
    Rebecca K. Tanner
    Kate L. Fuller
    Megan L. R. Ross
    [J]. European Journal of Applied Physiology, 2010, 109 : 551 - 559
  • [8] Blood lactate concentration in diabetic dogs
    Claus, Poliana
    Gimenes, Andre M.
    Castro, Jacqueline R.
    Mantovani, Matheus M.
    Kanayama, Khadine K.
    Simoes, Denise M. N.
    Schwartz, Denise S.
    [J]. CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2017, 58 (08): : 817 - 822
  • [9] Plasma Lactate Concentration as a Prognostic Biomarker in Dogs With Gastric Dilation and Volvulus
    Mooney, Erin
    Raw, Cameron
    Hughes, Dez
    [J]. TOPICS IN COMPANION ANIMAL MEDICINE, 2014, 29 (03) : 71 - 76
  • [10] Effect of Hydroxocobalamin on Measurement of Plasma Lactate Concentration: An In Vitro Study
    Laforge, M.
    Borron, S. W.
    Baud, F. J.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2008, 52 (04) : S136 - S136