Clinical evaluation of a novel subcutaneous lactate monitor

被引:5
|
作者
Dror, Nitsan [1 ,2 ]
Weidling, John [3 ,4 ]
White, Sean [3 ,4 ]
Ortenzio, Francesca [5 ]
Shreim, Samir [3 ,4 ]
Keating, Mark T. [3 ,4 ]
Pham, Hoang [1 ]
Radom-Aizik, Shlomit [1 ]
Botvinick, Elliot [3 ,4 ,6 ]
机构
[1] Univ Calif Irvine, Dept Pediat, Sch Med, Pediat Exercise & Genom Res Ctr, Irvine, CA 92717 USA
[2] Tel Aviv Univ, Sackler Sch Med, Child Hlth & Sports Ctr, Pediat Dept,Meir Med Ctr, Tel Aviv, Israel
[3] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92717 USA
[4] Univ Calif Irvine, Med Clin, Irvine, CA 92717 USA
[5] Univ Calif Irvine Hlth, Dept Dermatol, Irvine, CA USA
[6] Univ Calif Irvine, Edwards Lifesci Ctr Adv Cardiovasc Technol, Irvine, CA 92717 USA
关键词
Continuous lactate monitor; Lactate; Lactic acid; Real-time monitoring; Exercise physiology; Optode;
D O I
10.1007/s10877-021-00685-1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Lactate levels are commonly used as an indirect measure to assess metabolic stress in clinical conditions like sepsis. Dynamic lactate measurements are recommended to assess and guide treatment in patients with shock and other critical care conditions. A minimally invasive, continuous lactate monitor has potential to improve clinical decisions and patient care. The purpose of the study was to evaluate continuous lactate measurements of a novel enzymatic Continuous Lactate Monitor (CLM) developed in our laboratory. Lactate levels were monitored during incremental cycling exercise challenges as a tool for hyperlactatemia. Six healthy individuals 18-45 y/o (4 males, 2 females) participated in the study. CLM devices were inserted subcutaneously in the postero-lateral trunk below the renal angle, one hour before the exercise challenge. Each exercise challenge consisted of a 3 to 12-min warm up period, followed by up to 7, 4-min incremental workload bouts separated by rest intervals. Continuous lactate measurements obtained from CLM were compared with commercial lactate analyzer (Abbott iSTAT) measurements of venous blood (plasma) drawn from the antecubital vein. Blood was drawn at up to 25 time points spanning the duration of before exercise, during exercise, and up to 120 min post exercise. Area under the curve (AUC), and delay time were calculated to compare the CLM readings with plasma lactate concentration. Average plasma lactate concentration increased from 1.02 to 16.21 mM. Ratio of AUC derived from CLM to plasma lactate was 1.025 (0.990-1.058). Average dynamic delay time of CLM to venous plasma lactate was 5.22 min (2.87-10.35). Insertion sites examined 48 h after CLM removal did not show signs of side effects and none required medical attention upon examination. The newly developed CLM has shown to be a promising tool to continuously measure lactate concentration in a minimally invasive fashion. Results indicate the CLM can provide needed trends in lactate over time. Such a device may be used in the future to improve treatment in clinical conditions such as sepsis.
引用
收藏
页码:537 / 543
页数:7
相关论文
共 50 条
  • [1] Clinical evaluation of a novel subcutaneous lactate monitor
    Nitsan Dror
    John Weidling
    Sean White
    Francesca Ortenzio
    Samir Shreim
    Mark T. Keating
    Hoang Pham
    Shlomit Radom-Aizik
    Elliot Botvinick
    [J]. Journal of Clinical Monitoring and Computing, 2022, 36 : 537 - 543
  • [2] Exercise As A Tool For Evaluation Of A Novel Subcutaneous Lactate Monitor
    Dror, Nitsan
    Weidling, John
    Radom-Aizik, Shlomit
    White, Sean
    Ortenzio, Francesca
    Botvinick, Elliot
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 36 - 36
  • [3] Clinical evaluation of a novel respiratory rate monitor
    Lee, Peter J.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (02) : 175 - 183
  • [4] Clinical evaluation of a novel respiratory rate monitor
    Peter J. Lee
    [J]. Journal of Clinical Monitoring and Computing, 2016, 30 : 175 - 183
  • [5] Clinical Evaluation of Subcutaneous Lactate Measurement in Patients after Major Cardiac Surgery
    Ellmerer, Martin
    Haluzik, Martin
    Blaha, Jan
    Kremen, Jaromir
    Svacina, Stepan
    Plasnik, Andreas
    Ikeoka, Dimas
    Bodenlenz, Manfred
    Schaupp, Lukas
    Plank, Johannes
    Pieber, Thomas R.
    [J]. INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2009, 2009
  • [6] A novel continuous subcutaneous lactate monitoring system
    Poscia, A
    Messeri, D
    Moscone, D
    Ricci, F
    Valgimigli, F
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (11): : 2244 - 2250
  • [7] Evaluation of the Lactate Plus monitor for plasma lactate concentration measurement in dogs
    Nye, Carolyn J.
    Musulin, Sarah E.
    Hanel, Rita M.
    Mariani, Christopher L.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2017, 27 (01) : 66 - 70
  • [8] Clinical evaluation of a novel ultrasound-based bladder volume monitor
    Kristiansen, NK
    Nygaard, H
    Djurhuus, JC
    [J]. SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2005, 39 (04): : 321 - 328
  • [9] Monitor for lactate in perspiration
    Ting-Ting Luo
    Zhong-Hai Sun
    Chu-Xin Li
    Jin-Lian Feng
    Zhao-Xiu Xiao
    Wei-Dong Li
    [J]. The Journal of Physiological Sciences, 2021, 71
  • [10] Monitor for lactate in perspiration
    Luo, Ting-Ting
    Sun, Zhong-Hai
    Li, Chu-Xin
    Feng, Jin-Lian
    Xiao, Zhao-Xiu
    Li, Wei-Dong
    [J]. JOURNAL OF PHYSIOLOGICAL SCIENCES, 2021, 71 (01):