Analysis of bromophenols in various aqueous samples using solid phase extraction followed by HPLC-MS/MS

被引:33
|
作者
Chi, Xiyuan [1 ,2 ]
Liu, Jiyan [1 ,3 ]
Yu, Miao [1 ,3 ]
Xie, Zhouqing [2 ]
Jiang, Guibin [1 ,3 ]
机构
[1] Chinese Acad Sci, State Key Lab Environm Chem & Ecotoxixol, Res Ctr Ecoenvironm Sci, POB 2871, Beijing 100085, Peoples R China
[2] Univ Sci & Technol China, Sch Earth & Space Sci, Inst Polar Environm, Hefei 230026, Anhui, Peoples R China
[3] Univ Chinese Acad Sci, Coll Resources & Environm, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Bromophenols; Solid phase extraction; LC-MS/MS; Aqueous samples; BROMINATED FLAME RETARDANTS; POLYBROMINATED DIPHENYL ETHERS; PHENOLIC-COMPOUNDS; TETRABROMOBISPHENOL-A; MASS-SPECTROMETRY; BY-PRODUCTS; OCEAN FISH; WATER; CHLOROPHENOLS; PRECONCENTRATION;
D O I
10.1016/j.talanta.2016.11.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reliable and effective method for simultaneous analysis of trace amount of bromophenols (BPs) in various aqueous samples was developed in this study. The aqueous samples must be acidified after sampling to prevent the fast degradation of bromophenols. Solid-phase extraction was chosen to extract and purify the water samples. High performance liquid chromatography coupled with tandem mass spectrometry with an electrospray ionization source (HPLC-ESI-MS/MS) was used for following identification and quantification. Under the optimized condition, fourteen out of fifteen target brominated phenols were successfully separated and detected with the exception of 2,6-bromophenol (2,6-BP) whose response was too low to be quantified by the MS detector. The method was validated by spiking river water and seawater samples with different concentrations of BPs, and the qualified spiking recoveries (64-100%) and precisions (0.4-11% RSD) were obtained. The method detection limits were 0.1-13.9 ng/L and 0.1-21.9 ng/L for 0.1 L of river water and seawater samples, respectively, showing the influences from the sample matrix. The proposed method was successfully applied to the analysis of bromophenol contamination in real water samples, and six bromophenols were identified with a wide concentrations ranging from ng/L to 1.1g/L.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [1] Surface molecularly imprinted solid-phase extraction for the determination of vancomycin in plasma samples using HPLC-MS/MS
    Zhou, Hao
    Chen, Qianqian
    Song, Xuqin
    He, Limin
    Liu, Rong
    ANALYTICAL SCIENCES, 2022, 38 (09) : 1171 - 1179
  • [2] Simultaneous determination of four biogenic amines in whey samples using a new solid phase extraction method prior to their analysis by HPLC-MS/MS
    Mirzaei, Hamid
    Mogaddam, Mohammad Reza Afshar
    Khandaghi, Jalil
    MICROCHEMICAL JOURNAL, 2022, 177
  • [3] Analysis of naphthenic acids in aqueous solution using HPLC-MS/MS
    Wang, Xiaomeng
    Kasperski, Kim L.
    ANALYTICAL METHODS, 2010, 2 (11) : 1715 - 1722
  • [4] Determination of octreotide in human serum by HPLC-MS/MS with solid-phase extraction
    Capron, A.
    Destree, J.
    Wallemacq, P.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 559 - 559
  • [5] Dispersive micro solid phase extraction of busulfan from plasma samples using novel mesoporous sorbent prior to determination by HPLC-MS/MS
    Jahed, Fatemeh Soghra
    Hamidi, Samin
    Ghaffary, Saba
    Nejati, Babak
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1145 (1145):
  • [6] Determination of Chloramphenicol in Honey with Automated Solid-Phase Extraction and HPLC-MS/MS Detection
    Wollseifen, Hans Rainer
    Brand, Johannes
    Lambrecht, Detlef
    LC GC EUROPE, 2017, 30 (12) : 694 - 695
  • [7] Determination of Midazolam in Animal Tissues by Solid-Phase Extraction HPLC-MS/MS Method
    Zhao, Jianyuan
    Zhao, Yan
    Yang, Shuming
    Zhang, Bin
    Wei, Tao
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (16) : 5235 - 5238
  • [8] Rapid and automated on-line solid phase extraction HPLC-MS/MS with peak focusing for the determination of ochratoxin A in wine samples
    Campone, Luca
    Piccinelli, Anna Lisa
    Celano, Rita
    Pagano, Imma
    Russo, Mariateresa
    Rastrelli, Luca
    FOOD CHEMISTRY, 2018, 244 : 128 - 135
  • [9] Development and Validation of HPLC-MS/MS Method for Rivaroxaban Quantitation in Human Plasma using Solid Phase Extraction Procedure
    Reddy, G. Srinivas
    Reddy, S. L. N. Prasad
    Reddy, L. Shiva Kumar
    ORIENTAL JOURNAL OF CHEMISTRY, 2016, 32 (02) : 1145 - 1154
  • [10] HPLC-MS/MS analysis of steroid hormones in environmental water samples
    Avar, P.
    Maasz, G.
    Takacs, P.
    Lovas, S.
    Zrinyi, Z.
    Svigruha, R.
    Takatsy, A.
    Toth, L. G.
    Pirger, Z.
    DRUG TESTING AND ANALYSIS, 2016, 8 (01) : 124 - 128