Discrimination of Methylammonium from Organic Ammonium Ions Using Ion-Selective Electrodes Based on Calix[4]arene-crown-6 Conjugates

被引:0
|
作者
Takashi Katsu
Maki Matsumoto
机构
[1] Okayama University,Faculty of Pharmaceutical Sciences
来源
Analytical Sciences | 2001年 / 17卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Calix[4]-bis-2,3-naphtho-crown-6 can be used to discriminate between methylammonium and other organic ammonium ions. An electrode based on this ionophore, potassium tetrakis(p-chlorophenyl)borate (20 mol% relative to the ionophore) as an ionic additive and bis(2-ethylhexyl) sebacate as a solvent mediator in a poly(vinyl chloride) membrane matrix, displayed higher selectivity for methylammonium than for various other organic ammonium ions. However, there was considerable interference by inorganic cations, especially Cs+. Similar calix[4]arene-crown-6 conjugates, such as calix[4]-bis-1,2-benzo-crown-6, calix[4]-bis-crown-6, 1,3-dioctyloxy-calix[4]arene-crown-6, 1,3-diisopropoxy-calix[4]arene-crown-6 and 1,3-dimethoxy-calix[4]arene-crown-6 were less effective in discriminating methylammonium.
引用
收藏
页码:721 / 725
页数:4
相关论文
共 50 条
  • [41] Selective carrier-mediated cesium transport through polymer inclusion membranes by calix[4]arene-crown-6 carriers from complex aqueous mixtures
    Levitskaia, TG
    Lamb, JD
    Fox, KL
    Moyer, BA
    RADIOCHIMICA ACTA, 2002, 90 (01) : 43 - 52
  • [42] Selective recognition of quaternary ammonium ions and zwitterions by using a biomimetic bis-calix[6]arene-based receptor
    Moerkerke, Steven
    Malytskyi, Volodymyr
    Marcelis, Lionel
    Wouters, Johan
    Jabin, Ivan
    ORGANIC & BIOMOLECULAR CHEMISTRY, 2017, 15 (42) : 8967 - 8974
  • [44] Lead versus cadmium selectivity of ion selective electrodes based on thiophosphorylated calix[6]arene ionophores
    Wroblewski, W
    Brzozka, Z
    Janssen, RG
    Verboom, W
    Reinhoudt, DN
    NEW JOURNAL OF CHEMISTRY, 1996, 20 (04) : 419 - 426
  • [45] Recovery of radio-cesium from actual high level liquid waste using solvents containing calix[4]arene-crown-6 ligands
    Jagasia, P.
    Dhami, P. S.
    Mohapatra, P. K.
    Ansari, S. A.
    Jadhav, S. Y.
    Kalyankar, G. K.
    Gandhi, P. M.
    Kharul, U. K.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2017, 5 (04): : 4134 - 4140
  • [46] Novel monohydrogenphosphate ion-selective polymeric membrane sensor based on phenyl urea substituted calix[4]arene
    Modi, Nishith R.
    Patel, Bhargav
    Patel, Manishkumar B.
    Menon, Shobhana K.
    TALANTA, 2011, 86 : 121 - 127
  • [47] ON THE SELECTION OF THE OPTIMAL PLASTICIZER FOR CALIX[N]ARENE-BASED ION-SELECTIVE ELECTRODES - POSSIBLE CORRELATION BETWEEN THE ION SELECTIVITY AND THE SOFTNESS OF THE PLASTICIZER
    SAKAKI, T
    HARADA, T
    KAWAHARA, Y
    SHINKAI, S
    JOURNAL OF INCLUSION PHENOMENA AND MOLECULAR RECOGNITION IN CHEMISTRY, 1994, 17 (04): : 377 - 392
  • [48] Cs/K selectivity of a lipophilic calix[4]arene-crown-6 extractant in liquid-liquid separations from nitrate media.
    Haverlock, TJ
    Bonnesen, PV
    Sachleben, RA
    Moyer, BA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 2 - IEC
  • [49] Crown-6-calix[4]arene-capped calix[4]pyrrole: An ion-pair receptor for solvent-separated CsF ions
    Sessler, Jonathan L.
    Kim, Sung Kuk
    Gross, Dustin E.
    Lee, Chang-Hee
    Kim, Jong Seung
    Lynch, Vincent M.
    Journal of the American Chemical Society, 2008, 130 (39): : 13162 - 13166
  • [50] Crown-6-calix[4]arene-capped calix[4]pyrrole: An ion-pair receptor for solvent-separated CsF ions
    Sessler, Jonathan L.
    Kim, Sung Kuk
    Gross, Dustin E.
    Lee, Chang-Hee
    Kim, Jong Seung
    Lynch, Vincent M.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (39) : 13162 - 13166