Discrimination of Methylammonium from Organic Ammonium Ions Using Ion-Selective Electrodes Based on Calix[4]arene-crown-6 Conjugates

被引:0
|
作者
Takashi Katsu
Maki Matsumoto
机构
[1] Okayama University,Faculty of Pharmaceutical Sciences
来源
Analytical Sciences | 2001年 / 17卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Calix[4]-bis-2,3-naphtho-crown-6 can be used to discriminate between methylammonium and other organic ammonium ions. An electrode based on this ionophore, potassium tetrakis(p-chlorophenyl)borate (20 mol% relative to the ionophore) as an ionic additive and bis(2-ethylhexyl) sebacate as a solvent mediator in a poly(vinyl chloride) membrane matrix, displayed higher selectivity for methylammonium than for various other organic ammonium ions. However, there was considerable interference by inorganic cations, especially Cs+. Similar calix[4]arene-crown-6 conjugates, such as calix[4]-bis-1,2-benzo-crown-6, calix[4]-bis-crown-6, 1,3-dioctyloxy-calix[4]arene-crown-6, 1,3-diisopropoxy-calix[4]arene-crown-6 and 1,3-dimethoxy-calix[4]arene-crown-6 were less effective in discriminating methylammonium.
引用
收藏
页码:721 / 725
页数:4
相关论文
共 50 条
  • [31] Hydrogen Ion-Selective Poly(vinyl chloride) Membrane Electrode Based on a Calix[4]arene
    Demet Kuruoğlu
    Esin Canel
    Shahabuddin Memon
    Mustafa Yilmaz
    Esma Kiliç
    Analytical Sciences, 2003, 19 : 217 - 221
  • [32] Development of process chemistry for the removal of cesium from acidic nuclear waste by calix[4]arene-crown-6 ethers.
    Bonnesen, PV
    Haverlock, TJ
    Engle, NL
    Sachleben, RA
    Moyer, BA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U938 - U938
  • [33] Lower rim substituted tert-butyl calix[4]arene (part VII):: Ionophoric properties of calix[4]arene-crown-6 derivatives in plasticized PVC-membrane electrodes and in solution
    Bochenska, M
    Zielinska, A
    Pomecko, R
    Hubscher-Bruder, V
    Arnaud-Neu, F
    JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2005, 52 (1-2) : 129 - 134
  • [34] ION-SELECTIVE ELECTRODES BASED ON CALIX[4]ARENE TETRAESTER IN THE DETERMINATION OF FORMALDEHYDE VIA IN-SITU GENERATION OF IONIC LIPOPHILIC HYDRAZONE
    CHAN, WH
    YUAN, R
    ANALYST, 1995, 120 (04) : 1055 - 1058
  • [35] Potassium ion-selective optodes based on the calix[6]arene hexaester and application in human serum assay
    Chan, WH
    Lee, AWM
    Kwong, DWJ
    Tam, WL
    Wang, KM
    ANALYST, 1996, 121 (04) : 531 - 534
  • [36] New cesium ion-selective PVC membrane electrode based on a novel calix[6]arene derivative
    Aslan, N.
    Canel, E.
    Yilmaz, M.
    Kilic, E.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2011, 43 (04): : 526 - 531
  • [37] Organic ammonium ion-selective electrodes using acyclic neutral carriers developed for inorganic cation-selective electrodes
    Katsu, T
    Nishimura, N
    ANALYTICAL SCIENCES, 2000, 16 (05) : 523 - 525
  • [38] Organic Ammonium Ion-Selective Electrodes Using Acyclic Neutral Carriers Developed for Inorganic Cation-Selective Electrodes
    Takashi Katsu
    Nozomi Nishimura
    Analytical Sciences, 2000, 16 : 523 - 525
  • [39] Synthesis of a tweezer-like bis(phenylthiapropoxy)calix[4]arene as a cation/π enhanced sensor for ion-selective electrodes
    Sun, H
    Zeng, XS
    Lü, JQ
    Leng, XB
    Chen, QF
    Xu, FB
    Li, QS
    He, XW
    Zhang, WQ
    Zhang, ZZ
    CHINESE JOURNAL OF CHEMISTRY, 2002, 20 (10) : 1109 - 1114
  • [40] Synthesis of a Tweezer-like Bis(phenylthiapropoxy)calix[4]-arene as a Cation/π Enhanced Sensor for Ion-Selective Electrodes
    孙浩
    曾宪顺
    吕监泉
    冷雪冰
    陈企发
    徐风波
    李庆山
    何锡文
    张文勤
    张正之
    Chinese Journal of Chemistry, 2002, (10) : 1109 - 1114