Effect of thyroid shielding during mammography: measurements on phantom and patient as well as estimation with Monte Carlo simulation

被引:6
|
作者
Pyka M. [1 ]
Eschle P. [2 ]
Sommer C. [2 ]
Weyland M.S. [2 ]
Kubik R. [1 ]
Scheidegger S. [2 ]
机构
[1] Department of Medical Services, Institute of Radiology, Kantonsspital Baden, Baden
[2] Zurich University of Applied Science, ZHAW School of Engineering, Winterthur
关键词
Backscatter; Mammography; Monte Carlo simulation; Radiation-induced cancer; Thyroid protection;
D O I
10.1186/s41747-018-0042-9
中图分类号
学科分类号
摘要
Background: During mammography, the thyroid is exposed to scattered radiation from breast tissue and the device. This may increase the risk of radiation induced thyroid cancer. Methods: We investigated the scatter radiation exposition of the thyroid and the effect of a tailored thyroid protection in phantom and patient as well as by using Monte Carlo simulation (MCS). The protective effect of a modified thyroid protection, the relevance of the protective effect and acceptance by patients have been investigated. Results: Phantom and patient measurements provided higher values for the surface dose at thyroid position than expected from MCS (phantom 0.32 mGy; patients 0.38 mGy; MCS 0.16 mGy). Phantom measurements indicated scatter contributions from both breast tissue and collimator/tube system. The value found in our patient study is within the range of the literature (0.22–0.39 mGy). The thyroid protection significantly reduced the surface dose but the dose (0.016 mGy) was higher than that expected from the lead equivalent value. However, the impact of the collar to the effective dose was small (< 4%). The collar was not visible on mammograms. Conclusions: Scatter from the collimator/tube system contributed with 50% to the thyroid dose. Due to the relative small fraction of dose deposited in the thyroid when compared to the mean glandular dose to the breast, a collar is not mandatory in general. Not being associated with the risk of obscuring parts of mammograms, such a collar may be used for young women considering their higher radio sensitivity. © 2018, The Author(s).
引用
收藏
相关论文
共 50 条
  • [1] A Comparative Analysis of Metal Shielding for Mammography Using Monte Carlo Simulation
    Kim, Jang Oh
    Kwon, Da-Eun
    Han, Dong-Hee
    Jung, Kyung-Hwan
    Min, Byung In
    Baek, Cheol Ha
    Lee, Chang-Lae
    [J]. JOURNAL OF MAGNETICS, 2021, 26 (04) : 463 - 466
  • [2] Fast Monte Carlo simulation on a voxelized human phantom deformed to a patient
    Bueno, G.
    Deniz, O.
    Carrascosa, C. B.
    Delgado, J. M.
    Brualla, L.
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5162 - 5174
  • [3] VALIDATION OF MONTE CARLO SIMULATION OF A THYROID UPTAKE SYSTEM USING VARIOUS SOURCES AND A SLAB PHANTOM
    Scarboro, Sarah
    Hertel, Nolan
    Burgett, Eric
    Howell, Rebecca
    Ansari, Armin
    [J]. NUCLEAR TECHNOLOGY, 2009, 168 (01) : 169 - 172
  • [4] Monte-Carlo simulation of uncertainty in the estimation of 125I in the thyroid
    Bhati, S.
    Patni, H. K.
    [J]. RADIATION PROTECTION DOSIMETRY, 2009, 136 (01) : 23 - 29
  • [5] A flexible Monte Carlo tool for patient or phantom specific calculations: comparison with preliminary validation measurements
    Davidson, S.
    Cui, J.
    Followill, D.
    Ibbott, G.
    Deasy, J.
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [6] An Investigation on Shielding Effect of Bismuth on Lung Ct Scan Using Monte Carlo Simulation
    Tekin, Huseyin Ozan
    Manici, Tugba
    Singh, Vishwanath P.
    [J]. JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2016, 19 (04): : 617 - 622
  • [7] Influence of measurement geometry on the estimate of I-131 activity in the thyroid: Monte Carlo simulation of a detector and a phantom
    Ulanovsky, AV
    Minenko, VF
    Korneev, SV
    [J]. HEALTH PHYSICS, 1997, 72 (01): : 34 - 41
  • [8] Mobile shielding evaluation on the fetal dose during a breast radiotherapy using Monte Carlo simulation
    Catusso, Leonardo
    Santos, William S.
    da Silva, Rogerio M., V
    Valenca, Joao V. B.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 24 - 32
  • [9] Estimation of the cable effect in megavoltage photon beam by measurement and Monte Carlo simulation
    Yamauchi, Ryohei
    Igari, Mitsunobu
    Kasai, Yuya
    Hariu, Masatsugu
    Suda, Yuhi
    Kawachi, Toru
    Katayose, Tetsurou
    Mizuno, Norifumi
    Miyasaka, Ryohei
    Saitoh, Hidetoshi
    [J]. MEDICAL PHYSICS, 2020, 47 (10) : 5324 - 5332
  • [10] Dual-energy contrast-enhanced digital mammography: Glandular dose estimation using a Monte Carlo code and voxel phantom
    Tzamicha, E.
    Yakoumakis, E.
    Tsalafoutas, I. A.
    Dimitriadis, A.
    Georgiou, E.
    Tsapaki, V.
    Chalazonitis, A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 785 - 791