Design and evaluation of an ultrasound-based bladder volume monitor

被引:0
|
作者
N. K. Kristiansen
J. C. Djurhuus
H. Nygaard
机构
[1] Aarhus University Hospital,Clinical Institute
[2] Aarhus University Hospital,Department of Cardiothoracic & Vascular Surgery
[3] University College of Aarhus,Department of Electronics & Information Technology
关键词
Bladder scanner; Ultrasound; Bladder volume;
D O I
暂无
中图分类号
学科分类号
摘要
Ultrasonic bladder volume monitors have successfully been used in the diagnosis and treatment of various urological disorders. Ultrasonic bladder monitors have been developed but they have either been too bulky or too simple and inaccurate. A new, wearable ultrasonic bladder volume monitor has been designed for urological patients. The instrument consists of seven phased-array ultrasonic transducers ergonomically arranged in a circular pattern to optimise detection of the bladder walls perpendicular to the abdominal wall. A Bluetooth radio link was used to transmit data to a laptop computer, where the main signal processing was performed. After detection of bladder surface points, a three-dimensional convex hull representing the bladder was generated, and the volume was estimated. Accuracy, precision, drift over time, temperature dependency and dynamic performance were evaluated using ultrasound phantoms. Furthermore, the system was tested on one volunteer using magnetic resonance imaging (MRI) as reference. The apparatus showed no significant drift, systematic error or temperature effects. Percentage error during static volume measurements had a 95% central prediction interval of ±7.5% and mean absolute percentage error of 2.9%. The dynamic performance analysis showed linearity in the analysed volume interval. The in vivo study showed a high degree of correlation (R2=0.99) between the volume measured using MRI and that measured with the apparatus.
引用
收藏
页码:762 / 769
页数:7
相关论文
共 50 条
  • [1] Design and evaluation of an ultrasound-based bladder volume monitor
    Kristiansen, NK
    Djurhuus, JC
    Nygaard, H
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (06) : 762 - 769
  • [2] Clinical evaluation of a novel ultrasound-based bladder volume monitor
    Kristiansen, NK
    Nygaard, H
    Djurhuus, JC
    [J]. SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2005, 39 (04): : 321 - 328
  • [3] Design and Evaluation of a New Bladder Volume Monitor
    Wang, Jianhuo
    Hou, Chunlin
    Zheng, Xianyou
    Zhang, Wei
    Chen, Aimin
    Xu, Zhen
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (11): : 1944 - 1947
  • [4] BLADDER VOLUME ESTIMATION IN THE ELDERLY USING A PORTABLE ULTRASOUND-BASED MEASUREMENT DEVICE
    TOPPER, AK
    HOLLIDAY, PJ
    FERNIE, GR
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1993, 17 (03) : 99 - 103
  • [5] Ultrasound-based sensors to monitor physiological motion
    Madore, Bruno
    Preiswerk, Frank
    Bredfeldt, Jeremy S.
    Zong, Shenyan
    Cheng, Cheng-Chieh
    [J]. MEDICAL PHYSICS, 2021, 48 (07) : 3614 - 3622
  • [6] Evaluation of Ultrasound-Based Sensor to Monitor Respiratory and Nonrespiratory Movement and Timing in Infants
    Heldt, Gregory P.
    Ward, Raymond J., III
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (03) : 619 - 629
  • [7] Improving ultrasound-based prostate volume estimation
    Saro Aprikian
    Murilo Luz
    Fadi Brimo
    Eleonora Scarlata
    Lucie Hamel
    Fabio L. Cury
    Simon Tanguay
    Armen G. Aprikian
    Wassim Kassouf
    Simone Chevalier
    [J]. BMC Urology, 19
  • [8] Improving ultrasound-based prostate volume estimation
    Aprikian, Saro
    Luz, Murilo
    Brimo, Fadi
    Scarlata, Eleonora
    Hamel, Lucie
    Cury, Fabio L.
    Tanguay, Simon
    Aprikian, Armen G.
    Kassouf, Wassim
    Chevalier, Simone
    [J]. BMC UROLOGY, 2019, 19 (1) : 68
  • [9] Design and Evaluation of Haptic Guidance in Ultrasound-Based Needle-Insertion Procedures
    Raitor, Michael
    Nunez, Cara M.
    Stolka, Philipp J.
    Okamura, Allison M.
    Culbertson, Heather
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (01) : 26 - 35
  • [10] The Role of Ultrasound-Based Monitoring of Bladder Volume in Patients with Prostate Cancer during CyberKnife Stereotactic Radiosurgery
    Bodusz, Dawid
    Brajczewska-Bello, Joanna
    Rutkowski, Tomasz
    Kolosza, Zofia
    Cortez, Alexander Jorge
    Szymala-Cortez, Magdalena
    Leszczyński, Wojciech
    Wydmański, Jerzy
    [J]. Applied Sciences (Switzerland), 2024, 14 (19):