Clinical evaluation of a novel ultrasound-based bladder volume monitor

被引:16
|
作者
Kristiansen, NK
Nygaard, H
Djurhuus, JC
机构
[1] Aarhus Univ Hosp & Univ, Inst Clin Med, DK-8200 Aarhus, Denmark
[2] Univ Coll Aarhus, Dept Elect & Informat Technol, Aarhus, Denmark
[3] Aarhus Univ Hosp, Skejby Sygehus, Dept Urol K, Urodynam Lab, DK-8000 Aarhus, Denmark
来源
关键词
bladder volume monitor; cystometry; ultrasonography; urinary bladder volume;
D O I
10.1080/00365590510031165
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective. Bladder volume monitors may be useful for surveillance of bladder volume and urine production in urologic patients. Therefore, we designed an ultrasonic bladder volume monitor and evaluated it in vitro using phantoms and in vivo in one male volunteer. The purpose of this study was to perform a more thorough in vivo evaluation of our monitor in urologic patients to investigate biological effects and variance over a wide range of bladder volumes. Material and methods. Thirty urologic patients of either gender were examined using the bladder volume monitor, which is based on seven phased array ultrasonic transducers arranged in a circular pattern to optimize detection of the bladder walls. The monitor was set up to record bladder volume every 30 s during two sequential cystometries with infusion rates of 30 and 60 ml/ min. The measured volumes were analyzed using regression analysis to determine volume increments ( slopes), offset volume ( intercept) and correlation ( Pearson's correlation coefficient). Results. In the male patients, the median correlation coefficient between the infused and measured volumes was 0.97 and the slope was 0.68 ml/ ml, thus warranting a correction factor of approximate to 1.47 with no general volume offset. In the female patients, small bladders were generally outside the field of view of the monitor. Consequently, the correlation coefficients and slopes were 0.834 ( median) and 0.43 ( mean), respectively, whereas volume offsets were generally negative. Conclusions. For examinations in male patients, the performance of the bladder volume monitor was adequate. However, for examinations in female patients, a minor redesign of the transducer unit is necessary to insure proper operation.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 50 条
  • [1] Design and evaluation of an ultrasound-based bladder volume monitor
    Kristiansen, NK
    Djurhuus, JC
    Nygaard, H
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (06) : 762 - 769
  • [2] Design and evaluation of an ultrasound-based bladder volume monitor
    N. K. Kristiansen
    J. C. Djurhuus
    H. Nygaard
    [J]. Medical and Biological Engineering and Computing, 2004, 42 : 762 - 769
  • [3] BLADDER VOLUME ESTIMATION IN THE ELDERLY USING A PORTABLE ULTRASOUND-BASED MEASUREMENT DEVICE
    TOPPER, AK
    HOLLIDAY, PJ
    FERNIE, GR
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1993, 17 (03) : 99 - 103
  • [4] Ultrasound-based sensors to monitor physiological motion
    Madore, Bruno
    Preiswerk, Frank
    Bredfeldt, Jeremy S.
    Zong, Shenyan
    Cheng, Cheng-Chieh
    [J]. MEDICAL PHYSICS, 2021, 48 (07) : 3614 - 3622
  • [5] Evaluation of Ultrasound-Based Sensor to Monitor Respiratory and Nonrespiratory Movement and Timing in Infants
    Heldt, Gregory P.
    Ward, Raymond J., III
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (03) : 619 - 629
  • [6] Improving ultrasound-based prostate volume estimation
    Saro Aprikian
    Murilo Luz
    Fadi Brimo
    Eleonora Scarlata
    Lucie Hamel
    Fabio L. Cury
    Simon Tanguay
    Armen G. Aprikian
    Wassim Kassouf
    Simone Chevalier
    [J]. BMC Urology, 19
  • [7] Improving ultrasound-based prostate volume estimation
    Aprikian, Saro
    Luz, Murilo
    Brimo, Fadi
    Scarlata, Eleonora
    Hamel, Lucie
    Cury, Fabio L.
    Tanguay, Simon
    Aprikian, Armen G.
    Kassouf, Wassim
    Chevalier, Simone
    [J]. BMC UROLOGY, 2019, 19 (1) : 68
  • [8] Design and Evaluation of a New Bladder Volume Monitor
    Wang, Jianhuo
    Hou, Chunlin
    Zheng, Xianyou
    Zhang, Wei
    Chen, Aimin
    Xu, Zhen
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (11): : 1944 - 1947
  • [9] The Role of Ultrasound-Based Monitoring of Bladder Volume in Patients with Prostate Cancer during CyberKnife Stereotactic Radiosurgery
    Bodusz, Dawid
    Brajczewska-Bello, Joanna
    Rutkowski, Tomasz
    Kolosza, Zofia
    Cortez, Alexander Jorge
    Szymala-Cortez, Magdalena
    Leszczyński, Wojciech
    Wydmański, Jerzy
    [J]. Applied Sciences (Switzerland), 2024, 14 (19):
  • [10] Doppler ultrasound-based noninvasive biomarkers in hidradenitis suppurativa: evaluation of analytical and clinical validity
    Grand, D.
    Frew, J. W.
    Navrazhina, K.
    Krueger, J. G.
    [J]. BRITISH JOURNAL OF DERMATOLOGY, 2021, 184 (04) : 688 - 696