Fabric phase sorptive extraction followed by UHPLC-MS/MS for the analysis of benzotriazole UV stabilizers in sewage samples

被引:0
|
作者
Sarah Montesdeoca-Esponda
Zoraida Sosa-Ferrera
Abuzar Kabir
Kenneth G. Furton
José Juan Santana-Rodríguez
机构
[1] Universidad de Las Palmas de G.C.,Departamento de Química
[2] Florida International University,International Forensic Research Institute, Department of Chemistry and Biochemistry
来源
关键词
Benzotriazole UV stabilizers; Fabric phase sorptive extraction; UHPLC-MS/MS; Sewage samples; Personal care products; Emerging pollutants; Green sample preparation;
D O I
暂无
中图分类号
学科分类号
摘要
A fast and sensitive sample preparation strategy using fabric phase sorptive extraction followed by ultra-high-performance liquid chromatography and tandem mass spectrometry detection has been developed to analyse benzotriazole UV stabilizer compounds in aqueous samples. Benzotriazole UV stabilizer compounds are a group of compounds added to sunscreens and other personal care products which may present detrimental effects to aquatic ecosystems. Fabric phase sorptive extraction is a novel solvent minimized sample preparation approach that integrates the advantages of sol–gel derived hybrid inorganic–organic nanocomposite sorbents and the flexible, permeable and hydrophobic surface chemistry of polyester fabric. It is a highly sensitive, fast, efficient and inexpensive device that can be reused and does not suffer from coating damage, unlike SPME fibres or stir bars. In this paper, we optimized the extraction of seven benzotriazole UV filters evaluating the majority of the parameters involved in the extraction process, such as sorbent chemistry selection, extraction time, back-extraction solvent, back-extraction time and the impact of ionic strength. Under the optimized conditions, fabric phase sorptive extraction allows enrichment factors of 10 times with detection limits ranging from 6.01 to 60.7 ng L−1 and intra- and inter-day % RSDs lower than 11 and 30 % for all compounds, respectively. The optimized sample preparation technique followed by ultra-high-performance liquid chromatography and tandem mass spectrometry detection was applied to determine the target analytes in sewage samples from wastewater treatment plants with different purification processes of Gran Canaria Island (Spain). Two UV stabilizer compounds were measured in ranges 17.0–60.5 ng mL−1 (UV 328) and 69.3–99.2 ng mL−1 (UV 360) in the three sewage water samples analysed.
引用
收藏
页码:8137 / 8150
页数:13
相关论文
共 50 条
  • [31] SOLID-PHASE EXTRACTION COMBINED WITH UHPLC-MS/MS METHOD FOR DETERMINATION OF REMIFENTANIL IN HUMAN WHOLE BLOOD
    Lv, Jinling
    Li, Yanhua
    Jin, Hua
    Shi, Yao
    Xia, Qinghai
    Yang, Yaling
    [J]. ANALYTICAL LETTERS, 2012, 45 (10) : 1133 - 1142
  • [32] Determination of triazole fungicides in environmental water by magnetic solid-phase extraction coupled with UHPLC-MS/MS
    Sun, Peng
    Gao, Yuling
    Lian, Yongfu
    [J]. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (07) : 1483 - 1489
  • [33] Determination of triazole fungicides in environmental water by magnetic solid-phase extraction coupled with UHPLC-MS/MS
    Peng Sun
    Yuling Gao
    Yongfu Lian
    [J]. Journal of the Iranian Chemical Society, 2019, 16 : 1483 - 1489
  • [34] Graphene oxide-Fe3O4 nanocomposite magnetic solid phase extraction followed by UHPLC-MS/MS for highly sensitive determination of eight psychoactive drugs in urine samples
    Lu, Qing
    Guo, Hao
    Zhang, Yuanyuan
    Tang, Xiaodong
    Lei, Weibin
    Qi, Ruijuan
    Chu, Junhao
    Li, Dezeng
    Zhao, Qingbiao
    [J]. TALANTA, 2020, 206
  • [35] Streamlined Method for Pesticide Residues in High-Lipid Food Samples Using QuEChERS Extraction, LipiFiltr® Cleanup, and UHPLC-MS/MS Analysis
    Bhattarai, Bikash
    Kinsella, Brian
    [J]. LC GC EUROPE, 2018, 31 (09) : 528 - 528
  • [36] Flow analysis-solid phase extraction system and UHPLC-MS/MS analytical methodology for the determination of antiviral drugs in surface water
    Karolina Mermer
    Emilia Jas
    Justyna Paluch
    Aneta Woźniakiewicz
    Michał Woźniakiewicz
    Paweł Miśkowiec
    Petr Chocholouš
    Hana Sklenářová
    Joanna Kozak
    [J]. Environmental Science and Pollution Research, 2024, 31 (37) : 49546 - 49559
  • [37] A multiclass method for endocrine disrupting chemical residue analysis in human placental tissue samples by UHPLC-MS/MS
    Vela-Soria, F.
    Jimenez-Diaz, I.
    Rodriguez-Gomez, R.
    Zafra-Gomez, A.
    Ballesteros, O.
    Fernandez, M. F.
    Olea, N.
    Navalon, A.
    [J]. ANALYTICAL METHODS, 2011, 3 (09) : 2073 - 2081
  • [38] Determination of 19 sulfonamides residues in pork samples by combining QuEChERS with dispersive liquid-liquid microextraction followed by UHPLC-MS/MS
    Li, Xiaojing
    Yu, Hong
    Peng, Rongfei
    Gan, Pingsheng
    [J]. JOURNAL OF SEPARATION SCIENCE, 2017, 40 (06) : 1377 - 1384
  • [39] Analysis of bromophenols in various aqueous samples using solid phase extraction followed by HPLC-MS/MS
    Chi, Xiyuan
    Liu, Jiyan
    Yu, Miao
    Xie, Zhouqing
    Jiang, Guibin
    [J]. TALANTA, 2017, 164 : 57 - 63
  • [40] Bioanalysis of dried saliva spot (DSS) samples using detergent-assisted sample extraction with UHPLC-MS/MS detection
    Zheng, Naiyu
    Zeng, Jianing
    Ji, Qin C.
    Angeles, Aida
    Aubry, Anne-Francoise
    Basdeo, Shenita
    Buzescu, Adela
    Landry, Ishani Savant
    Jariwala, Navin
    Turley, Wesley
    Burrell, Richard
    Arnold, Mark E.
    [J]. ANALYTICA CHIMICA ACTA, 2016, 934 : 170 - 179