Incidence for volar locking plate removal following distal radius fracture surgery

被引:12
|
作者
Palola, Vili [1 ]
Ponkilainen, Ville [2 ]
Huttunen, Tuomas [3 ,4 ,5 ]
Launonen, Antti [2 ]
Mattila, Ville M. [1 ,2 ,6 ]
机构
[1] Tampere Univ, Fac Med & Hlth Technol, Tampere 33520, Finland
[2] Tampere Univ Hosp, Dept Orthopaed & Traumatol, Tampere, Finland
[3] Tampere Univ, Tampere Univ Hosp, Fac Med & Hlth Technol, Tampere, Finland
[4] Tampere Univ Hosp, Dept Emergency Anesthesia & Pain Med, Tampere, Finland
[5] Karolinska Inst, Div Orthoped & Biotechnol, Dept Clin Sci Intervent & Technol CLINTEC, Stockholm, Sweden
[6] COXA Hosp Joint Replacement, Biokatu 6, Tampere 33520, Finland
关键词
Distal radius fracture; Surgery; Volar plate; Plate removal; Epidemiology; UNITED-STATES; CHANGING EPIDEMIOLOGY; INTERNAL-FIXATION; ADULT FRACTURES; COMPLICATIONS;
D O I
10.1007/s00402-020-03565-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Distal radius fracture is the most common fracture in adults. The most common treatment for distal radius fracture is non-operative cast immobilization, although there are injuries that require surgical treatment. During the past decade, studies have reported a large increase in the surgical treatment of distal radius fractures with open reduction and internal fixation using volar locking plates. The aim of this study was to investigate the incidence and trends for plate removal after plate fixation of distal radius fractures. Materials and methods The study covered all patients 18 years of age and older who had a surgically treated distal radius fracture with open reduction and internal fixation in Finland between 1998 and 2016. Patient data were obtained from the Finnish National Hospital Discharge Register. The association between increased number of platings and plate removals was examined by calculating the removal rates. The study population comprises all patients on a national level, and therefore we did not use statistical testing to analyze the data. Results A total of 18,298 patients had surgically treated distal radius fracture with volar plate in Finland during the 19-year study period from January 1, 1998 to December 31, 2016. The number of plate removal operations over the same time period was 2560. The removal rates decreased from over 20% in 1998 to less than 12% in 2016. The mean time period between plating and plate removal operations was 367 days. Most of the plate removals (n = 2235; 87.3%) were conducted during the first 2 years after plating. Conclusion Plate removals have not increased as rapidly as plating operations. The removal rate has declined markedly during the last decade. Nowadays, approximately 11% of distal radius plates are removed.
引用
收藏
页码:1297 / 1302
页数:6
相关论文
共 50 条
  • [1] Incidence for volar locking plate removal following distal radius fracture surgery
    Vili Palola
    Ville Ponkilainen
    Tuomas Huttunen
    Antti Launonen
    Ville M. Mattila
    [J]. Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1297 - 1302
  • [2] Incidence of Hardware Removal Following Volar Plate Fixation of Distal Radius Fracture
    Lutsky, Kevin F.
    Beredjiklian, Pedro K.
    Hioe, Stephen
    Bilello, Justin
    Kim, Nayoung
    Matzon, Jonas L.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (12): : 2410 - 2415
  • [3] A systematic review of volar locking plate removal after distal radius fracture
    Yamamoto, Michiro
    Fujihara, Yuki
    Fujihara, Nasa
    Hirata, Hitoshi
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (12): : 2650 - 2656
  • [4] Treatment of distal clavicle fracture with distal radius volar locking compression plate
    Yu Chao
    Sun Yue-hua
    Zhao Chang-qing
    Shi Ding-wei
    Wang You
    [J]. CHINESE JOURNAL OF TRAUMATOLOGY, 2009, 12 (05) : 299 - 301
  • [5] Treatment of distal clavicle fracture with distal radius volar locking compression plate
    俞超
    孙月华
    赵长清
    史定伟
    王友
    [J]. 中华创伤杂志(英文版), 2009, (05) : 299 - 301
  • [6] Functional Outcome of Volar Locking Plate Fixation in Distal Radius Fracture
    Raza, Shahid
    Raza, Sibtain
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2018, 12 (01): : 330 - 333
  • [7] Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
    Shinohara, Takaaki
    Hirata, Hitoshi
    [J]. NAGOYA JOURNAL OF MEDICAL SCIENCE, 2017, 79 (04): : 551 - 557
  • [8] Volar locking plate removal after distal radius fracture: a 10-year retrospective study
    Jun-Ku Lee
    Younghun Lee
    Choongki Kim
    Minwook Kim
    Soo-Hong Han
    [J]. Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1711 - 1719
  • [9] Volar locking plate removal after distal radius fracture: a 10-year retrospective study
    Lee, Jun-Ku
    Lee, Younghun
    Kim, Choongki
    Kim, Minwook
    Han, Soo-Hong
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (10) : 1711 - 1719
  • [10] Functional Outcome of Intraarticular Fracture of Distal Radius Managed by Volar Locking Plate
    Ahmed, Masroor
    Ahmed, Naveed
    Kumar, Sunil
    Kumar, Mukesh
    Bux, Muhammad
    Hussain, Ghulam
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (10)