Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code

被引:380
|
作者
Sheikh-Bagheri, D [1 ]
Rogers, DWO [1 ]
机构
[1] Natl Res Council Canada, Ionizing Radiat Standards, Ottawa, ON K1A 0R6, Canada
关键词
Monte Carlo; photon spectra; electron contamination; head-scatter; mega-voltage photon beams;
D O I
10.1118/1.1445413
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A recent paper analyzed the sensitivity to various simulation parameters of the Monte Carlo simulations of nine beams from three major manufacturers of commercial medical linear accelerators, ranging in energy from 4-25 MV. In this work the nine models are used: to calculate photon energy spectra and average energy distributions and compare them to those published by Mohan et at. [Med. Phys. 12, 592-597 (1985)]; to separate the spectra into primary and scatter components from the primary collimator, the flattening filter and the adjustable collimators; and to calculate the contaminant-electron fluence spectra and the electron contribution to the depth-dose curves. Notwithstanding the better precision of the calculated spectra, they are similar to those calculated by Mohan et al. The three photon spectra at 6 MV from the machines of three different manufacturers show differences in their shapes as well as in the efficiency of bremsstrahlung production in the corresponding target and filter combinations. The contribution of direct photons to the photon energy fluence in a 10 X 10 field varies between 92% and 97%, where the primary collimator contributes between 0.6% and 3.4% and the flattening filter contributes between 0.6% and 4.5% to the head-scatter energy fluence. The fluence of the contaminant electrons at 100 cm varies between 5 X 10(-9)) and 2.4 X 10(-7) cm(-2) per incident electron on target, and the corresponding spectrum for each beam is relatively invariant inside a 10 X 10 cm(2) field. On the surface the dose from electron contamination varies between 5.7% and 11% of maximum dose and, at the depth of maximum dose, between 0.16% and 2.5% of maximum dose. The photon component of the percentage depth-dose at 10 cm depth is compared with the general formula provided by AAPM's task group 51 and confirms the claimed accuracy of 2%. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:391 / 402
页数:12
相关论文
共 50 条
  • [1] Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters
    Sheikh-Bagheri, D
    Rogers, DWO
    [J]. MEDICAL PHYSICS, 2002, 29 (03) : 379 - 390
  • [2] Photon Spectra calculation for an Elekta linac beam using experimental scatter measurements and Monte Carlo techniques
    Juste, B.
    Miro, R.
    Campayo, J. M.
    Diez, S.
    Verdu, G.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3289 - +
  • [3] MONTE-CARLO CALCULATION OF THE PHOTON-BEAM SPECTRA OF A DUAL ENERGY LINAC
    BOYER, AL
    CASSADY, AE
    WANG, LL
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 452 - 452
  • [4] Estimation of the cable effect in megavoltage photon beam by measurement and Monte Carlo simulation
    Yamauchi, Ryohei
    Igari, Mitsunobu
    Kasai, Yuya
    Hariu, Masatsugu
    Suda, Yuhi
    Kawachi, Toru
    Katayose, Tetsurou
    Mizuno, Norifumi
    Miyasaka, Ryohei
    Saitoh, Hidetoshi
    [J]. MEDICAL PHYSICS, 2020, 47 (10) : 5324 - 5332
  • [5] Monte Carlo source model for megavoltage photon-beam radiotherapy: Photon source characteristics
    Fix, M
    Keall, P
    Libby, B
    Mohan, R
    Siebers, J
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1904 - 1904
  • [6] On Monte Carlo Modeling of Megavoltage Photon Beams: A Revisited Study on Beam Parameters Sensitivity
    Chibani, O.
    Moftah, B.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [7] On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters
    Chibani, Omar
    Moftah, Belal
    Ma, C. -M. Charlie
    [J]. MEDICAL PHYSICS, 2011, 38 (01) : 188 - 201
  • [8] Photon beam softening coefficients evaluation for a 6 MeV photon beam for an aluminum slab: Monte Carlo study using BEAMnrc Code, DOSXYZnrc Code, and BEAMDP code
    Mohamed Bencheikh
    Abdelmajid Maghnouj
    Jaouad Tajmouati
    [J]. Moscow University Physics Bulletin, 2017, 72 : 263 - 270
  • [9] Photon Beam Softening Coefficients Evaluation for a 6 MeV Photon Beam for an Aluminum Slab: Monte Carlo Study Using BEAMnrc Code, DOSXYZnrc Code, and BEAMDP Code
    Bencheikh, Mohamed
    Maghnouj, Abdelmajid
    Tajmouati, Jaouad
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (03) : 263 - 270
  • [10] A Method for Automatic Commissioning of a GPU-Based Monte Carlo Code for Clinica Photon Beam Dose Calculation
    Tian, Z.
    Townson, R.
    Graves, Y.
    Jia, X.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)