Calcium phosphate cement augmentation after volar locking plating of distal radius fracture significantly increases stability

被引:11
|
作者
Kainz H. [1 ]
Dall'Ara E. [2 ]
Antoni A. [1 ]
Redl H. [1 ]
Zysset P. [2 ]
Weninger P. [1 ]
机构
[1] Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Donaueschingenstraße 13
[2] Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna
关键词
Biomaterial; Biomechanics; Distal radius fracture; Fracture fixation; Volar plating;
D O I
10.1007/s00590-013-1285-z
中图分类号
学科分类号
摘要
Purpose: Distal radius fractures represent the most common fractures in adults. Volar locking plating to correct unstable fractures has become increasingly popular. Although reasonable primary reduction is possible in most cases, maintenance of reduction until the fracture is healed is often problematic in osteoporotic bone. To our knowledge, no biomechanical studies have compared the effect of enhancement with biomaterial on two different volar fixed-angle plates. Methods: Human fresh-frozen cadaver pairs of radii were used to simulate an AO/OTA 23-A3 fracture. In a total of four groups (n = 7 for each group), two volar fixed-angle plates (Aptus 2.5 mm locking fracture plate, Medartis, Switzerland and VA-LCP two-column distal radius plate 2.4, volar, Synthes, Switzerland) with or without an additional injection of a biomaterial (Hydroset Injectable HA Bone Substitute, Stryker, Switzerland) into the dorsal comminution zone were used to fix the distal metaphyseal fragment. Each specimen was tested load-controlled under cyclic loading with a servo-hydraulic material testing machine. Displacement, stiffness, dissipated work and failure mode were recorded. Results: Improved mechanical properties (decreased displacement, increased stiffness, decreased dissipated work) were found in both plates if the biomaterial was additionally injected. Improvement of mechanical parameters after biomaterial injection was more evident in the Synthes plate compared to the Aptus plate. Pushing out of the screws was noticed as a failure mode only in samples lacking supplementary biomaterial. Conclusions: Injection of a biomaterial into the dorsal comminution zone increases stability after volar locking plating of distal radius fractures in vitro. © 2013 Springer-Verlag.
引用
收藏
页码:869 / 875
页数:6
相关论文
共 50 条
  • [31] Clinical and Radiological Results after Distal Radius Fracture: Intramedullary Locking Nail versus Volar Locking Plate Osteosynthesis
    Lerch, S.
    Sextro, H. -G.
    Wilken, F.
    Wittenberg, C. E.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2009, 147 (05): : 547 - 552
  • [32] Functional Outcome of Intraarticular Fracture of Distal Radius Managed by Volar Locking Plate
    Ahmed, Masroor
    Ahmed, Naveed
    Kumar, Sunil
    Kumar, Mukesh
    Bux, Muhammad
    Hussain, Ghulam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (10)
  • [33] Incidence for volar locking plate removal following distal radius fracture surgery
    Vili Palola
    Ville Ponkilainen
    Tuomas Huttunen
    Antti Launonen
    Ville M. Mattila
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1297 - 1302
  • [34] Incidence for volar locking plate removal following distal radius fracture surgery
    Palola, Vili
    Ponkilainen, Ville
    Huttunen, Tuomas
    Launonen, Antti
    Mattila, Ville M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (08) : 1297 - 1302
  • [35] Damage in a Distal Radius Fracture Model Treated With Locked Volar Plating After Simulated Postoperative Loading
    Salas, Christina
    Brantley, Justin A.
    Clark, James
    Taha, Mahmoud Reda
    Myers, Orrin B.
    Mercer, Deana
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (07): : 679.e1 - 679.e6
  • [36] Safe Return to Driving After Volar Plating of Distal Radius Fractures
    Jones, Chiistopher M.
    Ramsey, Randle W.
    Ilyas, Asif
    Abboudi, Jack
    Kirkpatrick, William
    Kalina, Thomas
    Leinberry, Charles
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09): : 700 - 704
  • [37] Using Trident distal radial locking plate to fix the fracture of distal radius volar rim
    Huang, Yin-Ming
    Chen, Chun-Yu
    Lin, Kai-Cheng
    Lai, Wei-Yi
    Lin, Yi-Ying
    Fu, Yun-Ju
    Tarng, Yih-Wen
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2023, 86 (04) : 426 - 430
  • [38] Complications after volar locking plate fixation of distal radius fractures
    Johnson, N. A.
    Cutler, L.
    Dias, J. J.
    Ullah, A. S.
    Wildin, C. J.
    Bhowal, B.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (03): : 528 - 533
  • [39] Dorsal screw penetration following implant removal after volar locked plating of distal radius fracture
    Haug, Luzian C. P.
    Deml, Christian
    Blauth, Michael
    Arora, Rohit
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1279 - 1282
  • [40] Volar locking plate removal after distal radius fracture: a 10-year retrospective study
    Jun-Ku Lee
    Younghun Lee
    Choongki Kim
    Minwook Kim
    Soo-Hong Han
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1711 - 1719