Estimation of the cable effect in megavoltage photon beam by measurement and Monte Carlo simulation

被引:1
|
作者
Yamauchi, Ryohei [1 ,2 ]
Igari, Mitsunobu [3 ]
Kasai, Yuya [4 ]
Hariu, Masatsugu [5 ]
Suda, Yuhi [2 ,6 ]
Kawachi, Toru [7 ]
Katayose, Tetsurou [7 ]
Mizuno, Norifumi [1 ]
Miyasaka, Ryohei [2 ,7 ]
Saitoh, Hidetoshi [2 ]
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, Chuo Ku, 9-1 Akashi Cho, Tokyo 1048560, Japan
[2] Tokyo Metropolitan Univ, Grad Sch Human Hlth Sci, Arakawa Ku, 7-2-10 Higashi Ogu, Tokyo 1160012, Japan
[3] Saitama Med Univ, Int Med Ctr, Dept Radiat Oncol, 1397-1 Yamane, Hidaka City, Saitama 3501298, Japan
[4] Natl Hosp Org Tokyo Natl Hosp, Div Radiat, 3-1-1 Takeoka, Kiyose, Tokyo 2048585, Japan
[5] Saitama Med Univ, Saitama Med Ctr, Dept Radiat Oncol, 1981 Kamoda, Kawagoe, Saitama 3508550, Japan
[6] Komagome Hosp, Tokyo Metropolitan Canc & Infect Dis Ctr, Dept Radiotherapy, Bunkyo Ku, 3-18-22 Honkomagome, Tokyo 1138677, Japan
[7] Chiba Canc Ctr, Dept Radiat Oncol, Chuo Ku, 666-2 Nitona Cho, Chiba 2608717, Japan
关键词
cable effect; Compton current; dosimetry; ionization chamber; leakage current; IONIZATION-CHAMBER; STEM LEAKAGE; DOSIMETRY; COMMITTEE;
D O I
10.1002/mp.14450
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Ionization chambers are widely used for dosimetry with megavoltage photon beams. Several properties of ionization chambers, including the cable effect, polarity effect, and ion recombination loss, are described in standard dosimetry protocols. The cable effect is categorized as the leakage current and Compton current, and careful consideration of these factors has been described not only in reference dosimetry but also in large fields. However, the mechanism of Compton current in the cable has not been investigated thoroughly. The cable effect of ionization chambers in 6 MV X-ray beam was evaluated by measurement, and the mechanism of Compton current was investigated by Monte Carlo simulation. Materials and Methods Four PTW ionization chambers (TM30013, TM31010, TM31014, and TM31016) with the same type of mounted cable, but different ionization volumes, were used to measure output factor (OPF) and cable effect measurement. The OPF was measured to observe any variation resulting from the cable effect. The cable effect was evaluated separately for the leakage current and Compton current, and its charge per absorbed dose to water per cable length was estimated by a newly proposed method. The behavior of electrons and positrons in the core wire was analyzed and the Compton current for the photon beam was estimated by Monte Carlo simulation. Results In OPF measurement, the difference in the electrometer readings by polarity became obvious for the mini- or microchamber and its difference tended to be larger for a chamber with a smaller ionization volume. For the cable effect measurement, it was determined that the contribution of the leakage current to the cable effect was ignorable, while the Compton current was dominant. The charge due to the Compton current per absorbed dose to water per cable length was estimated to be 0.36 +/- 0.03 pC Gy(-1) cm(-1)for PTW ionization chambers. As a result, the contribution of the Compton current to the electrometer readings was estimated to be 0.002% cm(-1)for the Farmer-type, 0.011% cm(-1)for the scanning, and 0.088% cm(-1)for microchambers, respectively. By the simulation, it was determined that the Compton current for MV x-ray could be explained by not only recoil electrons due to Compton scattering but also positron due to pair production. The Compton current estimated by the difference in outflowing and inflowing charge was 0.45 pC Gy(-1) cm(-1)and was comparable with the measured value. Conclusion The cable effect, which includes the leakage current and Compton current, was quantitatively estimated for several chambers from measurements, and the mechanism of Compton current was investigated by Monte Carlo simulation. It was determined that the Compton current is a dominant component of the cable effect and its charge is consistently positive and nearly the same, irrespective of the ionization chamber volume. The contribution of Compton current to the electrometer readings was estimated for chambers. The mechanism of Compton current was analyzed and it was confirmed that the Compton current can be estimated from the difference in outflowing and inflowing charge to and from the core wire.
引用
收藏
页码:5324 / 5332
页数:9
相关论文
共 50 条
  • [1] Estimation of Cable Leakage of Ionization Chamber in Megavoltage Photon Beam by Monte Carlo Simulation and Theoretical Analysis
    Yamauchi, R.
    Igari, M.
    Kasai, Y.
    Hariu, M.
    Suda, Y.
    Kawachi, T.
    Katayose, T.
    Mizuno, N.
    Miyasaka, R.
    Saitoh, H.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E459 - E460
  • [2] Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters
    Sheikh-Bagheri, D
    Rogers, DWO
    [J]. MEDICAL PHYSICS, 2002, 29 (03) : 379 - 390
  • [3] Monte Carlo linear accelerator simulation of megavoltage photon beams: Independent determination of initial beam parameters
    Almberg, Sigrun Saur
    Frengen, Jomar
    Kylling, Arve
    Lindmo, Tore
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 40 - 47
  • [4] Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    Sheikh-Bagheri, D
    Rogers, DWO
    [J]. MEDICAL PHYSICS, 2002, 29 (03) : 391 - 402
  • [5] Monte Carlo source model for megavoltage photon-beam radiotherapy: Photon source characteristics
    Fix, M
    Keall, P
    Libby, B
    Mohan, R
    Siebers, J
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1904 - 1904
  • [6] On Monte Carlo Modeling of Megavoltage Photon Beams: A Revisited Study on Beam Parameters Sensitivity
    Chibani, O.
    Moftah, B.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [7] On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters
    Chibani, Omar
    Moftah, Belal
    Ma, C. -M. Charlie
    [J]. MEDICAL PHYSICS, 2011, 38 (01) : 188 - 201
  • [8] The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments
    Mobit, PN
    Mayles, P
    Nahum, AE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03): : 387 - 398
  • [9] Radiation induced currents in parallel plate ionization chambers: Measurement and Monte Carlo simulation for megavoltage photon and electron beams
    Abdel-Rahman, Warnied
    Seuntjens, Jan P.
    Verhaegen, Frank
    Podgorsak, Ervin B.
    [J]. MEDICAL PHYSICS, 2006, 33 (09) : 3094 - 3104
  • [10] An estimation of relative output factors of 6 MV photon beam using Monte Carlo simulation
    Saprangsi, W.
    Phaisangittisakul, N.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2416 - 2416