Calcium phosphate cement augmentation after volar locking plating of distal radius fracture significantly increases stability

被引:11
|
作者
Kainz H. [1 ]
Dall'Ara E. [2 ]
Antoni A. [1 ]
Redl H. [1 ]
Zysset P. [2 ]
Weninger P. [1 ]
机构
[1] Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Donaueschingenstraße 13
[2] Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna
关键词
Biomaterial; Biomechanics; Distal radius fracture; Fracture fixation; Volar plating;
D O I
10.1007/s00590-013-1285-z
中图分类号
学科分类号
摘要
Purpose: Distal radius fractures represent the most common fractures in adults. Volar locking plating to correct unstable fractures has become increasingly popular. Although reasonable primary reduction is possible in most cases, maintenance of reduction until the fracture is healed is often problematic in osteoporotic bone. To our knowledge, no biomechanical studies have compared the effect of enhancement with biomaterial on two different volar fixed-angle plates. Methods: Human fresh-frozen cadaver pairs of radii were used to simulate an AO/OTA 23-A3 fracture. In a total of four groups (n = 7 for each group), two volar fixed-angle plates (Aptus 2.5 mm locking fracture plate, Medartis, Switzerland and VA-LCP two-column distal radius plate 2.4, volar, Synthes, Switzerland) with or without an additional injection of a biomaterial (Hydroset Injectable HA Bone Substitute, Stryker, Switzerland) into the dorsal comminution zone were used to fix the distal metaphyseal fragment. Each specimen was tested load-controlled under cyclic loading with a servo-hydraulic material testing machine. Displacement, stiffness, dissipated work and failure mode were recorded. Results: Improved mechanical properties (decreased displacement, increased stiffness, decreased dissipated work) were found in both plates if the biomaterial was additionally injected. Improvement of mechanical parameters after biomaterial injection was more evident in the Synthes plate compared to the Aptus plate. Pushing out of the screws was noticed as a failure mode only in samples lacking supplementary biomaterial. Conclusions: Injection of a biomaterial into the dorsal comminution zone increases stability after volar locking plating of distal radius fractures in vitro. © 2013 Springer-Verlag.
引用
收藏
页码:869 / 875
页数:6
相关论文
共 50 条
  • [21] Flexor tendon rupture after volar plating of distal radius fracture: A systematic review of the literature
    Floquet, A.
    Druart, T.
    Lavantes, P.
    Vendeuvre, T.
    Delaveau, A.
    HAND SURGERY & REHABILITATION, 2021, 40 (05): : 535 - 546
  • [22] Rupture of Flexor Pollicis Longus Tendon: A Complication of Volar Locking Plating of the Distal Radius
    Aysha Sethunathan Rajeev
    Shanaka Sreverthana
    John Harrison
    European Journal of Trauma and Emergency Surgery, 2010, 36 : 385 - 387
  • [23] Volar Locking Plating of Extra-articular Distal Radius Fracture: A Retrospective Clinical Study Comparing Locking Screws versus Smooth Locking Pegs
    Tordjman, Daniel
    Younis, Mohammad
    Factor, Shai
    Eisenberg, Gilad
    Atlan, Franck
    McBeth, Jessica
    Pritsch, Tamir
    Rosenblatt, Yishai
    JOURNAL OF WRIST SURGERY, 2024, 13 (02) : 151 - 157
  • [24] Rupture of Flexor Pollicis Longus Tendon: A Complication of Volar Locking Plating of the Distal Radius
    Rajeev, Aysha Sethunathan
    Sreverthana, Shanaka
    Harrison, John
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2010, 36 (04) : 385 - 387
  • [25] A new complication in volar locking plating of the distal radius: longitudinal fractures of the near cortex
    Sugun, Tahir Sadik
    Gurbuz, Yusuf
    Ozaksar, Kemal
    Toros, Tulgar
    Bal, Emin
    Kayalar, Murat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2016, 50 (02) : 147 - 152
  • [26] Mid-Term Results after Volar Plating of Distal Radius Fractures with a Newly Designed Locking Plate
    Wick, M.
    Wiesner, M.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (01): : 66 - 71
  • [27] Biopsies from the Distal Radius after Implantation of Calcium Phosphate Cement
    Winge, Mona, I
    Johansson, Carina B.
    Rokkum, Magne
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2022, 27 (05): : 852 - 863
  • [28] Radiographic Change in Articular Reduction After Volar Locking Plating for Intra-Articular Distal Radius Fractures
    Hashimoto, Shun
    Yamazaki, Hiroshi
    Hayashi, Masanori
    Isobe, Fumihiro
    Miyaoka, Shunsuke
    Kitamura, Yo
    Kato, Hiroyuki
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (04): : 335 - 340
  • [29] Evaluation of radiographic fracture position 1 year after variable angle locking volar distal radius plating: a prospective multicentre case series
    Teunis, T.
    Jupiter, J.
    Schaser, K. D.
    Fronhoefer, G.
    Babst, R.
    Langer, M.
    Platz, A.
    Schierz, A.
    Joeris, A.
    Rikli, D.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2017, 42 (05) : 493 - 500
  • [30] Primary repair of extensor pollicis longus rupture after volar locking plating for distal radial fracture
    Cha, S. M.
    Shin, H. D.
    Shin, J. W.
    HAND SURGERY & REHABILITATION, 2022, 41 (04): : 500 - 507