VALIDATION OF MONTE CARLO SIMULATION OF A THYROID UPTAKE SYSTEM USING VARIOUS SOURCES AND A SLAB PHANTOM

被引:3
|
作者
Scarboro, Sarah [1 ]
Hertel, Nolan [1 ]
Burgett, Eric [1 ]
Howell, Rebecca [2 ]
Ansari, Armin [3 ]
机构
[1] Georgia Inst Technol, Atlanta, GA 30332 USA
[2] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
[3] Ctr Dis Control & Prevent, Radiat Studies Branch, Atlanta, GA USA
关键词
thyroid uptake system; radiological dispersal device; internal contamination;
D O I
10.13182/NT09-A9120
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the event of a terrorist act involving a radiological agent, internal contamination due to inhalation is a potential health threat. When a large population is potentially impacted, there is need for methodology to serve as an initial screening or triage tool to rapidly identify individuals with significant amounts of internal contamination and to assist in prioritizing collection of large numbers of bioassay samples needed in such an incident. Common handheld radiation detectors and medical devices are tools that can effectively and rapidly screen a large number of people for internal contamination due to gamma-emitting isotopes. This work investigated the use of a common medical device, a thyroid uptake system or thyroid probe, in screening for internal contamination in individuals. The response of a thyroid uptake system in such a situation can be estimated by using a validated Monte Carlo model of the thyroid uptake system and various human phantoms. A computational model of the thyroid uptake system was built using the Los Alamos Particle Transport Code, MCNP Version 5. The validation of this computational model was demonstrated by comparisons to a series of benchmark measurements using the actual device and six isotopes with a range of gamma-ay emission energies.
引用
收藏
页码:169 / 172
页数:4
相关论文
共 50 条
  • [1] Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom
    Toshimune Ito
    Hirotatsu Tsuchikame
    Hajime Ichikawa
    Masahisa Onoguchi
    Koichi Okuda
    Takayuki Shibutani
    Noriyo Yokotsuka
    Hiroshi Tomizawa
    [J]. Radiological Physics and Technology, 2021, 14 : 336 - 344
  • [2] Verification of phantom accuracy using a Monte Carlo simulation: bone scintigraphy chest phantom
    Ito, Toshimune
    Tsuchikame, Hirotatsu
    Ichikawa, Hajime
    Onoguchi, Masahisa
    Okuda, Koichi
    Shibutani, Takayuki
    Yokotsuka, Noriyo
    Tomizawa, Hiroshi
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (03) : 336 - 344
  • [3] Monte Carlo simulation of a mammographic test phantom
    Hunt, RA
    Dance, DR
    Pachoud, M
    Carlsson, GA
    Sandborg, M
    Ullman, G
    Verdun, FR
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 432 - 435
  • [4] Evaluation of dosimetric parameters for various 192ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation
    Devan, Krishnamurthy
    Aruna, Prakasarao
    Manigandan, Durai
    Bharanidharan, Ganesan
    Subbaiah, Kamatam Venkata
    Sunny, Chiravath Sunil
    Ganesan, Singaravelu
    [J]. MEDICAL DOSIMETRY, 2007, 32 (04) : 305 - 315
  • [5] Monte-Carlo simulation and tissue-phantom model for validation of ocular oximetry
    Akitegetse, Cleophace
    Landry, Patricia
    Robidoux, Jonathan
    Lapointe, Nicolas
    Brouard, Danny
    Sauvageau, Dominic
    [J]. BIOMEDICAL OPTICS EXPRESS, 2022, 13 (05) : 2929 - 2946
  • [6] Validation of a Monte Carlo Radiographic Simulation
    Gearhart, A.
    Carver, D.
    Stabin, M.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3405 - 3405
  • [7] Airport Surveillance Requirements Validation using Monte Carlo Simulation
    Campbell, Steven D.
    Londner, Edward
    Keefe, James
    Edwards, Christopher
    [J]. 2014 Tyrrhenian International Workshop on Digital Communications: Enhanced Surveillance of Aircraft and Vehicles (TIWDC/ESAV), 2014, : 29 - 34
  • [8] Hybrid Microscale Phantom of Kidney for Monte Carlo Simulation
    Jabbary M.
    [J]. Mathematical Models and Computer Simulations, 2022, 14 (6) : 1032 - 1043
  • [9] Monitoring Focal Laser Ablation with Interstitial Fluence Probes: Monte Carlo Simulation and Phantom Validation
    Geoghegan, Rory
    Priester, Alan
    Zhang, Le
    Wu, Holden
    Marks, Leonard
    Natarajan, Shyam
    [J]. 42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5272 - 5275
  • [10] Evaluation of Shrinking Direction of Movement Using Monte Carlo Simulation in A Rectangular Slab
    Udoye, N. E.
    Dare, A. A.
    Fayomi, O. S. I.
    Uguru-okorie, D. C.
    [J]. 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS PROCESSING AND MANUFACTURING (SMPM 2019), 2019, 35 : 1370 - 1374