Improving ultrasound-based prostate volume estimation

被引:16
|
作者
Aprikian, Saro [1 ]
Luz, Murilo [1 ,2 ,3 ]
Brimo, Fadi [1 ,3 ,4 ]
Scarlata, Eleonora [1 ]
Hamel, Lucie [1 ]
Cury, Fabio L. [1 ,3 ,5 ]
Tanguay, Simon [1 ,2 ,3 ,6 ]
Aprikian, Armen G. [1 ,2 ,3 ,6 ]
Kassouf, Wassim [1 ,2 ,3 ,6 ]
Chevalier, Simone [1 ,2 ,3 ,6 ,7 ]
机构
[1] MUHC, RI, Canc Res Program, Urol Oncol Res Grp, Glen Campus,E M2-2210,1001 Blvd Decarie, Montreal, PQ H4A 3J1, Canada
[2] MUHC, Dept Surg, Urol Div, Montreal, PQ, Canada
[3] McGill Univ, Montreal, PQ, Canada
[4] MUHC, Dept Pathol, Montreal, PQ, Canada
[5] MUHC, Dept Radiat Oncol, Montreal, PQ, Canada
[6] MUHC, Dept Oncol, Montreal, PQ, Canada
[7] MUHC, Dept Med, Montreal, PQ, Canada
关键词
Prostate volume; Trans-rectal ultrasound; Ellipsoid; Bullet; Formula; Coefficient; TRANSRECTAL ULTRASOUND;
D O I
10.1186/s12894-019-0492-2
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
BackgroundTo define a new coefficient to be used in the formula (Volume=L x H x W x Coefficient) that better estimates prostate volume using dimensions of fresh prostates from patients who had transrectal ultrasound (TRUS) imaging prior to prostatectomy.MethodsThe prostate was obtained from 153 patients, weighed and measured to obtain length (L), height (H), and width (W). The density was determined by water displacement to calculate volume. TRUS data were retrieved from patient charts. Linear regression analyses were performed to compare various prostate volume formulas, including the commonly used ellipsoid formula and newly introduced bullet-shaped formula.ResultsBy relating measured prostate volumes from fresh prostates to TRUS-estimated prostate volumes, 0.66 was the best fitting coefficient in the (L x H x W x Coefficient) equation. This newfound coefficient combined with outlier removal yielded a linear equation with an R-2 of 0.64, compared to 0.55 and 0.60, for the ellipsoid and bullet, respectively. By comparing each of the measured vs. estimated dimensions, we observed that the mean prostate height and length were overestimated by 11.1 and 10.8% using ultrasound (p<0.05), respectively, while the mean width was similar (p>0.05). Overall, the ellipsoid formula underestimates prostate volumes by 18%, compared to an overestimation of 4.6 and 5.7% for the bullet formula and the formula using our coefficient, respectively.ConclusionsThis study defines, for the first time, a coefficient based on freshly resected prostates as a reference to estimate volumes by imaging. Our findings support a bullet rather than an ellipsoid prostate shape. Moreover, substituting the coefficient commonly used in the ellipsoid formula by our calculated coefficient in the equation estimating prostate volume by TRUS, provides a more accurate value of the true prostate volume.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Improving ultrasound-based prostate volume estimation
    Saro Aprikian
    Murilo Luz
    Fadi Brimo
    Eleonora Scarlata
    Lucie Hamel
    Fabio L. Cury
    Simon Tanguay
    Armen G. Aprikian
    Wassim Kassouf
    Simone Chevalier
    [J]. BMC Urology, 19
  • [2] Bladder volume estimation in the elderly using a portable ultrasound-based measurement device
    Topper, A.K.
    Holliday, P.J.
    Fernie, G.R.
    [J]. Journal of Medical Engineering and Technology, 1993, 17 (03): : 99 - 103
  • [3] BLADDER VOLUME ESTIMATION IN THE ELDERLY USING A PORTABLE ULTRASOUND-BASED MEASUREMENT DEVICE
    TOPPER, AK
    HOLLIDAY, PJ
    FERNIE, GR
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1993, 17 (03) : 99 - 103
  • [4] Ultrasound-based robot position estimation
    Wehn, HW
    Belanger, PR
    [J]. IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1997, 13 (05): : 682 - 692
  • [5] Ultrasound-Based Target Volume Definition in a Patient with Prostate Carcinoma and bilateral Hip Replacement
    Boda-Heggemann, J.
    Haneder, S.
    Sihono, D. S.
    Mai, S. K.
    Kegel, S.
    Wertz, H.
    Heitmann, S.
    Zimmermann, A.
    Lohr, F.
    Wenz, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 : 70 - 70
  • [6] Improving the accuracy of ultrasound-based localisation systems
    Hubert Piontek
    Matthias Seyffer
    Jörg Kaiser
    [J]. Personal and Ubiquitous Computing, 2007, 11 : 439 - 449
  • [7] Improving the accuracy of ultrasound-based localisation systems
    Piontek, Hubert
    Seyffer, Matthias
    Kaiser, Joerg
    [J]. PERSONAL AND UBIQUITOUS COMPUTING, 2007, 11 (06) : 439 - 449
  • [8] Experience of ultrasound-based daily prostate localization
    Chandra, A
    Dong, L
    Huang, E
    Kuban, DA
    O'Neill, L
    Rosen, I
    Pollack, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02): : 436 - 447
  • [9] Improving the accuracy of ultrasound-based localisation systems
    Piontek, H
    Seyffer, M
    Kaiser, J
    [J]. LOCATION- AND CONTEXT-AWARENESS, PROCEEDINGS, 2005, 3479 : 132 - 143
  • [10] A comparison of preplan MRI and preplan CT-based prostate volume with intraoperative ultrasound-based prostate volume in real-time permanent brachytherapy
    Park, Hyeli
    Kim, Ja Young
    Lee, Bo Mi
    Chang, Sei Kyung
    Ko, Seung Young
    Kim, Sung Jun
    Park, Dong Soo
    Shin, Hyun Soo
    [J]. RADIATION ONCOLOGY JOURNAL, 2011, 29 (03): : 199 - 205